ELECTRICAL NOTES ELECTRICAL NOTES (CON'T) EXISTING: Sprint <br /> 1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL 15. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC <br /> ELECTRICAL CODES AND ALL LOCAL AND STATE CODE. LAWS.AND ORDINANCES. PROVIDE TABLE 346-10. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT SITE NUMBER: SE63C209 MODEL NUMBER: LINK <br /> VOLTAGE: 240V 120 PHASE: 1 WIRE: TBD <br /> ALL COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC STANDARDS. ELBOWS WITH 12'MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2`OR LARGER. MAIN BREAKER: 100 AMP BUSS RATING: 100 AMPS A/C: TBD <br /> 2. CONTRACTOR SHALL COORDINATE WITH LOCAL POWER COMPANY FOR REQUIREMENTS OF 16, ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT MOUNT: SURFACE NEUTRAL BAR: TBD GROUND BAR: TBD <br /> ENCLOSURE TYPE: TBD N to GROUND BOND: TBD <br /> POWER SERVICE LINE TO THE METER BASE, WHEN REQUIRED. POWER SERVICE INSULATING GROUNDING BUSHINGS. PANEL STATUS: EXISTING INTERNAL NSS: TBD <br /> REQUIREMENT IS COMMERCIAL.AC NOMINAL 120/208 VOLT OR 120/240 VOLT, SINGLE BREAK E___ET BREAKER BREAKER BREAKER M/A <br /> PHASE WITH 200 AMP RATING. 17. ALL WIRE SHALL BE -TYPE THWN, SOLD. ANNEALED COPPER UP TO SIZE 1/10 CKT LOAD DESCRIPTION <br /> AMPS I POLES STATUS RTATU� DESCRIPTION LU <br /> AWG(18 AND LARGER SHALL BE CONCENTRIC STRANDED) 75 DEGREE C, (167 1 BTS EQUIPMENT 100 2 -- FI 2 <br /> 3. CONTRACTOR SHALL COORDINATE WITH LOCAL TELEPHONE COMPANY FOR SERVICE LINE DEGREES F),98' CONDUCTIVITY. MINIMUM #12. _ __ __ <br /> REQUIREMENTS TO TERMINATE AT THE PPC CABINET. 3 - 2 PRINT 4 <br /> 4. CONTRACTOR SHALL FURNISH AND INSTALL ELECTRIC METER BASE AND 200A 18. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES. J-BOXES, EQUIPMENT 5 BLANK -- -- N/A ON -- - 6 GENERAL DYNAMICS <br /> DISCONNECT SWITCH PER SITE PLAN DETAIL DRAWINGS AND PER LOCAL UTILITY BOXES AND CABINETS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY. OR 7 BLANK -- -- N/A N A N A LANK B <br /> COMPANIES SPECIFICATION, WHEN REQUIRED.THE METER BASE SHOULD BE LOCATED IN APPROVED EQUAL 9 BLANK -- -- N A N A N A LANK f0 WIRELESS SERVICES <br /> A MANNER ACCESSIBLE BY THE LOCAL POWER COMPANY. 19. ALL NEW MATERIAL SHALL HAVE A U.L LBEL 11 BLANK -- -- N A N A N A LANK 1273 BUNK N A N A N A LANK 14 <br /> 5. LOCAL POWER COMPANY SHALL PROVIDE 200 AMP ELECTRIC METER. CONTRACTOR SHALL 2D. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT 15 BLANK N/A N/A N/A N/A LANK 16 <br /> COORDINATE INSTALLATION OF METER WITH LOCAL POWER COMPANY. TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND <br /> 6. UNDERGROUND POWER AND TELCO SERVICE UNES SHALL BE ROUTED IN A COMMON COMPLY AS REQUIRED. <br /> TRENCH.ALL UNDERGROUND CONDUIT SHALL BE PJC SCHEDULE 40 AND CONDUIT 21. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN. <br /> EXPOSED ABOVE GROUND SHALL BE GALVANIZED RIGID STEEL TUBING UNLESS ENGINEERING <br /> OTHERWISE INDICATED. 22. