My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
KLB Construction, LLC 4/21/2026 (2)
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
KLB Construction, LLC 4/21/2026 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2026 1:43:27 PM
Creation date
4/21/2026 1:34:43 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
KLB Construction, LLC
Approval Date
4/21/2026
Council Approval Date
4/8/2026
Department
Public Works
Department Project Manager
Randy Loveless
Subject / Project Title
PGSF West Marine View Drive Storm and Combined Sewer, Package 2 Volume 2
Public Works WO Number
UP3815-02
Tracking Number
0005222
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
469
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
PGSF WMVD Storm and Combined Sewer - Construction Package 2 Cast-in-Place Concrete <br />Project No. 180162 03 30 00 - 9 <br /> <br />3. Provide concrete mix designs in accordance with the following guidelines: <br /> <br />Concrete <br />class <br />Minimuma <br />28-day <br />compressive <br />strength, psi <br />ASTM coarse <br />aggregate <br />size <br />Maximum <br />water- <br />cementitious <br />materials <br />(w/cm) ratio <br />Minimum <br />cementitious <br />materials <br />content <br />(pounds/CY) <br />Pozzolan, <br />percent by <br />weight of <br />cementitious <br />materials <br />Air content <br />(percent) <br />Slump <br />rangef <br />(inches) <br />Max Density <br />(pcf) <br />Bc 3000 57 or 67 0.45 560 15-25d 4-6 3-5 - <br />C-1 4500 57 or 67 0.40 560 15-25 4-6 3-5 - <br />C-2 5000 57 or 67 0.42 560 15-25d 4-6 3-5] - <br />E 2000 57 -- - 15-25d Not Required 4-8 - <br />G 5000 67 0.45 660 15-40 Not Required 6-9g - <br />a Determine compressive strength at the end of 28 days based on test cylinders made and tested in accordance with <br />ASTM C39. <br />b Compressive strength of Class A concrete may be determined at 56 days. <br />c Concrete encasement for electrical conduit shall contain 3 pounds of red oxide per sack of cement. <br />d Pozzolan use is optional for this class of concrete. <br />e Minimum 28-day compressive strength shall be 500 psi and maximum 28-day compressive strength shall be 1,000 psi. <br />f Slump before addition of high range water reducing admixture (superplasticizer). Maximum slump after addition of high <br />range water reducing admixture shall be 8”. <br />g Do not use high-range water reducing admixtures for Class G concrete. <br />B. Use: <br />1. Provide concrete by class for the uses listed below. <br /> <br />Concrete class Type of use <br />B Non-structural concrete (sidewalks, curbs, pavers, etc.), electrical conduit encasement (duct banks). <br />C-1 Typical cast-in-place structural concrete <br />C-2 Precast concrete <br />Ea Pipe bedding and encasement and concrete fill <br />G Tremie slab concrete <br />a Contractor’s option to use the same concrete mix for pipe encasement as the concrete slab above. <br />C. Control Tests: <br />1. General: <br />a. Select and adjust proportions of ingredients in accordance with ACI 211.1. <br />Verification of mix characteristics for submittal may be achieved using either the <br />Trial Mix Design method or Field Experience Data method. Do not place concrete <br />prior to submittal and acceptance of proposed mix.
The URL can be used to link to this page
Your browser does not support the video tag.