My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 SE EVERETT MALL WAY BUFFALO WILD WINGS 2016-09-20
>
Address Records
>
SE EVERETT MALL WAY
>
1402
>
BUFFALO WILD WINGS
>
1402 SE EVERETT MALL WAY BUFFALO WILD WINGS 2016-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 12:50:23 AM
Creation date
9/20/2016 2:56:49 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1402
Tenant Name
BUFFALO WILD WINGS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ � � • • <br />2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 <br />Project Address Everett Mall Date 3/3/2015 <br />The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br />WSEC. NOTE: Define rint area in Excel rior to rintin MECH-CHK a es. <br />Applicability Location on Building Department <br />(yes,no,na) Code Section Code Provision Information Required Plans Notes <br />GENERAL PROVISIONS, CONTINUED <br />HVAC System Controls 8 Criteria, Continued <br />NA C403.2.12 Variable flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv <br />fans/ um s controls <br />NA C4032.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method <br />coolin towers <br />NA C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and <br />coolin demand; or exce tion taken <br />C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for sys. > 110,000 <br />YES bt"n M 102 <br />NA C4032.4.10 DDC system capabilities Identify all DDC system inpuVoutput control points and indicate capability <br />Ducting Systems <br />C4032.7.1 & Indicate all ductwork constructed and sealed per IMC, C402 leakage <br />YE$ C403.2.7.3 Duct construction re uirements and IBC va or retarder re uirements SPEC <br />YE$ 4032.7.3.1- Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M 100 <br />C4032.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide <br />NA test test results to 'urisdiction when com leted <br />YE$ C403.2.7.1 / Duct insulation Indicate R-value of insulation on ductwork SPEC <br />Piping Systems <br />NA C403.2.8 Piping insulation Indicate R-value of insulation on piping <br />NA C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage/degredation <br />weather <br />51MPLE SYSTEMS <br />Qualifying Systems <br />C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, does <br />YE$ s stems not have active humidifcation or simultaneous heatin /coolin M 102 <br />NA C403.3 Qualifying 2-pipe heating Verify 2-pipe heating-only system does not exceed capacity limits <br />s stems <br />NA C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 <br />Simple System Economizers <br />YES C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip M 102 <br />sched. <br />YE$ C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M 102 <br />YE$ C403.3.�.1.3 Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 102 <br />controls <br />YE$ C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with M 102 <br />o eration ca aci > 65 000 btuh <br />NA C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with <br />COMPLEX SYSTEMS <br />Complex System Economizers <br />C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip <br />NA sched. <br />C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not <br />NA impact increase building heating energy usage during normal operation <br />NA C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo <br />o eration s stems <br />Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb <br />NA os,a <br />C403.4.1.2 Water economizer maximum Indicate precooling coils and heat exchangers do not exceed pressure drop <br />NA pressure drop limit <br />NA C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with <br />
The URL can be used to link to this page
Your browser does not support the video tag.