Laserfiche WebLink
A <br /> ELECTRICAL GROUNDING SPECIFICATIONS A 1 <br /> 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF I 01. ,{ <br /> THE NATIONAL ELECTRICAL CODE CURRENTLY IN i 1. <br /> EFFECT FOR THE AUTHORITY HAVING r'1�F1 LANDLORD SIGNATURE � , <br /> 04: <br /> JURISDICTION. . + <br /> 2. ALL GROUNDING DEVICES SHALL BE U.L.LISTED y:` '♦\� <br /> FOR THEIR INTENDED USE. f a� �',- '� <br /> 3. GROUND WIRES SHALL BE TINNED#2 AWG BARE '�,♦�'•`�Q7\ ` <br /> SOLID COPPER UNLESS OTHERWISE NOTED. + '�- Q' '� <br /> IeNEW MB AWG FROM ANTENNA © �* 0 <br /> 4. CONNECTIONS OF ALL GROUND WIRES TO THE :AI.' ` TO(E)SECTOR GROUND BAR(TYP.) ® 1 AL <br /> GROUND RING SHALL BE EXOTHERMIC <br /> (CAD-WELDED),UNLESS OTHERWISE NOTED.AND NEW#8 AWG FROM AHLOAak <br /> SHALLUBE URER'S RECOMMENDATIONSD N DAOE WITH TO(,)SECTOR GROUND BAR(TYP.) I EXPIRES 1112,,018 1 <br /> MANUFACTURER'DUCTRSSHALL BE <br /> ` <br /> T-MOBILE WIRELESS BROADBAND STANDARDS. \\ IT Is A VIOLATION OF LAW FOR NW PERSON,UNLESS THEY <br /> 5. GROUNDING CONDUCTORS SHALL BE ROUTED ��'+ ARE ACTING UNDER THE DIRECTION OF ALICENSED <br /> ALONG THE SHORTEST AND STRAIGHTEST PATH �.•`4 PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. <br /> POSSIBLE.WHEN REQUIRED,GROUND LEADS <br /> ��. /y <br /> SHALL BE BENT TO A MINIMUM OF 8"RADIUS. \ ��(�. /� <br /> 8. WHERE GROUND WIRES ARE ROUTED FROM ANY i ♦��'Ir''' r...........7L---j <br /> I <br /> CONNECTION ABOVE GRADE TO THE GROUND RING. I\♦. .:4644$1;.'' <br /> T <br /> • <br /> 'Mobile <br /> ■ <br /> INSTALL WIRE IN 3/4"HEAVY WALL LIQUID TIGHT FF° O 1 e <br /> FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5" <br /> BELOW GRADE AND SEAL THE TOP WITH SILICONE 19807 NORTH CREEK PARKWAY NORTH <br /> SEALANT. <br /> r_________H <br /> NEW MECHANICAL BOTHELL,WA 98011 <br /> 7. ALL GROUND BARS SHALL BE TINNED,1/4"COPPER, ®LUG CONNECTION <br /> SECTOR BARS 2",COLLECTOR AND MGB BARS 4", (TYP.) _ <br /> OF SUFFICIENT LENGTH TO ACCOMMODATE ALL P•,'..4, <br /> n_____H----J <br /> REQUIRED CONNECTIONS WITHOUT DOUBLING I _ <br /> LUGS,AND EACH INSTALLED WITH ISOLATORS. �,/.� �`_Q Ai- <br /> TechnologyAssociates <br /> WHEN CONNECTING GROUND BARS(WITHIN 10 . <br /> FEET OF GRADE)DIRECTLY TO THE GROUND RING, �1/,' �" ` . <br /> 2 EA.#2 SCUD DOWNLEADS SHALL BE CAD-WELDED (E)SECTOR GROUND BAR PNW MARKET OFFICE <br /> TO THE GROUND BAR,1 AT EACH OPPOSITE ®(FIELD VERIFY LOCATION) 05O SOUTH ORCA$STREET,STE.R-103 <br /> BOTTOM CORNER,AND EACH SHALL RUN IN 3/4" (TYP) SEATTLE,WA 98108 <br /> HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUITFROM GROUND BAR DOWN TO THE GROUND RING.WHEN CONNECTING SECTOR GROUND BARS,DAISY-CHAIN THE GROUND BARS AND RUN 1 EA.#2 Al AWG STRANDED COPPER WIRE WITH THWNINSULATION FROM THE MIDDLE GROUND BAR TOTechnology' ASSociates <br /> THE GROUND RING AND CAD-WELD TO THE RING. •8. WHEN ATTACHING STRANDED GROUND LEADS TO '4.444 / II;;//. I <br /> ARCHITECTURE&ENGINEERING <br /> THE GROUND BARS,2 HOLE COMPRESSION LUGSFROM AB, 2851 CAMINO DEL RIO SOUTH,$TE.200 <br /> SHALL BE USED,PROTECT WITH WEATHERPROOF ASIA,ABIA,AND CABINET ® SAN DIEGO,CA 92108 <br /> HEAT SHRINK.AND WITH A THIN COAT OF"KOP'R -�-:�/ 4..