My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3305 NASSAU ST WA CENTER FOR PAIN MANAGEMENT 2016-10-04
>
Address Records
>
NASSAU ST
>
3305
>
WA CENTER FOR PAIN MANAGEMENT
>
3305 NASSAU ST WA CENTER FOR PAIN MANAGEMENT 2016-10-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 1:32:01 AM
Creation date
10/4/2016 8:13:05 AM
Metadata
Fields
Template:
Address Document
Street Name
NASSAU ST
Street Number
3305
Tenant Name
WA CENTER FOR PAIN MANAGEMENT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 <br />Project Address 3305 Nassau St. Date 2/12/2014 <br />The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br />WSEC. NOTE: Define rint area in Excel rior to rintin MECH-CHK a es. <br />Applicability Location on Building Department <br />(yes,no,na) <br />Code Section Code Provision Information Required Plans Notes <br />GENERAL PROVISIONS <br />Equipment Sizing & Performance <br />C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per M 1 <br />Y2S Cha ter 3 <br />C403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not M 1 <br />YeS sizin exceed calculated loads note exce tions taken <br />Ventilation (natural or mechanical) provided per IMC; indicate mechanical M 1 <br />Ye5 C4032.5 Minimum ventilation ventilation is ca able of bein reduced to minimum re uirement er IMC <br />C403.2.3 & Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, <br />C403.2.3.2 & capacity, efficiency, test standard (or other efficiency source) for all <br />Ye5 C4032.12.1 efficiency mechanical equipment M1 <br />N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note <br />exce t. <br />C403.2.10 Fein power limitation Fan system motor hp or bhp does not exceed limits per Table <br />N/A C4032.10.1 1 <br />C403.2.10.3 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency <br />N/A & C403.2.13 re . <br />C403.2.3 Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit <br />N/A ca acit <br />C403.2.1 Non-standard water-cooled Full-load and NPLV values for water-cooled centrifugal chiller adjusted for <br />N/A chillers non-standard o erational conditions <br />C403.2.12.1. Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency <br />N/A towers requirements for axial fan open circuit cooling towers <br />N A C403.2.3 heatetl air furnace and unit Indicate intermittent ignition or IID, flue/draft damper & jacket loss <br />� <br />C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule <br />N/A heatin /coolin e ui ment <br />N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with <br />economizer <br />HVAC System Controls & Criteria <br />C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including M1 <br />Ye5 erimeter s stems <br />C403.2.4.1.� Heat pump supplementary Indicate staged heating (compression/supplemental) & outdoor lock-out M1 <br />Ye5 heat tem <br />C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & M1 <br />YE'S coolin <br />C403.2.4.3 Automatic setback and Indicate zone t-stat controls with required automatic setback 8 manual M1 <br />Ye5 shutdown override <br />C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load M 1 <br />Y25 conditions <br />C402.4.52 & Indicate location of OSA, exhaust, relief and return air dampers; include <br />Yes Dampers M1 <br />C403.2.4.4 AMCA rated leaka e and control t e motorized or ravit note exce tions <br />YeS C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls M� <br />N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions <br />N/A C403.2.4.6 Combustion heating Indicate modulating or staged control <br />e ui ment <br />N/A C403.2.4.7 Group R1 hotel/motel Indicate method for guest room automatic setback & set-up of 5°F <br />s stems minimum <br />N/A C4032.4.8 / Group R2/R3 dwelling unit Indicate 5-2 programmable thermostats in primary spaces with minimum of <br />s stems two setback eriods note exce tions taken <br />C4032.5.1 Demand controlled Indicate high-occupancy spaces and systems requiring DCV M 1 <br />YeS ventilation <br />C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy-based system control and method; or M1 <br />Ye5 alternate means rovided to automaticall reduce OSA when artiall <br />Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation <br />C4032.5.3 dock/parking garage <br />Ye5 ventilation system activation and control method M 1 <br />N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source <br />and conditionin method <br />Indicate lab exhaust systems requiring heat recovery, method & efficiency; <br />N/A C403.2.5.42 Laboratory exhaust systems or alternative method taken (VAV, semi-conditioned makeup, or CERM <br />calculation <br />C4032.6.1 Energy recovery - Indicate ventilation systems requiring ER, method R efficiency; note <br />N/A ventilation systems exceptions <br />N/A C403.2.6.2 Energy recovery - Indicate on-site steam heating systems requiring energy recovery <br />condensate s stems <br />N/A C403.2.6.3 Energy recovery - Indicate remote refrig. condensers requiring ER and use of captured energy <br />condenser s stems <br />
The URL can be used to link to this page
Your browser does not support the video tag.