� • . <br />6. Foundation vents are required within 3'-0" of all corners the plans show vents located <br />3'-0" from the corner. <br />7. Deck and stair detail shows footings for landing and stairs above grade. Footings shall <br />rest on undisturbed soil not less than 12" below the finished grade. <br />8. Note on plans "1 �/4"-2" diameter handrails. 34" min., 38" max. above tread nosing. <br />Return ends." � <br />9. Specify lag screws at ledger shall be staggered top & bottom. <br />10. Specify roof truss connection(s) at double top plate capable of transferring roof <br />diaphragm loads into walls and resisting uplift. <br />11. Provide gravity calculation for 4 x.12 D.F. #2 @ fireplace supporting point load of girder <br />truss. <br />12. Specify roof overhang on framing plan, eave detail and elevations. (see #14 below) <br />13. Note on plans'�110 volt smoke alarms with battery back-up and interconnected." <br />14. Provide elevation drawings for all four sides. Show window sill height above finished <br />floor, roof pitch, roof overhang, siding, fireplace cantilever and exterior porches & stairs. <br />15. Provide minimum 22" x 30" attic access located in a hallway or other readily accessible <br />location. Minimum unobstructed headroom in the attic space shall be 30 inches. Show <br />on plans. <br />16. Insulation of ducts shall comply with the requirements of table 5-11 WA State Energy <br />Code. <br />Please prepare a response letter showing where each item in this correction letter is <br />addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />that the proposed structure will be constr,ucted in compliance with all adopted codes. <br />Sincerely, <br />/-�`'� �-�-----^ <br />JefF Heilman <br />Development Technician <br />425-257-8976 � <br />Email: iheilman@ci.everett.wa.us <br />S:\1Common\Clerical\JHeilman\C1303-010 (1526 Oakes Ave) (2).doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.