Laserfiche WebLink
' � � <br />;' ���,,, <br />.; � " _r;,' <br />� �� �� �'r����%� <br />� H , � r'1'� <br /># ' � <br />` �� � � �' �i��l <br />� ��: , � <br />,:.. <br />� �°��;,;;;,�,_._ � � �` � t , � ; <br />a k, ' �i <br />� �; ; C <br />k a � + <br />��� ^ �'� . � � � � �. <br />E i�� . �� i,. � <br />( � f � �ai <br />y+C�,-"�,{�k t � 'a � ,������� <br />�'� °'ti r� , "� ' �� +i�� <br />� "" �. `' .. . .1A�,�- �%�,.� k .Y.'�t5�?�° <br />' . � �Y`" ' _ .. � ��..: _�"'�w.�w ....�. . �. i2"L <br />'� 2. Previous comment.• Existing or new emergency lighting should be shown on the <br />drawings, per IBC section 1006.1, where two exits are required, hardwired with battery <br />backup. Emergency lighting should be shown o�n the drawings on exterior landings, per <br />IBC section 1006.3(5). <br />� 3. Previous comment.• Since the occupant load of the daycare exceeds 49. existing or new <br />illuminated exit signs should be shown on the drawings, to include intervening means of <br />egress doors, and the path, where it is not immediately visible to the occupants, per IBC <br />section 1011.1. <br />,.�. Please identify on the drawings if the path of eqress includes the playground exterior <br />gates, which then should include illuminated exit signs, and emergency lighting. <br />�. Walking surfaces of the means of egress should be shown on the drawings to have a <br />slip-resistant surface and be securely attached, per IBC section 1003.4. <br />Construction <br />✓1. Previous comment.� The apartment shown on permit 13819 in 1984 has been <br />subsequently removed. The demo work to remove this apartment should be shown on <br />the drawings as part of the scope of work for t�ris permit. <br />�.; Please provide elevations and details of the toilet room partitions on the drawings, to <br />`_ _' include doors on two of the three toilets in each toilet room, per IBC section 1210.3.1, <br />exception 2. <br />� <br />3. The kitchen has an existing pass through partition on the west wall. Please include that <br />information on the plans, and indicate the height in an elevation. <br />, 4. A menu for the proposed daycare, or a letter from the property manager, should be <br />`� submitted to indicate that the cooking equipment in the kitchen will not be used for <br />roasting, pan-frying, or deep-frying, which would require a Type I hood per IMC section <br />507.2.2. <br />5. Please clarify hardware revisions with a door schedule for clarity, referencing door <br />U`���� numbers on the drawings. <br />� <br />