My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST OLYMPUS HALL 2017-07-26
>
Address Records
>
TOWER ST
>
2000
>
OLYMPUS HALL
>
2000 TOWER ST OLYMPUS HALL 2017-07-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2017 2:04:55 PM
Creation date
10/21/2016 9:16:37 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
OLYMPUS HALL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
! <br />• <br />C GEOMETRY: There shall be no changes in horizontal dimension of the lateral-force-resisting system <br />of more than 30 percent in a story relative to adjacent stories for Life Safety and Immediate <br />Occupancy, excluding one-story penthouses. (Tier 2: Sec. 4.3.23) <br />C VERTICAL DISCONTINUITIES: All vertical elements in the lateral-force-resisting system shall be <br />continuous to the foundation. (Tier 2: Sec. 43.2.4) <br />All ve��tica/ elements in later•al — force — r•esisting systerns are contint�otis to focardation. <br />C MASS: There shall be no change in effective mass more than 50 percent from one story to the ncxt for <br />Life Safety and Immediate Occupancy. Light roofs, penthouses, and mezzanines need not be <br />considered. (Tier 2: Sec. 4.3.2.5) <br />C TORSION: The distance between the story center of mass and the story center of rigidity shall be less <br />than 20 percent of the building width in either plan dimension for Life Safety and Immediate <br />Occupancy. (Tier 2: Sec. 43.2.6) <br />C DETERIORATION OF CONCRETE: There shall be no visible deteriaration of concrete or reinforcing <br />steel in any of the vertical- or lateral-force-resisting elements. (Tier 2: Sec. 4.33.4) <br />Exposed concrete has no visible distress. <br />N/A POST-TENSION[NG ANCHORS: There shall be no evidence of corrosion or spalling in the vicinity of <br />post-tensioning or end fittings. Coil anchors shall not have been used. (Tier 2: Sec. 43.3.5) <br />Building has no post-tensioiiing anchors. <br />Lateral Force Resisting System <br />NC REDUNDANCY: The number of lines of moment frames in each principal direction shall be greater <br />than or equal to 2 for Life Safety and Immediate Occupancy. The number of bays of moment frames in <br />cach line shall be greater than or eyual to 2 for Life Safety and 3 for Immediate Occupancy. (Tier 2: <br />Sec. 4.4.1.1.1) <br />Numbers of lines in each principa! direction are greater or more than 2. Number of bays in E-W <br />direction momenl frames is 1. <br />C INTERFERING WALLS: All infill walls placed in moment frames shall be isolated from structural <br />elements. (Tier 2: Sec. 4.4.1.2.1) <br />Ir:fill walls are not placed in moment frames. <br />NC SHEAR STRESS CHECK: The shear stress in the concrete columns, calculated using the Quick Check <br />procedure of Section 3.5.3.2, shall be less than 100 psi or 2�f� for Life Safety and Immediate <br />Occupancy. (Tier 2: Sec. 4.4.1.4.1) <br />Sl�ear stress in concrete coh�mns of rnoment frmne is nlore than 100 psi. <br />NC AXIAL STRESS CHECK: The axial stress due to gravity loads in columns subjected to overtuming <br />forces shall be less than O.l Of� for Life Safety and Immediate Occupancy. Altematively, the axial <br />stresses due to overtuming forces alone, calculated using the Quick Check Procedurc of Section <br />3.53.6, shall be less than 0.30f< for Life Safety and Immediate occupancy. (Tier 2: Sec. 4.4.1.4.2) <br />ASCE 31-03 Seismic Evaluation of Eausting Buildings Basic Structural Checklist for C1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.