My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1215 MADRONA AVE 2016-08-24
>
Address Records
>
MADRONA AVE
>
1215
>
1215 MADRONA AVE 2016-08-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2017 8:54:01 PM
Creation date
8/24/2016 9:44:35 AM
Metadata
Fields
Template:
Address Document
Street Name
MADRONA AVE
Street Number
1215
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br />' <br />' <br />' <br />� <br />' <br />' <br />� <br />' <br />' <br />' <br />' <br />1 <br />� <br />' <br />' <br />' <br />, <br />' <br />Gustafson Residence Retaining Wall NGA File No 924115 <br />1215 Madrona Avenue June 12, 2015 <br />Everett, Washington Page 9 <br />review final plans, observe test pile installation prior to finalizing design, monitor installation of the piles, <br />and evaluate pile refusal. <br />Tiebacks <br />General: If tieback anchors are needed for the wall design, we recommend that these systems could <br />include drilled, grouted tiebacks, or mechanically installed anchors such as helical anchors. We <br />recommend that one of the anchars be tested to a minimum of 200 percent of the design loads to confirin <br />desi�n values. We recoinmend that measurements be made by the contractar in the field at the time of <br />tieback installation to verify that tiebacks do not encounter any existing structures or underground <br />utilities. <br />No-Load Zone: The anchor portion of all tiebacks must be located a sufficient distance behind the wall <br />face to develop resistance within a stable soil mass. We recommend the anchorage be obtained behind an <br />assumed no-load zone. The no-load zone is defined by a line extending horizontally from the base of the <br />wall back towards the residence a distance of five feet. The line should then extend up from the base <br />elevation at an angle from the horizontal of 60 degrees. We expect that some undocumented fill may exist <br />beyond the no-load zone. We therefore recommend that the anchors be a minimum of 20 feet long. We <br />recommend that we monitor soil conditions during anchor installation in order to evaluate adequate <br />penetration into competent soils. <br />Soil Design Values: The tiebacks will likely terminate in glacial soils below the walls. For use in design <br />of the anchors, we estimate an allowable grout to soil adhesion of 1,000 pounds per square foot (ps�. <br />Load carrying capacities on the arder of 10 kips or more could be achieved using 8- to 10-inch diameter <br />helical anchors installed successfully. We recommend that we review anchor design and proposed <br />installation methods. We should also observe anchor installation and testing. <br />Tieback Installation and Testing: The contractor should be responsible for using equipment suited for <br />the site conditions. We do not recommend the use of open-hole methods for the purpose of installing the <br />tiebacks due to the potential for soil caving. Secondary grouting to increase soil adhesion may be used; <br />however, if secondary grouting is used, the anchors should be tested using the methods outlined for the <br />performance testing. <br />NELSON GEOTECHNICAL ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.