Laserfiche WebLink
PLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPL101102 <br />106 <br />112 <br />500 <br />29051900201500 <br />UNKNOWN <br />29051900201300 <br />2600 FEDERAL AVE <br />EASEMENT AFN 201907310975 <br />XXXXXXXXXXXXXX19 <br />18 <br />191820 <br />21 1817 <br />19 <br />EX 12" SS CONC EX 12" SS CONC <br />EX 6" HPG <br />G <br />CD-2605 <br />EX 12" W DI <br />EX 12" SS CONC <br />EX 32" SS PEP <br />IE = -56.0± <br />EX 32" SS PEP <br />IE = -52.7± <br />W W W W WW <br />W W <br />7.85' ℄ TO ℄11+0011+919 <br />12 <br />10 <br />11 <br />STA. 11+57.74 <br />N:363412.95 <br />E:1302228.33 <br />STA. 11+82.69 <br />N:363417.39 <br />E:1302203.782 <br />PORT OF EVERETT <br />NORTON TERMINAL <br />7 <br />STA. 12+00.00 <br />N:363720.44 <br />E:1302239.72 12+0013 <br />TEMPORARY <br />FLUSHING <br />ASSEMBLY <br />4 <br />1 <br />PE AREA 5 <br />TCE AREA 2 <br />?Surveyed By # Date # Control Monument # City of Everett Field Book/Starting Page # / ###Filepath\FilenameC:\USERS\TFRANKLIN\DC\ACCDOCS\BC ACC PROJECT HUB\103977 - EVERETT CONVEYANCE PACKAGES A_C_E\PROJECT FILES\300 DESIGN\UP3815-02\CAD\002 C\SHEETS\3815-02-C-2063.DWGPlot date 12/8/2025 10:38 AM Plotted by Travis Franklin Last saved by TFranklin Plot style Everett-2016.stb Sheetset Name ####################### <br />10 402020FEET0 <br />CIVIL <br />UTILITY RELOCATION PLAN - 4 <br />C-2063 <br />25 <br />R. DAVIES <br />T. FRANKLIN <br />K. WEBER <br />PLAN <br />SCALE: 1"=20" <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER STORAGE FACILITY <br />WEST MARINE VIEW DRIVE <br />STORM AND COMBINED SEWER DESIGN <br />WORK ORDER UP3815-02 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />142RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PRELIMINARY44572 <br /> MATCHLINESEE DRAWING C-2062Know what's below. <br />before you dig.Call <br />R <br />GENERAL NOTES <br />WATER CONSTRUCTION NOTES <br />WATER KEY NOTES <br />1.THE EXISTING UNDERGROUND UTILITIES SHOWN <br />HEREIN ARE APPROXIMATE LOCATIONS ONLY BASED <br />ON THE FIELD LOCATION OF UTILITY LOCATE PAINT <br />MARKS AND PHYSICAL FEATURES VISIBLE ON OR <br />ABOVE THE GROUND SURFACE. THE CONTRACTOR <br />SHALL DETERMINE THE LOCATION OF ANY AND ALL <br />UNDERGROUND UTILITIES BEFORE BEGINNING WORK. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY <br />AND ALL DAMAGES ARISING OUT OF THEIR FAILURE <br />TO EXACTLY LOCATE AND PROTECT ALL EXISTING <br />UTILITY FACILITIES. <br />2.WORK AROUND POWER AND GAS UTILITIES MUST BE <br />PERFORMED IN ACCORDANCE WITH PSE AND SNOPUD <br />REQUIREMENTS. COORDINATE CONSTRUCTION <br />ACTIVITIES AND SCHEDULE WITH UTILITY OWNERS. <br />SEE SECTION 02 01 10 AND SECTION 02 01 20. <br />3.EXISTING WATER LINE CAN BE REMOVED FROM <br />SERVICE DURING INSTALLATION PER SECTION 01 12 16 <br />AND SECTION 02 01 10 SOUTH OF THE PGSF FACILITY. <br />MAINTAIN WATER SERVICE AT THE PGSF FACILITY AND <br />TO THE NORTH AT ALL TIMES. <br />1 CONNECT TO EXISTING WATER MAIN IN ACCORDANCE <br />WITH SECTION 02 01 10. POTHOLE LOCATION PRIOR TO <br />PROCUREMENT OF FITTINGS AND COUPLINGS. <br />CONNECTION TO EXISTING WATER LINES MUST BE BY <br />COE FORCES. SEE C-2034. <br />2 DEMOLISH EX 16" W AND ALL APPURTENANCES. <br />REMOVE IN ITS ENTIRETY. REPLACE WITH DI W PER COE <br />REQUIREMENTS. <br />4 PROVIDE FLUSHING ASSEMBLY DURING WATER OUTAGE <br />FOR COE FORCES TO FLUSH PIPELINES. PROVIDE <br />ASSEMBLY IN ACCORDANCE WITH COE DETAIL 511 <br />MODIFIED AS FOLLOWS. PROVIDE INSERTION VALVE OF <br />EQUAL DIAMETER TO EXISTING WATER SERVICE WITH <br />TEMPORARY REDUCER AND 8-INCH BLOW OFF PIPING. <br />ALL PIPE AND APPURTENANCES TO BE MECHANICALLY <br />RESTRAINED. REMOVE ASSEMBLY AND SALVAGE TO CITY <br />DURING FINAL CONNECTION TO RELOCATED WATER <br />LINE. LOCATION OF THE ASSEMBLY TO BE COORDINATED <br />WITH THE CITY. PROVIDE VALVE ANCHOR/SUPPORT. <br />7 PROVIDE ISOLATION GATE VALVE PER WATER KEYNOTE <br />12 PRIOR TO WATER OUTAGE. MAINTAIN SERVICE TO <br />THE NORTH AT ALL TIMES. <br />9 APPROX STA. 11+58 PROVIDE: <br />(1) 16"X16"X16" DI TEE. TURN FITTING TO MAKE AND <br />VERTICAL ALIGNMENT. <br />(1) 16" ISOLATION VALVE AND EXTENSION PER COE <br />DETAIL 511. <br />10 APPROX STA. 11+58 PROVIDE: <br />(1) 16" DI REDUCER <br />(1) BLOW OFF PER COE DETAIL 511 <br />11 APPROX STA. 11+83 PROVIDE: <br />(1) POTHOLE LOCATION PER WATER CONSTRUCTION <br />NOTE 1. <br />(1) CONNECT TO EX 12" W. PROVIDE 12" W DI <br />SPOOL AND FITTING AS REQUIRED. FIELD VERIFY <br />LENGTH. <br />(1) DEMOLISH EXISTING VALVE <br />(1) 12" ISOLATION VALVE AND EXTENSION PER COE <br />DETAIL 511. <br />(1) PROVIDE FLUSHING ASSEMBLY PER WATER KEY <br />NOTE 4. <br />(1) CONNECT TO EX 12" W <br />12 APPROX STA. 11+90 PROVIDE: <br />(1) POTHOLE LOCATION PER WATER CONSTRUCTION <br />NOTE 1. <br />(1) CONNECT TO EX 16" W. <br />(1) 16" ISOLATION VALVE AND EXTENSION PER COE <br />DETAIL 511. <br />(1) 16"X16"X16" DI TEE. TURN FITTING TO MAKE <br />VERTICAL ALIGNMENT. <br />13 APPROX STA. 12+00 PROVIDE: <br />(1)POTHOLE LOCATION PER WATER CONSTRUCTION <br />NOTE 1. <br />(1)CONNECT TO EX 16" W.MATCHLINESEE DRAWING C-206412/09/2025