--— TO GROUND BAR(TYP,) 7 <br /> SHIELD"OR EQUIVALENT PROPERLY APPLIED AND +"}, NEW#6 FROM AMOB, <br /> ATTACHED ONLY WITH STAINLESS STEEL ASIK,AAWGW AND CABINET ak <br /> HARDWARE. C ' Izgy <br /> ' TO(E)GROUND BAR(TYP.) <br /> 9. WHEN GROUNDING EQUIPMENT ENCLOSURES, <br /> PANELS,FRAMES,AND OTHER METAL APPARATUS, - • <br /> 0 0911/2018 LT00CMP441f2100%CD MOM <br /> A#8 AWG STRANDED COPPER WIRE WITH THWN <br /> INSULATION SHALL BE ATTACHED UTILIZING A 2 <br /> HOLE COMPRESSION TYPE LUG,PROTECTED WITH sii rte_ A 04092018 L7000/4114.482 90140D MOM <br /> WEATHERPROOF HEAT A CLEAN AND CORROSION r <br /> n_____70 <br /> FREE METALLIC SURFACE UTILIZING STAINLESS <br /> krill,_ A 04/2//2018 IMBUED FOR 7S90140D EW CMMSTEEL SELF-TAPPING SCREWS AS NOTED IN NOTE REV DATE DESCRIPTION BV <br /> 10 EPARE <br /> 10. PREPARE ALL BONDING SURFACES FOR GROUND <br /> CONNECTIONS BY REMOVING ANY AND ALL PAINT <br /> AND CORROSION TO SHINY METAL.FOLLOWING i S E01688A <br /> Ieyp CAD-WELDED CONNECTIONS TO NON-COPPER ' <br /> 'Y SUT OF ANY <br /> ANTI-OXIDIZING NG PAINTFACES,APPLY ,"COLD GALV"OR i/♦``� <br /> co EQUIVALENT. .�I�♦�` _ EVERETT MALL <br /> ll 1114 1 13 <br /> x 11. GROUND RODS SHALL BE COPPER-CLAD STEEL ♦♦Q iiiii1 _ <br /> n 5/8"x10',SPACED NO LESS THAN 10'ON CENTER. ���`.� ��_ ,-. PARK <br /> O 12. ALL GROUND SYSTEM CONDUCTORS AND `,�� .,% <br /> 3 CONDUITS SHALL BE SECURED UTILIZING ONLY �,' �� AI(E)GROUND BAR(FIELD <br /> z NONMETALLIC,NON-CONDUCTIVE,UV RATED r/- ®VERIFY LOCATION) 906 SE EVERETT MALI.WAY <br /> M CLAMPS,BRACKET,AND OR SUPPORTS. / (TYP) <br /> OB EVERETT,WA 98208 <br /> O 13. WHEN REQUIRED,THE CONTRACTOR SHALL , <br /> E7 <br /> Lia ENGAGE THE SERVICES OF AN INDEPENDENT �'....4° .,,... <br /> ` /V/ <br /> 1 TESTING FIRM TO VERIFY,UTILIZING A MEGGER O/ ©NEW MECHANICAL LUG ROOFTOP <br /> TEST,THAT THE RESISTANCE TO EARTH OF THE ,��f��� �t G�6 ®CONNECTION(TYP.) <br /> re <br /> NEW GROUND SYSTEM IS EQUAL TO ORY OF THE COMPLETE <br /> TELESS THAN `_��. <br /> REPORT SHALL P BE PROVIDED TO THE TESTING-MOBILE �y`4//yr��.,A, G <br /> 7 REPRESENTATIVE �'`'� V�� <br /> p <br /> 0 <br /> F 14. INSTALLEDALL MATERIALS AND HARDWARE SHALL BR <br /> IN A WORKMAN-LIKE MANNER IN `,z,,,:;' ''''.y'� �I <br /> 2 <br /> 8 ACCORDANCE WITH MANUFACTURER'S <br /> RECOMMENDATIONS,AND DEFINED IN NFPA-70 AND Q APPROVED BY A,H,J, <br /> (Di/ <br /> C <br /> J <br /> U <br /> g LEGEND <br /> m <br /> ■ EXOTHERMIC CONNECTION <br /> JURISDICTION APPROVAL STAMP <br /> i3 • MECHANICAL CONNECTION DEPARTMENT FOR LAND USE <br /> DEPARTMENT FOR BUILDING&CONSTRUCTION <br /> 8 <br /> z Faurn9 EQUIPMENT GROUND BAR <br /> SHEET TITLE <br /> ILL IMEI ANTENNA GROUNDBAR(ASREQUIRED) GROUNDING <br /> #2 AWG GROUND LEAD(AS REQUIRED) <br /> LL <br /> uCD PLANS <br /> a NOTE: 1411:0.1% <br /> .1 \�1/ <br /> •I <br /> = 1. CONTRACTOR TO REPLACE ALL MISSING GROUND BARS 1029 <br /> SHEET NUMBER <br /> E AND GROUNDING CONNECTIONS AS REQUIRED. ©►. ©�. <br /> oI <br /> G-1 <br /> NOTES & LEGEND SCALE 1 ANTENNA GROUNDING SCALE 2 EQUIPMENT GROUNDING SCALE <br /> N.T.S. N.T.S. N.T.S. 3 <br />