Laserfiche WebLink
� � • � ' � • • <br />2012 Washington State Energy Code Compliance rorms for Commercial Buildings including R2 & R3 over 3 stories and all R1 <br />ProjectAddress Everett Mall Date 3/3/2015 <br />The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy <br />Code, Commercial Provisions. <br />Applicability Code Location in Building <br />(yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br />SCOPE <br />C101.52 Low energy spaces Low energy spaces identified on plans <br />C101.5.21 Semi-heated spaces Semi-heated spaces identified on plans �4 �� ^�Sf�/,ti� <br />C402.1.4 <br />C402.5 Cooler and freezer Walk-in and refrigerated warehouse cooler and freezer spaces iden '' ! � <br />C402.6 spaces plans <br />C101.4.6 Mixed occupancy Spaces with different occupancy requirements identified on plan '� <br />C101.4.4 Change of Existing F, S and U-occupancy building spaces undergoing a cha e <br />C101.4.5 occupancy/space occupancy or space conditioning that require compliance are identi ied on � 0036789 <br />conditioning plans �/ , �'C' l��'� � <br />ENVELOPE PROVISIONS �'5����n'�� �-� <br />C303.1 Insulation Indicate identification mark shall be applied to all insulation materials <br />identification <br />C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor, SHGC, VT, and <br />C402.4.3 rating leakage rating <br />Indicate installation methods, thicknesses, densities and clearances to <br />C303.1.1 General insulation achieve the intended R-value of all insulation materials; <br />C402.2 installation Where two or more layers of rigid insulation will be used, indicate that edge <br />joints between layers are staggered <br />Indicate R-value(s) of cavity/continuous insulation on roof sections; <br />Indicate framing materials on roof sections; <br />Indicate method of framing for ceilings below vented attics and vaulted <br />C402.2.1 Roof assembly ceilings per A102.2 (std, adv); <br />insulation provide area-weighted calculations for sloped insulation installed entirely <br />above deck; <br />Indicate R-values for thermal spacers and each insulation layer, and liner <br />system (LS) method for metal building roofs <br />C4022.1 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight <br />insulation NFRC rating <br />Indicate R-value(s) of cavity/continuous insulation on wall sections; <br />Indicate framing materials on wall sections; <br />C4022.3 Indicate method of framing for wood const per A103.2 (std, int, adv); _ <br />C402.2.4 Above/below grade Indicate mass of masonry walls; <br />C303.2.1 Wall insulation <br />Indicate loose-fill core insulation material, percentage of cores filled, and <br />frequency of grouted cores and bond beams for masonry walls; <br />Indicate method of protection of exposed exterior basemenUcrawlspace wall <br />insulation <br />Walk-in/refrigerated Indicate insulation R-values of ceilings, walls, doors, floors on sections; <br />C402.5 warehouse cooler - <br />C402.6 and freezer Indicate method of minimizing door infiltration; _ _ <br />insulation Indicate type(s) of transparent doors and windows <br />C4022.7 Opaque doors Indicate rated U-factor (swinging) or R-value (roll-up/sliding) on wall sections - <br />applies to doors with less than 50 /o glazed area <br />Floor over outdoor or Indicate R-value(s) of cavity/continuous insulation on floor sections; <br />C402.2.5 unconditioned space Indicate framing material on floor sections; <br />insulation Indicate mass of masonry floors <br />Indicate R-value of continuous insulation on wall section or foundation detail; <br />C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically andlor horizontally the required <br />C303.2.1 insulation distance from top of slab; <br />Indicate method of protection of exposed exterior slab edge insulation <br />Indicate R-value of continuous insulation on wall section or foundation detail; <br />C402.2.6 Radiantly heated Indicate insulation extends down vertically from top of slab and then <br />C303.2.1 slab-on-grade floor horizontally under the entire slab; <br />insulation – --- - — <br />Indicate method of protection of exposed exterior slab edge insulation <br />Radiant heating Indicate insulation R-value behind radiant panels, U-bend/headers and <br />C402.2.8 system insulation bottom surtace of radiantly heated floors (other than radiantly heated slab-on- <br />grade) <br />