My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1932 BROADWAY ALTHEAS FOOTWEAR SOLUTIONS 2016-01-01 MF Import
>
Address Records
>
BROADWAY
>
1932
>
ALTHEAS FOOTWEAR SOLUTIONS
>
1932 BROADWAY ALTHEAS FOOTWEAR SOLUTIONS 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 3:46:36 PM
Creation date
8/17/2016 8:54:43 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
1932
Tenant Name
ALTHEAS FOOTWEAR SOLUTIONS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
►-- • . <br /> l4. Egress and emergency lighting should be shown on the drawings, per IBC sedions <br /> 100G.3, lUll.l, and Table 1015.1. <br /> a. A discernible path of egress should be shown with illuminated exit signs on the <br /> drawings, per IBC section 1011.1, where two exits are required. <br /> b. Emergency lighting should be shown on the drawings, per IBC section 1006.1, <br /> where hvo exits are required. <br /> Construction <br /> 1. Door and window schedules should be shovan on the drawings. <br /> /l/1c�P��&'J a. Door widths are minimum 2'-10" per IBC section 1008.1.1. <br /> oN P���'� b. The height of window heads and silis should be shown in elevation. <br /> ��,3,�,, c. New doors shou' ��ave hardware referenced on the drawinys that is operable <br /> d� fa��af" without tight grasping, pinching or hvisting of the vdrist, per IBC sedion <br />_ �y;�r 1008.1.9.1. <br /> 2. New wall sedions with dimensions should be shown on the draw�ngs and referenced <br /> from the plans. <br /> � 3. A lighling plan indicating the amount of relights should be shown on the plans. <br /> Alterations that replace 60% or more of the luminaires should be shown to comply with <br /> WSEC C101.4.3.1. <br /> Accessibility <br /> � 1. The new lavatory in the service room should be shown in elevation to be 34 inches <br /> maximum above the floor. <br /> Deferred Mechanical Permit <br /> � i. A separate mechanical permit with dra�vings to show ventilation to meet the <br /> requiremenks of IMC table 403.3. The following should be included: <br /> a. Catalog cuts of new equipment <br /> b. Equipment tables showir.g cfm and economize�s <br /> c. Structural review for new units over 400 pounds s��pported on the rooF. <br /> / 2. A roof plan should be submitted to locate exhaust and supply equipment. <br /> ✓ 3. The hood over the stove should be identified as a 7ype I, Type II or Hazardous Exhaust <br /> hood, per IMC sections 506 through 510. <br /> These comments address building issues only. Revisions or additions may be required by other <br /> departments (such as Utilities, Planning or Fire). All required submittals must be of sufficient <br /> detaii and information to ensure that the proposed structure will be constructed in compliance <br /> with all adopted codes. You can reach me directly to discuss this letter by e-mail at <br /> mhalev a everettwa.aov or by phone at 425-257-8813. <br /> Sincerely, <br /> eg ley, RA <br /> lan R iew Architect - <br /> � � <br />