_ Residential Photovoltaic ®TC Permit Application <br /> Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed <br /> in this Checklist.All project plans and supporting documentation must be provided on site for the inspector. <br /> -------- O BE COMPLETED BY APPLICANT------- <br /> Project Informm cation <br /> Property Owner Name: Ccf__dkin, t �d <br /> Project Address: Parcel# <br /> City; , tLv State: ZIP: <br /> Day Phone: <br /> Contractor Name <br /> Contractor License#: <br /> Contractor Day Phone: 'Ar' C16 <br /> PVsystern description (3c)) —z- C, <br /> (include manufacturer <br /> and model#of PV � �- �U�P�(L 1,�-t��S2S �l �� '��( T_ <br /> modules and r ' <br /> inverters): �� <br /> 3 ®eviyd d��im�� 1-11 Vziur project. qua91oies fob-expedited pernI 0511: <br /> Yes No <br /> 1. PV system is designed and proposed for a detached one-or two-family dwelling or <br /> townhouse not more than three stories above grade or detached accessory structure that ❑ <br /> is code compliant to setbacks and height, or code allows expansion of nonconformity for <br /> solar modules. [IRC 101.2] <br /> 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by ❑ <br /> the local jurisdiction. <br /> 3. Rooftop is made from lightweight material such'as a single layer of composition shingles, X <br /> Elmeta I roofing,lightweight masonry,or cedar shingles. <br /> 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.21 ❑ <br /> 5. The installation shall meet the requirements of NFPA 70 National Electric Code,and all <br /> required electrical permit(s)must be obtained from the Authority Having Jurisdiction to ❑ <br /> administer the electrical code. [IRC M2302.2] <br /> 6. The installation shall meet the requirements of the International Fire Code as amended k-1 Elby WA State. [IRC M2302.2] <br /> 7, The PV system is designed for the wind speed of the local area,and will be installed per -V-V1 <br /> 1] <br /> the manufacturer's specifications. [IRC M2302.2.1(1)] . <br /> 8. The ground snow load does not exceed 70 pounds per square foot.[IRC M2302.2.1(2)] NX ❑ <br /> 9. Total dead load of modules,supports, mountings, raceways and ail other appurtenances <br /> weigh no more than-four pounds per-square oot.-[I C M2302.2.1(3)] El <br /> Enter total dead load of system (lbs/ft <br /> 10. To address uplift,modules are mounted no higher than 18"above the surface of the ❑ <br /> roofing to which they are affixed. [IRC M2302.2.1(4)] <br />