My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9930 EVERGREEN WAY PAROBA COLLEGE 2016-08-05
>
Address Records
>
EVERGREEN WAY
>
9930
>
PAROBA COLLEGE
>
9930 EVERGREEN WAY PAROBA COLLEGE 2016-08-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2016 8:36:03 AM
Creation date
8/4/2016 1:55:02 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9930
Tenant Name
PAROBA COLLEGE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and>3 story R2 and R3 <br /> Mechanical Summary MECH-SUM <br /> 2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Info Project Address 9930 Evergreen Way Date 11/25/2014 <br /> Everett WA, 98204 For Building Dept.Use. <br /> A C 30t3-PG <br /> Applicant Name: Merit Mechanical <br /> Applicant Address: 9630 153RD Ave NE Redmond WA, 98052 <br /> Applicant Phone: 1-425-883-9224 Extension 1219 <br /> Project Description Replace two existing gas/electric rooftop units with new. <br /> Briefly describe mechanical <br /> system type and features. <br /> Q Includes Plans Drawings must contain notes requiring compliance with commissioning provisions per Section C408 <br /> Compliance Option 0 Simple System Q Complex System Q Systems Analysis <br /> Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on <br /> the plans. For projects without plans,fill in the required information below. <br /> Cooling Equipment Schedule <br /> Equip. Equip Capacity2 OSA CFM SEER Econmizer Heat <br /> ID Type Brand Name' Model No.1 Btu/h or Econo? or EER IPLV3 Option or Recovery <br /> Exceptions Y/N <br /> SEE M0.00 <br /> • <br /> Heating Equipment Schedule <br /> Equip. Equip Capacity2 OSA cfm Heat <br /> ID Type Brand Name1 Model No.1 Btu/h or Econo? Input Btuh Output Btuh Efficiency4 Recovery <br /> Y/N <br /> SEE M0.00 <br /> Fan Equipment Schedule <br /> Equip. Equip <br /> ID Type Brand Name1 Model No.1 CFM Sp1 HP/BHP Flow Controls Location of Service <br /> Service Water Heating Equipment Schedule <br /> Equip. Equip Input Sub <br /> ID Type Brand Name1 Model No.1 Capacity Category EF7 Location of Service <br /> I If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP,HSPF,Combustion Efficiency,or AFUE,as <br /> applicable. 5 Flow control types:variable air volume(VAV),constant volume(CV),or variable speed(VS). 6 Economizer exception number per <br />
The URL can be used to link to this page
Your browser does not support the video tag.