My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3305 NASSAU ST WA CENTER FOR PAIN MANAGEMENT 2016-10-04
>
Address Records
>
NASSAU ST
>
3305
>
WA CENTER FOR PAIN MANAGEMENT
>
3305 NASSAU ST WA CENTER FOR PAIN MANAGEMENT 2016-10-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 1:32:01 AM
Creation date
10/4/2016 8:13:05 AM
Metadata
Fields
Template:
Address Document
Street Name
NASSAU ST
Street Number
3305
Tenant Name
WA CENTER FOR PAIN MANAGEMENT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br />._ . . • � <br />2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised ,lune 20�3 <br />Project Address 3305 Nassau St. Date 2/12/2014 <br />The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br />WSEC. NOTE: Define rint area in Excel rior to rintin MECH-CHK a es. <br />Applicability Code Section Code Provision Information Required Location 8uilding Department <br />(yes,no,na) on Plans Notes <br />GENERAL PROVISIONS, CONTINUED <br />HVAC System Controls & Criteria, Continued <br />C403.2.12 Variable flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv <br />N/A fans/ um s controls <br />C4032.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method <br />N/A coolinc towers <br />C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and <br />N/A coolin demand; or exce tion taken <br />C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for sys. > 110,000 <br />N/A btuh <br />N A C403.2.4.10 DDC system capabilities Identify all DDC system inpuUoutput control points and indicate capability <br />� frrnin m m� r n im m� <br />Ducting Systems <br />C4032.7.1 & Indicate all ductwork constructed and sealed per IMC, C402 leakage M 1 <br />YeS C403.2.7.3 Duct construction re uirements and IBC va or retarder re uirements <br />403.2.7.3.1- Duct pressure Identify location of low, medium and high pressure ductwork on plans <br />N/A classifications <br />C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide <br />N�A test test results to "urisdiction when com leted <br />Ye5 C403.2.7.1 / Duct insulation Indicate R-value of insulation on ductwork M1 <br />Piping Systems <br />N/A C403.2.8 Piping insulation Indicate R-value of insulation on piping <br />N/A C4032.8.1 Piping insulation exposed to Indicate method of protection from damage/degredation <br />weather <br />SIMPLE SYSTEMS <br />Qualifying Systems <br />C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, M1 <br />Ye5 s stems does not have active humidifcation or simultaneous heatin /coolin <br />N/A C403.3 Qualifying 2-pipe heating Verify 2-pipe heating-only system does not exceed capacity limits <br />s stems <br />N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 <br />Simple System Economizers <br />Indicate cooling systems requiring economizer controls; note in equip <br />YeS C403.3.1 Air economizer required sched. M 1 <br />Ye5 C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100 % OSA, or exception M 1 <br />C403.3.1.1.3 Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 1 <br />Ye5 controls <br />C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with M 1 <br />Y25 o eration ca aci > 65 000 btuh <br />Indicate eligible exception(s) taken and provisions to comply with <br />Ye5 C403.3.1 Air economizer exceptions M 1 <br />xce i n <br />COMPLEX SYSTEMS <br />Complex System Economizers <br />C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip M 1 <br />Yes sched. <br />C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not <br />Y2S impact increase building heating energy usage during normal operation M 1 <br />C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo M 1 <br />Y25 o eration s stems <br />Moved Water economizer capacity Indicate water econo capable of 100 % cooling capacity at 50°F db/45°F wb <br />N/A osa, <br />C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure <br />N/A maximum pressure drop drop limit <br />N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with <br />x in <br />
The URL can be used to link to this page
Your browser does not support the video tag.