CK Engineering LLC. <br /> STRUCTURAL FRAMING <br /> The existing structure is conventionally built, stick frame,wood structure over a shallow concrete <br /> foundation. The roof structure appears to consist of wood rafters supported along the perimeter <br /> walls and interior bearing walls. In addition, the roof structure above the living room area <br /> appears to be constructed as wood roof rafters with a collar tie assembly.The exterior and interior <br /> walls appear to be constructed from 2x4 wood studs while the floor system appears as a 2x10 <br /> floor joists supported along the interior bearing line and the exterior walls. <br /> Based on provided drawings by RE-VOLVE LLC, and our site review, during the remodeling <br /> interior walls at the kitchen and entry were removed and new exterior deck was added along the <br /> living room/main entry area. <br /> At the time of the site visit, the interior beams were covered with gypsum boards while deck <br /> construction was completed. <br /> CONCLUSIONS <br /> CK Engineering LLC performed gravity calcs to verify structural adequacy of installed members, <br /> marked up the architectural drawings and provided structural connection details. <br /> Our recommendations include following: <br /> Interior remodeling <br /> 1) Roof beam (RF#1), spanning approximately 6'-7" should be a minimum a 4x8 HF#2 <br /> supported with a 2-2x4s at exterior wall and a Simpson Tie hanger HU48 (or similar) at <br /> the other end. <br /> 2) Roof beam (RF#2), spanning approximately 11'-8" should be a minimum a 3 1/8 x 12 <br /> GLB 24F-V4 supported with a 2-2x4s at the exterior wall and a 4x6 HF#2 minimum at <br /> the kitchen area. <br /> 3) Roof beam (RF#3), spanning approximately 11' appears to be parallel with the roof <br /> rafters, therefore not supporting the roof structure serving more as an architectural <br /> component. <br /> 19229 38th PL NE Lake Forest Park,WA 98155 Ph: 206-417-0670 <br />
The URL can be used to link to this page
Your browser does not support the video tag.