My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
KLB Construction, LLC 4/21/2026 (3)
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
KLB Construction, LLC 4/21/2026 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2026 2:02:45 PM
Creation date
4/21/2026 1:47:14 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
KLB Construction, LLC
Approval Date
4/21/2026
Council Approval Date
4/8/2026
Department
Public Works
Department Project Manager
Randy Loveless
Subject / Project Title
PGSF West Marine View Drive Storm and Combined Sewer, Package 2 Volume 3
Public Works WO Number
UP3815-02
Tracking Number
0005222
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
PLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPL405 <br />406 <br />29051900201000 <br />UNKNOWN <br />29051900200900 <br />UNKNOWN 29051900201100 UNKNOWNEASEMENT AFN 201907310975 XXXXXXXXXXXXXXX20 <br />20 <br />21 <br />21 <br />20 <br />1 <br />9 <br />21 <br />21 <br />22 <br />EX 16" W DIP <br />TO REMAIN IN SERVICE <br />ROW PERMIT #236,371 <br />DATED JANUARY 1, 1981 <br />EX 10" W CI EX 12" W <br />F <br />CD-2605 <br />EX 32" SS PEP <br />IE=-58.4± <br />W W W W W W W W W W <br />W W W <br />W <br />WW <br />7.85' ℄ TO ℄30' BNSF SETBACK <br />6+00 7+008+009+0010+002 <br />5 5 <br />2 <br />STA. 6+01.94 <br />N:362864.54 <br />E:1302138.16 <br />6 <br />STA. 8+84.87 <br />N:363144.04 <br />E:1302182.07 <br />7 <br />STA. 9+19.68 <br />N:363178.45 <br />E:1302187.38 <br />8 <br />PORT OF EVERETT <br />NORTON TERMINAL <br />EX 12" SS CONC <br />EX 10" W <br />MAINTAIN <br />IN SERVICE <br />EX 10" W <br />EX 10" W CI2 EX 10" W CI 2 <br />TEMPORARY <br />FLUSHING <br />ASSEMBLY <br />4 <br />EX 12" W REMOVE <br />AND REPLACE 6 <br />PE AREA 4 <br />TCE AREA 3 <br />TCE AREA 2 <br />TCE AREA 2 <br />PE AREA 5 <br />?Surveyed By # Date # Control Monument # City of Everett Field Book/Starting Page # / ###Filepath\FilenameC:\USERS\TFRANKLIN\DC\ACCDOCS\BC ACC PROJECT HUB\103977 - EVERETT CONVEYANCE PACKAGES A_C_E\PROJECT FILES\300 DESIGN\UP3815-02\CAD\002 C\SHEETS\3815-02-C-2062.DWGPlot date 12/8/2025 10:38 AM Plotted by Travis Franklin Last saved by TFranklin Plot style Everett-2016.stb Sheetset Name ####################### <br />10 402020FEET0 <br />CIVIL <br />UTILITY RELOCATION PLAN - 3 <br />C-2062 <br />24 <br />R. DAVIES <br />T. FRANKLIN <br />K. WEBER <br />PLAN <br />SCALE: 1"=20" <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER STORAGE FACILITY <br />WEST MARINE VIEW DRIVE <br />STORM AND COMBINED SEWER DESIGN <br />WORK ORDER UP3815-02 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />142RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PRELIMINARY44572 <br /> MATCHLINESEE DRAWING C-2061Know what's below. <br />before you dig.Call <br />R MATCHLINE SEE DRAWING C-2063GENERAL NOTES <br />WATER CONSTRUCTION NOTES <br />WATER KEY NOTES <br />1.THE EXISTING UNDERGROUND UTILITIES SHOWN <br />HEREIN ARE APPROXIMATE LOCATIONS ONLY BASED <br />ON THE FIELD LOCATION OF UTILITY LOCATE PAINT <br />MARKS AND PHYSICAL FEATURES VISIBLE ON OR <br />ABOVE THE GROUND SURFACE. THE CONTRACTOR <br />SHALL DETERMINE THE LOCATION OF ANY AND ALL <br />UNDERGROUND UTILITIES BEFORE BEGINNING WORK. