Laserfiche WebLink
City of Everett 00 22 13 - 1 <br />PGSF WMVD Storm and Combined Sewer - Construction Package 2 WO# UP-3815-02 <br />00 22 13 - 1 SUPPLEMENTAL INSTRUCTIONS TO BIDDERS <br />SECTION 00 22 13 <br />SUPPLEMENTAL INSTRUCTIONS TO BIDDERS <br />PART 1 - GENERAL <br />1.1 GENERAL <br />A. It is the intent of City to award a contract to the lowest responsive and responsible <br />Bidder. Before award, the Bidder must also meet the supplemental bidder responsibility <br />criteria listed below. Further, the apparent low Bidder and second apparent low bidder <br />must submit the Bidder Qualification Statement (Section 00 45 13) and any other <br />documentation listed below to the City within one business day after the bid opening, <br />unless the City’s project manager, in writing, allows additional time. The City reserves <br />the right to require such documentation from other bidders also. <br />1.2 SUPPLEMENTAL RESPONSIBILITY CRITERIA <br />A. Experience <br />1. Criteria: The Bidder must satisfy criteria a, b, and c below: <br />a. The Bidder must have successfully completed at minimum all of the following <br />within ten (10) years prior to bid opening: <br />(1) Three projects involving the construction of at least 1,000 continuous <br />linear feet of buried stormwater or municipal wastewater pipeline having a <br />minimum diameter of 30 inches and reaching a depth of at least 15 feet <br />for the invert elevation for portions of the pipeline. This construction may <br />have been by Bidder’s own forces or by subcontractor(s). Three separate <br />Bidder projects must be used to satisfy this requirement. <br />(2) Three trenchless pipeline installations using pipe ramming, jacking, or <br />microtunneling methods for stormwater or municipal wastewater <br />conveyance pipelines with a carrier pipe diameter of at least 30 inches. <br />This construction may have been by Bidder’s own forces or by <br />subcontractor(s). At least two separate Bidder projects must be used to <br />satisfy this requirement. <br />Alternative. If the Bidder does not have trenchless pipeline <br />installation projects to satisfy the preceding requirement, then <br />Bidder may alternatively satisfy requirement (2) if the Bidder’s <br />selected trenchless pipeline construction specialty subcontractor <br />for the Project has successfully completed the three trenchless <br />pipeline installations using pipe ramming, jacking, or <br />microtunneling methods for stormwater or municipal wastewater <br />conveyance pipelines with a carrier pipe diameter of at least 30 <br />inches within ten (10) years prior to bid opening. At least two <br />separate specialty subcontractor projects must be used to satisfy <br />this alternative requirement. This alternative requirement may not <br />be satisfied by a combination of Bidder and specialty <br />subcontractor projects. If the Bidder uses this alternative