My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5106 S 3RD AVE 2016-09-13
>
Address Records
>
S 3RD AVE
>
5106
>
5106 S 3RD AVE 2016-09-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2017 11:19:06 PM
Creation date
8/31/2016 1:54:25 PM
Metadata
Fields
Template:
Address Document
Street Name
S 3RD AVE
Street Number
5106
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 16, 2011 <br />• <br />PUBL/C L�t/ORKS <br />Gabriel Liger <br />5106 South 3�d AVe <br />Everett WA 98203 <br />Subject: Project: <br />Job Address: <br />Plan Check No: <br />Dear Mr. Liger: <br />Liger <br />5106 South 3rd Ave <br />B1105-009 <br />� <br />In response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />(2009 International Building Code,) (2009 International Residential Code,) as amended by the <br />State of Washington and/or Washington State Energy Code 2009 Edition, and adopted by the <br />City of Everett, unless stated otherwise. <br />In order for the nrocessina of vour annlication to continue, it will be necessarv to <br />provide the Building Division with two new complete sets of drawings reflecting the <br />corrections requested. <br />1. Provide foundation ventilation calculation; show foundation vent locations on foundation <br />plan. <br />2. Provide minimum 2 anchor bolts per piece and within 12 inches of each end of each <br />piece; show requirement on plans. <br />3. Provide 6 mil black moisture barrier in crawl space, lap edges 12"; show on plans. <br />4. Provide section/detail for cripple walls where foundation does not attach directly to floor <br />assembly. <br />5. Specify connectors used at post/footing and post/beam. <br />6. Specify required insulation in existing floor joists per Washington State Energy Code, <br />2009 Edition. <br />7. Provide detail/section at front porch, rear structure at west end of house, and the <br />structure at the northwest corner of the existing structure. <br />V� <br />s/kcollison/heilman/B1105-009 (5106 So. 3r° Ave) <br />ENGINEERING / PUBLIC SERVICES DIVISION • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.