Laserfiche WebLink
• <br /> COMMSC( PF s ®fl' � • <br /> Installation Instructions on the go BSAMNT MountingKit LANDLORD SIGNATURE Ka <br /> ' <br /> 4, <br /> Mounting Kits For Wide Panel Antennas Bulletin 639825-1 •Revision C•July 2014 Bulletin 639825-1 •Revision C•July 2014 Page 2 of 2 42 I <br /> BSAMNT Series:Mounting systems for cylindrical pipe Page 1 of 2 (Continued from page 1) <br /> installations (60-115mm pipe diameter) for heavy duty applications Andrew Institute offers installation training. OVAL <br /> MAXIMUM TORQUE _1 <br /> ITEM NO. DESCRIPTION QTY U/MI lI I !EXPIRES II'2D/8 I <br /> M10 37N.m(27ft.lbs) I IT IS A VIOLATION OF LAW FOR ANY PERSON.UNLESS THEY <br /> IPIPECLAMP BRACKET,NO FLANGE 2 EA M12 58N.m(43ftlbs) 1 ARE ACTING UNDER THE DIRECTION OF A LICENSED <br /> • ARE <br /> ENGINEER,TO ALTER THIS DOCUMENT. <br /> 2 PIPECLAMP BRACKET,SHORT FLANGES 2 EA ',I M12 bolt <br /> 3 NOTCHED BRACKET 1 EA ,( I /-) • <br /> __ _____________ 2 T ••Mobile•• <br /> .___ ___ <br /> 4 BRACKET 1 EA <br /> 5 SCR,HH,HEX,M8X25,SST,PASS 4 EA 13 i ' <br /> 6 WSHR,LK,SPLT,M8,STL,GALV 4 EA �t - <br /> L ,� � � �-' � 19807 NORTH CREEK PARKWAY NORTH <br /> 7 TWO HOLE PLATE,8mm X 1.25 PITCH 2 EA ;j BOTHELL,WA 98011 <br /> 8 J NUT,HEX,M10,STL,GALV 12 EA <br /> 9 WSHR,LK,SPLT,M10,STL,GALV 6 EA \I - �"-' YS <br /> 10 SCR,HCS,HEX,M10X40,STL,GALV 6 EA t_' e ' 11,.,. <br /> ATTENTION:Insert M12 bolts and M12 Technology Associates <br /> 11 NUT,HEX,MI2,STL,GALV 8 EA ,-.Is CO 8 flat washers into bracket with tabs <br /> 12 WSHR,FLT,M12,13X28X2.5,STL,GALV 4 EA _ z prior to attaching bracket to antenna. PNw MARKET OFFICE <br /> 13 WSHR,LK,SPLT,M12,STL,GALV 4 EA M10 bolt 650 SOUTH ORCAS STREET,STE.R-103 <br /> 14 BOLT,CARRIAGE,M 12 X 200,STL,GALV 4 EA SEATTLE,WA 98108 <br /> Part Lists Bottom Mount Installation <br /> r®; Technology4Associates <br /> iImp- 7 — ARCHITECTURE&ENGINEERING <br /> CCev two ole plate. •Loosen pivot bolts.(do ----- -M 10 pivot bolt --M10 pivot bolt 2851 CAMINO DEL RIO SOUTH,STE.200 <br /> '2)0) i)0 le 3 not remove) (loosen only) (loosen only) SAN DIEGO,CA 92108 <br /> 10 <br /> 'kw •Remove adjuster wm bolts. / -M8 adjuster bolt <br /> m' perimeter location <br /> •Adjust antenna angle. 1 I i -- (remove to adjust tilt) <br /> ~ a (use inclinometer) ( I� <br /> SQ O I � J <br /> t .__ �0 p ' / -M10 pivot bolt <br /> M8 bolt Reinstall adjuster bolts, <br /> A (loosen only) as,uxms L70DCMPHX27A%CD MOM <br /> A a•m'x,a L70DCMP44X21111%cD MOM <br /> •Retighten all bolts. I use inclinometer to A mnvm,s SSUEDFOR SS%CDREVIEW GAB <br /> (�� O1 ,l <br /> �` 1 ii adjust antenna angle "" -I• • <br /> 1' �� REV DATE DESCRIPTION BY <br /> I�14-`11_,. / <br /> I • Bracket edges parallel to each other. l I ' SE01688A <br /> I (fully collapsed position) i i 11 <br /> I. 1 ' <br /> IIII 1 ,I i ( 1 EVERETT MALL <br /> ii 1, 11 . � l <br /> QPre-assembly of Downtilt Brackets i. �� 1 PARK <br /> I,- <br /> 1 11 M8 pivot bolt 1_,---- <br /> z � center location 906 SE EVERETT MALL WAY <br /> MAXIMUM TORQUE M10 bolt h (loosen only) - <br /> c M8 15N.m(11 ft,lbsI M10 bolt 000 DETAIL A _ MAXIMUM TORQUE EVERETT,WA 98208 <br /> I M8 15N.m(11ft.lbs) ROOFTOP <br /> ✓ M10 37N.m(27ft.lbs) , Q `i , I <br /> M12 bolt ` M10 pivot bolt <br /> M12 58N.m(43ft.Ibs) j 14 �' --- <br /> M10 37N,m(27ft-lbs) <br /> o <br /> LL (loosen only) <br /> 13Iz �� '+ I M12 58N.m(43ft.lbs) <br /> C� — " i <br /> Adjusting Antenna Tilt <br /> II <br /> g I,li', I � \, SAFETY NOTICE <br /> 14\ ___ / J <br /> • \ IN SAFETY <br /> • The installation,maintenance,or removal of an antenna <br /> KZ *11-1/ ._ ! /!7 2�s ,� requires qualified,experienced personnel.CommScope1 ✓/I Installation Instructions are written for such installation -r <br /> gr ol� C personnel.Antenna systems should be inspected once a �_t 1 <br /> E % year by qualified personnel to verify proper Installation, // — ♦ ©� <br /> I . maintenance,and condition of equipment. r"117;1 �♦ <br /> x JURISDICTION APPROVAL STAMP <br /> W 0' CommScope disclaims any liability or responsibility for the �� __ DEPARTMENT FOR LAND USE <br /> `./ DEPARTMENT FOR BUILDING&CONSTRUCTION <br /> results of improper or unsafe installation practices. <br /> _ Do not install near power fines. Do not install on a we or windy Wear shoes with rubber soles and <br /> SPower lines,telephone lines, day hr when rg htning or thunder hee6.Wea protective cbthirg SHEET TITLE <br /> s r Itis recommended that transmit power be turned off and gay wires waR the same. bin the ares.Da nor DSe metal rubber galong-sleevetl skid and <br /> E when the field installation is performed.Follow all Assume anywve or fine can ladder. abbe gloves. <br /> x I electrocute you. <br /> F. !' applicable safety precautions as shown on this page. ANTENNA MOUNTING <br /> LL ATTENTION:Insert M12 bolts and M12 I CRITICAL:For initial installation <br /> W flat washers Into bracket with tabs to pipe,downtilt brackets must SPECIFICATIONS <br /> prior to attaching bracket to antenna. V-� be configured in pre-assembly <br /> i position(fully collapsed). CommScope www.commscope.comlandrew <br /> i - Customer Support Center Visit our Web site at www.commscope.com or contact your local sales representative for more information. SHEET NUMBER <br /> - North America:+1-800-255.1479,Option 1 e 2012 CommScope,Inc.All rights reserved. <br /> o Top/Middle Mount installations International: +1-779-435.6500,Option 1 Andrew is a trademark of CommScope.All trademarks identified bye or TM are registered trademarks or trademarks, <br /> lu Email: BSASupport©CommScope.com any spcelc,of CommScope.warranties <br /> Thise document t is for products purposes only and is not intended to modify or supplement A.7� any specifications or warranties relating to Andrew products or services. <br /> fci <br /> ANTENNA MOUNTING SPECIFICATIONS NCTSE 1 <br />