Laserfiche WebLink
Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Address 9930 Evergreen Way Date 11/25/2014 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. NOTE:Define print area in Excel prior to printing MECH-CHK pages. <br /> Applicability Location on Building Department <br /> (yes,no,na) Code Section Code Provision Information Required Plans Notes <br /> GENERAL PROVISIONS <br /> Equipment Sizing&Performance <br /> NA C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per <br /> Chapter 3 <br /> 0403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not <br /> NA sizing exceed calculated loads,note exceptions taken <br /> YES C403.2.5 Minimum ventilation Ventilation(natural or mechanical)provided per IMC;indicate mechanical MO.00 <br /> ventilation is capable of being reduced to minimum requirement per IMC <br /> C403.2.3& Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, <br /> C403.2.3.2& efficiency capacity,efficiency,test standard(or other efficiency source)for all <br /> YES C403.2.12.1 mechanical equipment MO.00 <br /> NA C403.2.13 Electric motor efficiency Provide equipment schedule with hp,rpm,efficiency for all motors;note <br /> except. <br /> NA C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table <br /> C403.2.10.1(1) <br /> NA C403.2.10.3 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency <br /> &C403.2.13 req. <br /> NAMaximum air cooled chiller <br /> C403.2.3 capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit <br /> 0403.2.1 Non-standard water-cooled Full-load and NPLV values for water-cooled centrifugal chiller adjusted for <br /> NA chillers non-standard operational conditions <br /> 0403.2.12.1.2 Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s)meet efficiency <br /> NA towers requirements for axial fan open circuit cooling towers <br /> Forced air furnace and unit <br /> NA C403.2.3 <br /> heaters Indicate intermittent ignition or IID,flue/draft damper&jacket loss <br /> NA C403.2.3.3 Packaged electric <br /> heating/cooling equipment List equipment required to be heat pumps on schedule <br /> NA C403.2.3.4 Humidification Indicate method of humidification(note requirements for systems with <br /> economizer) <br /> HVAC System Controls&Criteria <br /> NA C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans,including <br /> perimeter systems <br /> 0403.2.4.1.1 Heat pump supplementary Indicate staged heating(compression/supplemental)&outdoor lock-out <br /> NA heat temp <br /> YES C403.2.4.2 Setpoint overlap(deadband) Indicate 5°F deadband minimum for systems controlling both heating& MO.00 <br /> cooling <br /> YES C403.2.4.3 Automatic setback and Indicate zone t-stat controls with required automatic setback&manual MO.00 <br /> shutdown override <br /> YES C403.2.4.3.3 Automatic(optimum)start Indicate system controls that adjust equip start time to match load MO.00 <br /> conditions <br /> C402.4.5.2& Dam Indicate location of OSA,exhaust,relief and return air dampers;include <br /> Dampers <br /> YES C403.2.4.4 p AMCA rated leakage and control type(motorized or gravity;note exceptions MO.00 <br /> NA C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls <br /> NA C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions <br /> NA C403.2.4.6 Combustion heating <br /> equipment Indicate modulating or staged control <br /> NA C403.2.4.7 Group R1 hotel/motel Indicate method for guest room automatic setback&set-up of 5°F minimum <br /> systems <br /> NA C403.2.4.8/9 Group R2/R3 dwelling unit Indicate 5-2 programmable thermostats in primary spaces with minimum of <br /> systems two setback periods;note exceptions taken <br /> 0403.2.5.1 <br /> ventilation Demand controlled Indicate high-occupancy spaces and systems requiring DCV <br /> NA <br /> NA C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy-based system control and method;or <br /> alternate means provided to automatically reduce OSA when partially <br /> Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation <br /> NA C403.2.5.3 dock/parking garage ventilation system activation and control method <br /> NA C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air;indicate make-up air source <br /> and conditioning method <br /> Indicate lab exhaust systems requiring heat recovery,method&efficiency; <br /> NA C403.2.5.4.2 Laboratory exhaust systems or alternative method taken(VAV,semi-conditioned makeup,or CERM <br /> calculation) <br /> C403.2.6.1 Energy recovery- Indicate ventilation systems requiring ER,method&efficiency;note <br /> NA ventilation systems exceptions <br /> NA C403.2.6.2 Energy recovery- Indicate on-site steam heating systems requiring energy recovery <br /> condensate systems <br /> NA C403.2.6.3 Energy recovery- <br /> condenser systems Indicate remote refrig.condensers requiring ER and use of captured energy <br />