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE <br /> SPECIFICATIONS AND NEC.THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE PROJECT INFORMATION: <br /> 7. ALL TELCO CONDUIT LINES SHALL BE 4'SCH. 40 PVC CONDUIT UNLESS OTHERWISE BONDED AT ALL JUNCTION BOXES. PULLBOXES,AND ALL DISCONNECT SWITCHES, <br /> INDICATED. THE TELCO CONDUIT FROM THE PPC SHALL BE ROUTED AND TERMINATED AT STARTERS,AND EQUIPMENT CABINETS. NCTWc.RK VISION MMBS LAUNCH <br /> DESIGNATED TELCO DEMARCATION OR 2-FEET OUTSIDE FENCED AREA, NEAR UTILITY l l <br /> POLE (IN FENCED AREA), OR END CAP OFF AND PROVIDE MARKER STAKE PAINTED 23. THE CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS. DOCUMENT ANY AND NEW: <br /> BRIGHT ORANGE WITH DESIGNATION FOR TELCO SERVICE. ALL WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS <br /> CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. SITE NUMBER: SE63C209 MODEL NUMBER: TBD BROADWAY <br /> 8. CONDUITS INSTALLED AT PCS EQUIPMENT ENDS PRIOR TO THE EQUIPMENT VOLTAGE: 240V/120 PHASE: 1 WIRE: TBD <br /> INSTALLATION SHALL BE STUBBED AND CAPPED AT 6"ABOVE GRADE OR PLATFORM. IF 24. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE MAIN BREAKER: 200 AMP BUSS RATING: 200 AMPS A/C: TBD <br /> SERVICE LINES CAN'T BE INSTALLED INITIALLY. PROVIDE NYLON PULL CORD IN CONDUITS. PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES INDICATING EQUIPMENT MOUNT: SURFACE NEUTRAL BAR: TBD GROUND BAR: TBD <br /> CONTROLLED, BRANCH CIRCUITS INSTALLED ON.AND PANEL FIELD LOCATIONS ENCLOSURE TYPE: TBD N to GROUND BOND: TBD SE63XC209 <br /> 9. THE SPRINT CABINET, INCLUDING 200 AMP LOAD PANEL AND TELCO PANEL.SHALL BE FED FROM (NO EXCEPTIONS.) PROVIDE SAMPLE FOR CONSTRUCTION MANAGER'S PANEL STATUS: EXISTING INTERNAL NSS: TBD <br /> PROVIDED BY OWNER AND INSTALLED BY THE CONTRACTOR CONTRACTOR IS TO INSTALL APPROVAL BREAKER BREAKER BREAKER BREAKER BREAKER BREAKER2$17 HOWARD AVE <br /> BREAKER(S) NOT PROVIDED BY MANUFACTURER. SEE PANEL SCHEDULE ON THIS SHEET CKT LOAD DESCRIPTION <br /> FOR BREAKER REQUIREMENTS. 25. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY 1 SAMSUNG MMBS CABINET 100 2 NEW NEW 2 125 EXISTING 100A PANEL 2 EVERETT, WA 98203 <br /> WITH (ADA) AMERICANS WITH DISABILITIES ACT AS ADOPTED BY THE APPUCABLE 3 <br /> 10. LOCATION OF ELECTRIC METER AND DISCONNECT SWITCH TO BE PROVIDED BY GENERAL STATE. <br /> CONTRACTOR. 5 SAMSUNG BBU CABINET 15 2 NEW N/A N/A N/A BLANK 6 SNOHOMISH COUNTY <br /> 26. PROVIDE CORE DRILUNG AS NECESSARY FOR PENETRATIONS OR RISERS 7 -- -- -- -- N/A N/A N/A BLANK B <br /> 11. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY THROUGH BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT 9 BLANK N/A N/A N/A N LA BLANK 10 <br /> QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONSTRUCTION MANAGERS APPROVAL SLEEVES ANO/OR PENETRATIONS IN FIRE 11 BLANK -- -- N/A N 7A7 N A N A BLANK 12 ISSUE DATE <br /> CONTRACTORS FUNCTIONS.THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO RATED CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH 07-30-12 <br /> THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FILL FOR <br /> PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND <br /> 12. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. ISSUED FOR-* ZONING/PERMITTING <br /> APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO 27. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT(NEW AND EXISTING)SHALL BE <br /> ROUGH-IN. FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLER <br /> 13. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION PRIOR TO ROUGH-IN Of CONDUIT AND WIRE.ALL EQUIPMENT SHALL BE REVISIONS <br /> PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON REV. DATE DESCRIPTION INITIALS <br /> AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED UPON BEST <br /> 14. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC. AVAILABLE INFORMA11ON AT THE TIME OF DESIGN AND SOME EQUIPMENT A 07/30/12 90%CO'S J.F_ <br /> CHARACTERISTICS MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). <br /> 28. LOCATION OF ALL OUTLET, BO%ES, ETC., AND THE TYPE OF CONNECTION (PLUG 0 09/12/12 100%CO'S RLS <br /> OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR <br /> TO ROUGH-IN. <br /> NOTES <br /> ELECTRICAL CONTRACTOR SHALL BE RESPONSELE M OBTAIN ELECTRICAL PEIW IF REQUIRED AND <br /> ENSURE FRAL INSPECTION OF INSTALLATION IS ACCEPTABLE TO THE AUTHORITY HAVING JURTSOICTION <br /> OVER THE WORK UNDERTAKEN. <br /> 22"x34'SCALE NOT TO SCALE <br /> 11'z17'SCALE NOT TO SCALE ELECTRICAL NOTES 1 ELECTRICAL PANEL SCHEDULE 2, <br /> EXISTING 200A METER <br /> 1 2 EXISTING INCOMING POWER <br /> SOURCE TO BE DISCONNECTED <br /> TO EXISTING UTILITY POWER N, UPON INSTALLATION OF NEW <br /> SOURCE 200A SERVICE <br /> LOAD CENTER AND MAIN NOT FOR CONSTRUCTION UNLESS <br /> DISCONNECT LABELED AS CONSTRUCTION SET <br /> 100A <br /> EXISTING 20DA METER J LICENSURE <br /> 6 <br /> J <br /> TO EXISTING UTIL11Y POWER M EXISTING SERVICE GROUND <br /> SOURCE <br /> NEW LOAD CENTER AND MAIN <br /> DISCONNECT ° <br /> 200ANEW NEW BBU <br /> NEW SERVICE GROUND MMBS C BINET EXISTING LOADS (REFER TO <br /> CABINET PANEL SCHEDULE n <br /> CIRCUIT SCHEDULE 125A <br /> n n <br /> ]NO FROM 70 CONFIGURATIONn /�100A SOURCE METER CENTER EXISTING15ASWITCH <br /> METER/DSC TRALOADRCENTER EXISTING /-� SHEET TITLE <br /> TRANSFER& LOAD NEW MMBS CABINET (3) #2 AWG, (1) #8 GND IN NEW LOADS (REFER TO PANEL /\ /1 NEW LOADS (REFER TO PANEL <br /> CENTER SUB-PANEL 2" CONDUIT SCHEDULE SCHEDULE ONE-LINE DIAGRAM & <br /> TRANSFER & LOAD NEW BBU CABINET (3) $10 AWG, (1) GND IN <br /> t3 POWER PANEL SCHEDULE <br /> ® CENTER SUB-PANEL "CONDUIT <br /> n � <br /> © 'SOURCE METER CENTER (3)f3/0 THHN, (1)#6 GND IN <br /> 2"CONDUIT a <br /> METER/DSC NUMBER REVISION: <br /> n n <br /> TRANSFER SWITCH& (3)/'3/O" CN, *6 GND IN �\ <br /> © LOAD CENTER 2" CONDUIT 0 <br /> TRANSFER SWITCH & TRANSFER SWITCH& (3)/1 THHN, (1) M6 OND IN <br /> ® LOAD CENTER LOAD CENTER 1 1/4"CONDUIT <br /> E-1 <br /> 22"x34'SCALE: NOT TO SCALE <br /> 11'x17'SCALE NOT TO SCALE ELECTRICAL ONE-LINE DIAGRAM 3 1257080 <br /> THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. i <br />