Laserfiche WebLink
NOTES: (UNLESS OTHERWISE SPECIFIED) <br /> ®� <br /> 1. ALL CONDUIT RUNS INCLUDE INSULATED BUSHINGS AND PULL STRINGS. <br /> 2. CONDUIT RUNS CANNOT EXCEED 50'FROM END-TO-END. DO NOT EXCEED FOUR(4) 90 DEGREE BENDS. <br /> 3. CABLES BETWEEN ITEMS OVER 50 FEET IN LENGTH ARE PROVIDED BY THE CUSTOMER/CONTRACTOR. PLEASE <br /> REFER TO EQUIPMENT LIST FOR CABLE SPECIFICATIONS, <br /> 4. THE PRE-INSTALL MANUAL REQUIREMENTS SUPERSEDE ALL PRE-INSTALL NOTES IN THIS DRAWING PACKAGE.. <br /> S <br /> B VISUM LED SURGICAL LIGHT D2 TELETOM TP-622(EQUIPMENT BOOM) <br /> CONDUIT: REFER TO ROOM LAYOUT FOR CONDUIT SIZE.TERMINATE ALL CONDUITS E3 TELETOM TP-612 (ANESTHESIA BOOM) <br /> WITHIN 18"OF THE CENTER OF THE CEILING MOUNT. E4 TELETOM TP-612(ANESTHESIA BOOM) Q Q <br /> POWER: NO ADDITIONAL POWER REQUIRED. CONDUIT: REFER TO ROOM LAYOUT FOR CONDUIT SIZE.TERMINATE ALL CONDUITS w cos <br /> ACCESS PANEL: ONE (1) 24"X 24"ACCESS PANEL ADJACENT TO SUSPENSION. a o E <br /> WITHIN 18"OF THE CENTER OF THE CEILING MOUNT. w o 0 <br /> STRUCTURAL: STRYKER PRE-INSTALL PLATE SHALL BE INSTALLED BY POWER: o o^0 u <br /> REFER TO TELETOM MANUFACTURING SERVICE MODULE DRAWING FOR 0 W <br /> CUSTOMER/CONTRACTOR AT 4"ABOVE FINISHED CEILING PER CUSTOMER PROVIDED ELECTRICAL CIRCUIT COUNT.ALL ELECTRICAL CIRCUITS SHALL BE CONNECTED TO <w W a z <br /> — <br /> STRUCTURAL ENGINEER SPECS. o3z <br /> TELETOM OUTLET BOX. 2 o LL <br /> - A 21" CIRCULAR HOLE CENTERED ON STRYKER PER-INSTALL PLATE IN THE FINISHED - THE CONTRACTOR/ELECTRICIAN TO HARDWIRE STRYKER ELECTRICAL WHIP DURING <br /> CEILING IS REQUIRED FOR INSTALLATION. A 24" DIAMETER CEILING COVER STRYKER INSTALLATION. <br /> CONCEALS HOLE AFTER SUSPENSION IS INSTALLED. PLUMBING:INSTALL VALVE BRIDGE TO TOP OF PRE-INSTALL PLATE.ALL GAS LINES rc a a <br /> - THE CONTRACTOR/ELECTRICIAN TO HARDWIRE STRYKER ELECTRICAL WHIP DURING MUST BE TERMINATED WITH STRYKER SUPPLIED GAS RISERS BY CUSTOMER/MEDGAS o . 