Faber Construction Corp 9/27/2016
>
Contracts
>
Capital Contract
>
Faber Construction Corp 9/27/2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2017 11:58:56 AM
Creation date
10/13/2016 11:42:20 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Faber Construction Corp
Approval Date
9/27/2016
Council Approval Date
8/17/2016
Department
Public Works
Department Project Manager
Richard Hefti
Subject / Project Title
Water Main Q Broadway
Public Works WO Number
UP 3612
Tracking Number
0000297
Total Compensation
$721,228.06
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Faber Construction Corporation 4/11/2017 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Faber Construction Corporation 5/15/2017 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
244
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT SPECIAL PROVISIONS <br /> 9-23.6 Chemical Admixtures for Concrete <br /> Supplement 9-23.6 by adding the following: <br /> 9-23.6(10) Integral Coloring Agent <br /> (******) <br /> Provide integral coloring agent "Silver Smoke" as manufactured by Davis Colors, <br /> "Dover Grey" as manufactured by Solomon Colors, or equal. <br /> 9-29 ILLUMINATION, SIGNAL, ELECTRICAL <br /> 9-29.2 Junction Boxes, Cable Vaults, and Pull Boxes <br /> 9-29.2(1) Standard Duty and Heavy-Duty Junction Boxes <br /> 9-29.2(1)A Standard Duty Junction Boxes <br /> Supplement 9-29.2(1)A by adding the following: <br /> Treat both the slip-resistant lid and slip-resistant frame with Mebac#1 as <br /> ' manufactured by IKG industries, or SIipNOT Grade 3-coarse as manufactured <br /> by W.S. Molnar Co. The slip-resistant treatment may be omitted on that <br /> portion of the frame where the exposed portion of the frame is 1/2 inch wide <br /> or less. Identify the slip-resistant lid with permanent marking on the <br /> underside indicating the type of surface treatment ("M1" for Mebac#1; or "S3" <br /> for SIipNOT Grade 3-coarse) and the year manufactured. Form the <br /> permanent marking using a line consisting of a 1/8 inch thick stainless steel <br /> welded bead. <br /> 9-29.3 Fiber Optic Cable, Electrical Conductors, and Cable <br /> 9-29.3(2) Electrical Conductors and Cable <br /> Revise 9-29.3(2)F to read as follows: <br /> 9-29.3(2)F Detector Loop Wire <br /> Provide 14 AWG stranded copper conductors conforming to IMSA Specification <br /> 61-7 with cross-linked polyethylene (XLPE) insulation encased in a polyethylene <br /> outer jacket (PE tube). <br /> 9-30 WATER DISTRIBUTION MATERIALS <br /> 9-30.1 Pipe <br /> 9-30.1(1) Ductile Iron Pipe <br /> Revise 9-30.1 to read as follows: <br /> 1. Provide ductile iron pipe Special Class 52 meeting the requirements of AWWA <br /> C151 with a cement mortar interior lining and a 1-mil thick exterior seal coat <br /> meeting the requirements of AWWA C104. <br /> 2. Provide rubber gasket type, push on type, or mechanical type non-restrained <br /> ' joints meeting the requirements of AWWA C111. <br /> 3. Provide flanged joints meeting the requirements of AWWA C115. <br /> 4. Restrained joints shall be as specified in Section 9-30.2(6). <br /> 9-30.2 Fittings <br /> 9-30.2(6) Restrained Joints <br /> Supplement 9-30.2(6) by adding the following: <br /> Provide "MegaLug® Series 1100" mechanical restrained joints as manufactured <br /> by EBAA Iron, or equal. <br /> 9-30.3 Valves <br /> ' Revise 9-30.3 to read as follows: <br /> Water Main Replacement"Q" Division 9 -MATERIALS July 8, 2016 <br /> -Broadway <br /> WO No.—UP3612 SP-175 <br />
The URL can be used to link to this page
Your browser does not support the video tag.