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY <br />AND ALL DAMAGES ARISING OUT OF THEIR FAILURE <br />TO EXACTLY LOCATE AND PROTECT ALL EXISTING <br />UTILITY FACILITIES. <br />2.WORK AROUND POWER AND GAS UTILITIES MUST BE <br />PERFORMED IN ACCORDANCE WITH PSE AND SNOPUD <br />REQUIREMENTS. COORDINATE CONSTRUCTION <br />ACTIVITIES AND SCHEDULE WITH UTILITY OWNERS. <br />SEE SECTION 02 01 10 AND SECTION 02 01 20. <br />3.EXISTING WATER LINE CAN BE REMOVED FROM <br />SERVICE DURING INSTALLATION PER SECTION 01 12 16 <br />AND SECTION 02 01 10 SOUTH OF THE PGSF FACILITY. <br />MAINTAIN WATER SERVICE AT THE PGSF FACILITY AND <br />TO THE NORTH AT ALL TIMES. <br />1 CONNECT TO EXISTING WATER MAIN IN ACCORDANCE <br />WITH SECTION 02 01 10. POTHOLE LOCATION PRIOR TO <br />PROCUREMENT OF FITTINGS AND COUPLINGS. <br />CONNECTION TO EXISTING WATER LINES MUST BE BY <br />COE FORCES. SEE C-2034. <br />2 DEMOLISH EX 10" AND 16" W AND ALL <br />APPURTENANCES. REMOVE IN ITS ENTIRETY. REPLACE <br />WITH DI W PER COE REQUIREMENTS. <br />4 PROVIDE FLUSHING ASSEMBLY DURING WATER <br />OUTAGE FOR COE FORCES TO FLUSH PIPELINES. <br />PROVIDE ASSEMBLY IN ACCORDANCE WITH COE DETAIL <br />511 MODIFIED AS FOLLOWS. PROVIDE INSERTION <br />VALVE OF EQUAL DIAMETER TO EXISTING WATER <br />SERVICE WITH TEMPORARY REDUCER AND 8-INCH <br />BLOW OFF PIPING. ALL PIPE AND APPURTENANCES TO <br />BE MECHANICALLY RESTRAINED. REMOVE ASSEMBLY <br />AND SALVAGE TO CITY DURING FINAL CONNECTION TO <br />RELOCATED WATER LINE. LOCATION OF THE ASSEMBLY <br />TO BE COORDINATED WITH THE CITY. PROVIDE VALVE <br />ANCHOR/SUPPORT. <br />5 ABANDON PIPE AND APPURTENANCES IN PLACE <br />WITHIN THE BNSF SET BACK. CUT AND CAP PIPE TO <br />REMAIN IN PLACE. PROVIDE THE SURVEYED LOCATION <br />OF THE CUT AND CAPPED PIPE ENDS ON RECORD <br />DRAWINGS. <br />6 REMOVE AND REPLACE EX W. PROVIDE DIP W PER COE <br />REQUIREMENTS. EXTENTS TO BE COORDINATED WITH <br />THE COE. <br />6 APPROX STA. 6+02 PROVIDE: <br />(1)POTHOLE LOCATION PER WATER CONSTRUCTION <br />NOTE 1. <br />(1)CONNECT TO EX 16" W. <br />(1)16" ISOLATION VALVE AND EXTENSION PER COE <br />DETAIL 511. <br />(1) 16" DI 90° BEND. TURN FITTING TO MAKE <br />HORIZONTAL AND VERTICAL ALIGNMENT. <br />7 APPROX STA. 8+85 PROVIDE: <br />(1)POTHOLE LOCATION PER WATER CONSTRUCTION <br />NOTE 1. <br />(1)CONNECT TO EX 10" W. PROVIDE 10" DI SPOOL AS <br />REQUIRED. FIELD VERIFY LENGTH. <br />(1)PROVIDE FLUSHING ASSEMBLY PER WATER <br />CONSTRUCTION NOTE 4. <br />(1)16"X16"10" DI TEE. TURN FITTING TO MAKE <br />HORIZONTAL AND VERTICAL ALIGNMENT. <br />(1)10" ISOLATION VALVE AND EXTENSION PER COE <br />DETAIL 511. <br />(1) CONNECT TO EX 10" W. <br />8 APPROX STA. 9+20 PROVIDE: <br />(1) POTHOLE LOCATION PER WATER CONSTRUCTION <br />NOTE 1. <br />(1) CONNECT TO EX 12" W. PROVIDE 12" DI SPOOL AS <br />REQUIRED. FIELD VERIFY LENGTH . <br />(1) 16"X16"12" DI TEE. TURN FITTING TO MAKE <br />HORIZONTAL AND VERTICAL ALIGNMENT. <br />(1) 12" ISOLATION VALVE AND EXTENSION PER COE <br />DETAIL 511. <br />12/09/2025