My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 SE EVERETT MALL WAY BUFFALO WILD WINGS 2016-09-20
>
Address Records
>
SE EVERETT MALL WAY
>
1402
>
BUFFALO WILD WINGS
>
1402 SE EVERETT MALL WAY BUFFALO WILD WINGS 2016-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 12:50:23 AM
Creation date
9/20/2016 2:56:49 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1402
Tenant Name
BUFFALO WILD WINGS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ ■ � � • <br />2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 <br />ProjectAddress EverettMall Date 3/3/2015 <br />The following information is necessary to check a mechanical pertnit application for commercial provision compliance with the 2012 <br />WSEC. NOTE: Define rintarea in Excel riorto rintin MECH-CHK a es. <br />Applicability Location on Building Department <br />(yes,no,na) Code Section Code Provision Information Required Plans Notes <br />COMPLEX SYSTEMS, CONTINUED <br />Specific System Requirements <br />C403.4.2 & Variable flow control - fans Indicate fans requiring variable flow control and method <br />C403.2.12 <br />C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans; include at least one sensor per major <br />sensors ductbranch <br />C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most <br />set oint ressure <br />VAV systems serving multi- �ndicate supply air systems serving multiple zones that are required to be <br />C403.4.5 VAV, method of primary air control, and zones served; note exceptions <br />zones <br />taken <br />C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to <br />loads <br />C403.4 Large capacity cooling Indicate method of multi-stage or variable control for building cooling <br />s stems s stem ca aci > 300 tons <br />C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method <br />C403.4.3 Large capacity boiler Indicate multi-stage or modulating bumer for single boilers > 500,000 btuh <br />s stems <br />C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers <br />C403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off <br />isolation flow through chillers & boilers when not in use <br />C403.4.2 8 Variable flow control - �ndicate pumps requiring variable flow control & method <br />C403.4.3.6 pumps <br />C4032.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method <br />& C403.4.4 coolin towers <br />C403.4.3.4 Hydronic system part load reset supply water temp AND reduce flow by z 50% for systems > 300,000 <br />controls <br />C403.4.3.2 Two-pipe changeover Indicate deadband, heating/cooling mode scheduling and changeover <br />s stems tem erature ran e <br />C403.4.3.3.1 Water loop heat pump - Indicate capability of central equipment to provide min. 20°F water suppiy <br />deadband tem deadband between heat re'ection and heat addition modes <br />C403.4.3.3 Water loop heat pump - Provide heat exchanger that separates cooling tower and heat pump loop in <br />heat re'ection Climate Zone 5 <br />Water loop heat pump - Indicate 2-way isolation valve on each heat pump and variable flow control <br />C403.4.3.3.3 isolation for s stems with total um ower > 10 h <br />C403.4.6 Condenser water heat Indicate system provided to pre-heat service water and effciency <br />recovery <br />C403.5 Cooler / freezer - anti-sweat Indicate w/sf & control method for walk-in coolerlfreezer door anti-sweat <br />heaters heaters <br />C403.5 / 6 Cooler / freezer - evaporator Indicate motor type for evaporator and condenser fans < 1 hp <br />SERVICE WATER HEATING <br />Service Water Systems <br />�� 2 Water-heating equip min. Provide equipment schedule or complete MECH-SUM table with type, <br />efficienc ca aci efficienc test standard or other efficienc source <br />C404.3 Temperature controls Indicate temperature controls have required setpoint capability <br />C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & <br />dischar e <br />C404.5 �nsulation under water Indicate R-10 insulation under tank <br />heater <br />C404.6 Service water piping Indicate R-value of insulation on piping; note exceptions taken <br />insulation <br />C404.7 ! 8 Circulation systems and Indicate shut-off capability based on occupancy and periods of limited <br />heat trace shut-off demand <br />C404.9 Group R-2 service hot water Indicate method of usage metering for dwell. units served by central HW <br />Pools & In-Ground Pertnanently Installed Spas <br />Pool heating equip min. Provide equipment schedule or complete MECH-SUM table with type, <br />C404.10.1 efficiency �Pacity, efficiency, test standard (or other eff. source); heat pump heaters <br />2 4 COP <br />C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling 8 accessible onloff <br />switch on heater that o erates inde endent of thermostat settin � or <br />C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required <br />C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F <br />C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy <br />
The URL can be used to link to this page
Your browser does not support the video tag.