Laserfiche WebLink
� <br />( Botesch, Nasb 8F Hall <br />Archi#ects, P.S. <br />April 16, 2013 <br />ATTN: Jeff Heilman <br />City of Everett <br />RE: Carson House <br />1526 Oakes Avenue <br />Plan Check No: C1303-010 <br />Architectural Comments: <br />� <br />1. Provide section and/or details for exterior "skirting" capable of resisting wind <br />and seismic loading. <br />Sheet AF1.0 — Added detail 2/AF1.0 showing typical skirting condition. <br />Sheet AF1.0 — ADD KEYNOTE 1.9: "1/4" FIBER CEMENTITIOUS SKIRTING. <br />FASTEN PER MANUFACTURER'S REQUIREMENTS. PROVIDE BLOCKING <br />AT EACH FOUNDATION VENT OPENING. <br />2. Specify all window sizes, designate as existing or new. Show all windows in <br />proposed configuration? <br />Sheet A1.0 — All window sizes have been noted on plans. All windows are <br />new. <br />3. Provide all header sizes, species and grade of lumber, and location on plans. <br />Sheet A1.0 — ADD GENERAL NOTE #3: "ALL WINDOW HEADERS TO BE <br />4x8 DOUGLAS FIR #2 UNLESS NOTED OTHERWISE". <br />4. Note on drawing "50% of all luminaries shall be high efficiency luminaries" per <br />WA state Energy Code (WSEC). <br />Sheets A1.0 — ADD GENERAL NOTE: "ELECTRICAL — 50% OF ALL <br />LUMINARIES SHALL BE HIGH EFFICIENCY LUMINARIES" <br />5. Provide minimum 50 CFM exhaust fans, vented outside, in "bathroom 104". <br />; ._ <br />