PUBLIC WORKS <br /> May 17, 2016 <br /> Charles Spoelstra <br /> 4081 Salt Spring Dr <br /> Ferndale, WA 98248 <br /> Property Addresses: 1301 Hewitt Ave, 1307 Hewitt Ave, 1309 Hewitt Ave <br /> Record #: W1605-010 <br /> ACTION: Permit applications required to be submitted to Everett Permit Services for <br /> corrective action <br /> The City of Everett has received a complaint regarding the configuration of the shared parking lot <br /> at the north end of the above three listed property addresses. Our records indicate that these <br /> properties are listed as follows: <br /> C 1301 Hewitt Ave: Retail building on the parcel described as EVERETT PLAT OF BLK <br /> 670 - LOTS 8A & 9 & 10. <br /> a 1307 Hewitt Ave: Restaurant building on the parcel described as EVERETT PLAT OF <br /> BLK 670 - LOT 11 and LOT 12. <br /> • 1309 Hewitt Ave: Welfare and Charitable Services building on the parcel described as <br /> EVERETT PLAT OF BLK 670 - LOT 13. <br /> The City's records indicate that the current parking lot layout and associated striping is in violation <br /> of re-striping without required permits and approvals per EMC13.76.010 (Ord. 898-82) and §1-7 <br /> Design and Construction Standards and Specifications for Development. Further research <br /> indicates that the current layout does not comply with current City of Everett standards, as set forth <br /> in Standard Drawing 334. The specific deficiencies are identified below: <br /> 1. Angled parking configurations in commercial parking lots require a turn-around so that <br /> vehicles do not back onto or off of the public roadway. The current configuration does not <br /> provide a turn-around for vehicles parking in the angled spaces. <br /> 2. The angled parking stalls do not meet minimum dimensions. The angled stalls should be a <br /> minimum of 25.4 feet deep measured along the parking stall restripe (current measurement <br /> 20.0 feet), or 20.1 feet measured at a right angle to the north property line (current <br /> measurement 16 feet). <br /> 3. The head-in 90 degree parking stall adjacent to Grand Ave does not meet minimum <br /> dimensions. The 90 degree parking stalls should be a minimum of 18.5 feet deep measured <br /> along the parking stall stripe (current measurement 16.0 feet) with a minimum drive aisle <br /> width of 28 feet (current measurement is 16 feet). <br /> The following corrective action is required: <br /> A Public Works permit will be required for any site work including restriping of parking stalls, <br /> landscape features, adding or removing of paved surfaces and any required drainage <br /> facilities. The parking stall layout must comply with the City's current Design and <br /> Page 1 of 2 <br />