Laserfiche WebLink
. Component Perform .ce Path, pg. 2 Zo ,,s 4c/5b ENV-UA <br /> • 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over: Revised Oct 2013 <br /> Project Address Underwood Gartland - Building A Date 05/18/2015 <br /> Fenestration Area as%gross above-grade wall area 7.7% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area 1.3% Max.Target: 5.0% <br /> Notes: 1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target <br /> Area Adjustment of all applicable envelope elements will be calculated by the compliance form. <br /> Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:Provide NFRC rated U-factor or default U-factor from Appendix A for the fenestration assembly <br /> thermal performance(combination of frame and glazing). <br /> 3:Fenestration that separates conditioned space from a non-conditioned or semi-conditioned <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor,page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A) U-factor x Area(A)= UA(U x A) <br /> a N U=0.370 ID:Man Doors 0.370 378 139.9 0.37 378 139.9 <br /> 3 o U= ID: Opaque Swing Doors U-0.37 <br /> (1)0 U= ID: <br /> E U=0.0625 ID:9'x10'(R-16.00) 0.063 3600 225.0 0.37 5034 1862.6 <br /> o U=0.0656 ID:9'x10'w/windows(R-15.25) 0.066 450 29.5 Opaque rollup&sliding U-0.37 <br /> a U=0.1299 ID:16'x16'Rollup(R-7.70) 0.130 256 33.2 <br /> 0 <br /> U=0.0734 ID:12'X14'(R-16.00) 0.063 336 21.0 <br /> Q U=0.0734 ID:14'x14'w/windows(R-15.58) 0.064 392 25.2 <br /> m U= ID: 0.30 1 <br /> t U= ID: Non-Metal Frame U-0.30 <br /> o U= ID: <br /> z U= ID: 1 <br /> g U=0.4 ID:Storefront Fixed 0.40 5179 2071.6 0.38 5179 1968.0 <br /> 4 - U= ID: Metal Frame, Fixed U-0.38 <br /> - ro U= ID: <br /> m <br /> 2 2 U= ID: <br /> m <br /> U a U= ID: 0.40 <br /> To• ° U= ID: Metal Frame,Operable U-0.40 <br /> r <br /> o U= ID: <br /> 2 U= ID: <br /> 8 U=0.68 ID:Entrance 6'x7'&3x7 0.68 231 157.1 0.60 231 138.6 <br /> c <br /> ro U= ID: Metal Entrance Door U-0.60 <br /> o U= ID: <br /> 2 U= ID: <br /> N w U=0.30 ID:Skylight: U=0.30 0.30 2592 777.6 0.50 2592 I 1296.0 <br /> o a U= ID: All types U-0.50 <br /> .r ~ U= ID: s5 z_ -hr . t: s <br /> cn ¢ U= ID: v <br /> Area UA Area UA <br /> Page 2 Subtotal 13414 3480 13414 5405 <br /> To comply: Page 1 Subtotal 260239 16212 260239 14321 <br /> 1)Proposed Total UA shall not exceed Target Total UA. <br /> 2)Proposed Total Area shall equal Target Total Area. Total 273653 19692 273653 19726 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> .14 <br /> J <br />