Laserfiche WebLink
• <br />� <br />Sheet A1.0 — Added 50CFM exhaust fan and keynote 1.5 to bathroom 104. <br />6. Show water heater location on plans. Specify seismic straps and pressure <br />relief valve. <br />Sheet A1.0 — ADD KEYNOTE 1.8: "ELECTRIC WATER HEATER WITH <br />PRESSURE RELIEF VALVE. PROVIDE SEISMIC STRAPS IN THE UPPER <br />ONE-THIRD AND IN THE LOWER ONE-THIRD OF THE APPLIANCE TO <br />RESIST A HORIZONTAL FORCE EQUAL TO ONE-THIRD OF THE <br />OPERATING WEIGHT OF THE WATER." <br />7. How is structure heated? Show furnace location on p�ans. <br />Sheet AF1.0 — Gas fired furnace shown on foundation plan. <br />8. Note on plans "whole house fan to be continuously operated" or provide <br />calculation for intermittent fan per M1508.3 IRC. <br />Sheet G1.0 — Added whole house ventilation calculation per IRC M1508.3 <br />9. Specify on plans how fresh air is provided for compliance with section M1508 <br />I RC. <br />� <br />Sheet AF1.0 — ADD KEYNOTE 1.�: "GAS FORCED AIR FURNACE. <br />CONTRACTOR TO VERIFY THAT A MINIMUM OUTSIDE AIR FLOW RATE OF <br />113CFM IS PROVIDED IN ACCORDANCE WITH WHOLE HOUSE <br />VENTILATION CALCULATION ON SHEET G1.0." <br />10. Provide handrail per R311.7.7 IRC. Show requirement on plans. Show <br />location of handrail on plans. <br />Sheet A1.0 — Detail 7/A1.0 modified to show handrail. <br />Sheet A1.0 — ADD KEYNOTE 1.11: "HANDRAIL. SEE DETAIL 7/A1.0." <br />11. Detail 2 on sheet A1.0 Typ. Ceiling detail, shows 2x6 joists spliced to 2x4 <br />studs. Show in plans where this condition is proposed. If the intent is to <br />increase the span of the ceiling joists, show bearing for new ceiling joists. <br />Provide gravity calc's for the new ceiling joists. <br />Sheet A1.0 — Delete detail 2/A1.0. <br />ADD SHEET AF1.1 — New roof system to be pre-engineered wood truss at <br />24" o.c. <br />