0 <br /> STRYKER INSTALLATION. INSTALLER. a m 0 <br /> > _ <br /> - ALL FINAL DISS CONNECTIONS TO BE MADE BY CUSTOMER/MEDGAS INSTALLER oc ffi o � 'z <br /> C VISUM LED SURGICAL LIGHT&FLAT PANEL ARM AFTER STRYKER INSTALLATION. � ? w < <br /> CONDUIT: REFER TO ROOM LAYOUT FOR CONDUIT SIZE. TERMINATE ALL CONDUITS ACCESS PANEL:ONE (1) 24"X 24"ACCESS PANEL ADJACENT TO SUSPENSION. ON o < Z o <br /> WITHIN 18"OF THE CENTER OF THE CEILING MOUNT. THE OUTLET BOX SIDE OF THE MOUNTING PLATE. Lb <br /> ° w <br /> POWER: ONE (1) -20 AMP CIRCUIT LOCATED AT JUNCTION BOX WITHIN 18"OF CENTERj g < m <br /> STRUCTURAL:TELETOM PRE-INSTALL PLATE SHALL BE INSTALLED BY a F w <br /> OF STRYKER PRE-INSTALL PLATE. CUSTOMER/CONTRACTOR AT 2.5-INCH,±.I 25-INCH ABOVE FINISHED CEILING PER m u+ o O Y <br /> - THE CONTRACTOR /ELECTRICIAN TO HARDWIRE STRYKER ELECTRICAL WHIP DURINGN o g < Z 2 <br /> CUSTOMER PROVIDED STRUCTURAL ENGINEER SPECS. v, = = 0 <br /> STRYKER INSTALLATION. - A 22"SQUARE HOLE CENTERED ON STRYKER PRE-INSTALL PLATE IN THE FINISHED �, 0 <br /> ACCESS PANEL: ONE (1) 24"X 24"ACCESS PANEL ADJACENT TO SUSPENSION. H O z o N <br /> U W o 2 Z <br /> CEILING IS REQUIRED FOR INSTALLATION. A 23.5"SQUARE CEILING COVER a <br /> STRUCTURAL:STRYKER PRE-INSTALL PLATE SHALL BE INSTALLED BY CONCEALS HOLE AFTER SUSPENSION IS INSTALLED. ' o w o 0 <br /> CUSTOMER/CONTRACTOR AT 4"ABOVE FINISHED CEILING PER CUSTOMER PROVIDED u :z2 0 <br /> Z O w <br /> U Z U <br /> STRUCTURAL ENGINEER SPECS. H TWO-BAY DOCUMENTATION STATION o o r- <br /> - A 21" CIRCULAR HOLE CENTERED ON STRYKER PER-INSTALL PLATE IN THE FINISHED POWER: RECOMMEND SIX (6) -20 AMP CIRCUITS o o 0 3 <br /> - CEILING IS REQUIRED FOR INSTALLATION. A 24" DIAMETER CEILING COVER - ONE (1) CIRCUIT FOR QUAD OUTLET IN LOWER SECTION BEHIND VIDEO ROUTER. ° <br /> CONCEALS HOLE AFTER SUSPENSION IS INSTALLED. - ONE (1) CIRCUIT FOR QUAD OUTLET IN LOWER SECTION BEHIND LIGHT PSB (IF Lu o w ° <br /> - THE CONTRACTOR/ELECTRICIAN TO HARDWIRE STRYKER ELECTRICAL WHIP DURING o = z <br /> STRYKER INSTALLATION. REQUIRED). o w o <br /> - ONE (1) CIRCUIT FOR DUPLEX OUTLET IN LOWER SECTION UNDER TOUCH PANEL. .o Y O _o <br /> N Y <br /> D EQUIPMENT BOOM(1000/1000) - ONE (1) CIRCUIT FOR QUAD OUTLET IN MIDDLE SECTION BEHIND DIGITAL CAPTURE 3 <br /> DEVICE. <br /> E1 ANESTHESIA BOOM(1000/1000) <br /> E2 ANESTHESIA BOOM(1000/1000) - ONE (1) CIRCUIT FOR QUAD OUTLET IN UPPER LEFT SECTION (IF REQUIRED).CONDUIT: REFER TO ROOM LAYOUT FOR CONDUIT SIZE. TERMINATE ALL CONDUITS - ONE (1) CIRCUIT FOR QUAD OUTLET IN UPPER RIGHT SECTION (IF REQUIRED). <br /> - ALL DOCUMENTATION STATION CIRCUITS REQUIRE CRITICAL POWER. <br /> WITHIN 18"OF THE CENTER OF THE CEILING MOUNT. DATA: PER LISTED EQUIPMENT. w <br /> POWER: REFER TO FLEXIS MANUFACTURING ELEVATIONS FOR ELECTRICAL CIRCUIT BACKBOX: PER LISTED EQUIPMENT. � <br /> COUNT.ALL ELECTRICAL CIRCUITS SHALL BE LOCATED AT JUNCTION BOX WITHIN 18" NOTE:CUSTOMER/CONTRACTOR RESPONSIBLE FOR RECEIVING AND INSTALLATION w U <br /> OF CENTER OF STRYKER PRE-INSTALL PLATE. OF DOCUMENTATION STATION PRIOR TO STRYKER INSTALLATION. F-- —' <br /> - THE CONTRACTOR/ELECTRICIAN TO HARDWIRE STRYKER ELECTRICAL WHIP DURING O 0 `t <br /> STRYKER INSTALLATION. z O p <br /> DOC STATION EQUIPMENT: J � Lu <br /> PLUMBING:ALL GAS LINES MUSTE BE TERMINATED WITH STRYKER SPPLIED GAS RISERS BY <br /> CUSTOMER/MEDGAS INSTALLER. SPI-3 TOUCH PANEL,22" Q Z <br /> - CHECK VALVES MUST BE ATTACHED TO A GAS MOUNTING BRACKET WITHIN 18" OF <br /> CENTER OF STRYKER PRE-INSTALL PLATE. DIMENSIONS: 20.3"W X 15.8"H X 13.5"D WITH STAND Z O <br /> DATA: NONE <br /> - STRYKER SUPPLIED BRAKE REGULATOR INSTALLED BY CUSTOMER/MEDGAS INSTALLER BACKBOX: NONE Lu � w <br /> IN AN ORIENTATION THAT THE GAUGE CAN BE READ FROM THE ACCESS PANEL. O w <br /> - ALL FINAL DISS CONNECTIONS TO BE MADE BY CUSTOMER/MEDGAS INSTALLER SDC3 a Z <br /> AFTER STRYKER INSTALLATION. DIMENSIONS: 12.5"W X 7.25"H X 16.5"D p 3 <br /> ACCESS PANEL: ONE (1) 24"X 24"ACCESS PANEL ADJACENT TO SUSPENSION. DATA: ONE (]) ETHERNET CONNECTION > rz <br /> STRUCTURAL:STRYKER PRE-INSTALL PLATE SHALL BE INSTALLED BYBACKBOX: NONE O W <br /> a o <br /> CUSTOMER/CONTRACTOR AT 4"ABOVE FINISHED CEILING PER CUSTOMER PROVIDED Lu <br /> STRUCTURAL ENGINEER SPECS. SDP1000 PRINTER of <br /> - A 21" CIRCULAR HOLE CENTERED ON STRYKER PER-INSTALL PLATE IN THE FINISHED DIMENSIONS: 12.5"W X 8.2"H X 16.7"D REP:JEFF ELDEREGE <br /> CEILING IS REQUIRED FOR INSTALLATION. A 24" DIAMETER CEILING COVER DATA: NONE PN:DENNIS MARSHAL <br /> CONCEALS HOLE AFTER SUSPENSION IS INSTALLED. BACKBOX: NONE <br /> - THE CONTRACTOR /ELECTRICIAN TO HARDWIRE STRYKER ELECTRICAL WHIP DURING SHEET: <br /> STRYKER INSTALLATION. D <br /> AUTOCAD DRAWING TEMPLATE I TEM IOOXX I REV.A r <br /> PLOT STAMP:MONTGOMERY,ERIC I DATE:11/30/2015 2:07 PM + <br />