My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
320 74TH ST SW 2016-09-14
>
Address Records
>
74TH ST SW
>
320
>
320 74TH ST SW 2016-09-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2016 8:17:28 AM
Creation date
9/14/2016 8:17:19 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SW
Street Number
320
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
w w <br /> 2. Provide surveyors certificate for setbacks per the City of Everett zoning code. <br /> Required when addition is located within 12"of required setback. <br /> The surveyors certificate is required to be drawn to a legible scale, typically 1"=10' <br /> or 1"=20'. The document is also required to be signed by the surveyor. (2 copies <br /> required) <br /> 4. It appears that the Simpson MST 60 called out on the upper floor plan will not work <br /> in the configuration shown. Please detail the connection to show how loads are <br /> transferred at cantilever with sliding glass door under cantilever. <br /> The detail submitted is for a "hold down at beam/header", the condition on the plans <br /> is a cantilever please correct the detail. Verify with structural engineer that lateral <br /> loads are transferred to foundation at cantilever. <br /> 7. The general notes sheet should be updated to current codes. Simply changing <br /> reference to 2012 is not updating notes. <br /> The general notes on sheet 6 do not reflect current code requirements. For <br /> instance: <br /> — "WSEC prescriptive path (see table right); option IV" is from 2009 WSEC. <br /> — 'Sone rating 1.5"current requirement 1.0. <br /> — Ventilation notes are from WA State Ventilation and Indoor Air Quality Code. <br /> Current ventilation requirements are in section M1507 of the IRC. <br /> 9. Specify energy credit(s) per table 406.2 WSEC (0.5 credits required for addition of <br /> less than 750 square feet.) The building permit drawings shall identify which <br /> option(s) have been selected and the point value of each option. <br /> The option chosen requires that you specify a high efficiency whole house fan, size, <br /> location with a maximum 0.35 watts/CFM. Whole house fan shall be sized per table <br /> M1507.3.3 (1) IRC <br /> Also, 3 separate blower door tests will be required with the cumulative tested air <br /> leakage equal to 4.0 air changes per hour maximum. <br /> 10. Provide smoke alarms per R314 IRC show on plans. <br /> Smoke alarms not shown. <br /> 11. Provide carbon monoxide alarms per section R315 IRC show on plans. <br /> Carbon monoxide alarms not shown. <br /> 23 <br /> S:\1Common\Clerical\]Heilman\C1412-015(320 74th St SW)#2.doc / <br />
The URL can be used to link to this page
Your browser does not support the video tag.