My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST OLYMPUS HALL 2017-07-26
>
Address Records
>
TOWER ST
>
2000
>
OLYMPUS HALL
>
2000 TOWER ST OLYMPUS HALL 2017-07-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2017 2:04:55 PM
Creation date
10/21/2016 9:16:37 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
OLYMPUS HALL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />3.7.85 Supplemental Structural Checklist for Building Type C1: Concrete Moment Frames <br />This Supplemental Structural Checklist shall be completed when required by Table 3-2. The Basic Structural <br />Checklist shall be completed prior to completing this Supplemental Structural Checklist. <br />Lateral Force Resisting System <br />N/A FLAT SLAB FRAMES: The lateral-force-resisting system shall not bc a frame consisting of columns <br />and a flat slab/plate without beams. (Tier 2: Sec. 4.4.1.4.3) <br />N/A PRESTRESSED FRAME ELEMENTS: The lateral-load-resisting frames shall not include any pre- <br />stressed or post-tensioned elements where the average pre-stress exceeds 700 psi or j,✓6 at potential <br />hinge locations. The average pre-stress shall be calculated in accordance with the Quick Check <br />procedure of Section 3.5.3.8. (Tier 2: Sec. 4.4.1.4.4) <br />N/A CAPTIVE COLUMNS: There shall be no columns at a level with height/depth ratios less than <br />50 percent of the nominal height/depth ratio of the typical columns at that level tior Life Safety and 75 <br />percent for Immediate Occupancy. (Tier 2: Sec. 4.4.1.4.5) <br />NC NO SHEAR FAILURES: The shear capacity of frame members shall be able to develop the moment <br />capacity at the top and bottom of the columns. (Tier 2: Sec. 4.4.1.4.6) <br />N/A STRONG COLUMN/WEAK BEAM: The sum of the moment capacity of the columns shall be 20 <br />percent greater than that of the beams at frame joints. (Tier 2: Sec. 4.4.1.4.7) <br />BEAM BARS: At least two longitudinal top and two longitudinal bottom bars shall extend <br />N/A continuously throughout the fen�th of each frame beam. At least 25 percent of the longitudinal bars <br />provided at the joinCs For either positive or negative moment shall bc continuous throughout the length <br />of the members for Life Safety and Immcdiate Occupancy. (Tier 2: Sec. 4.4.1.4.8) <br />Unknown COLUMN-BAR SPLICES: All column bar lap splice lengths shall be greater than 35 db for Life Safety <br />and 50 dn for Immediate Occupancy and shall be endosed by ties spaced at or less than 8 dn for Life <br />Safety and Immediate Occupancy. Alternatively, column bars shall be spliced with mechanical <br />couplers with a capacity of at least 1.25 times the nominal yield strength of the spliced bar. (Tier 2: <br />Sec. 4.4.1.4.9) <br />Column schedule provided on the drawings show columns doweled i�2to foundation. Details/sections are <br />not provided to show lap lengths. <br />N/A BEAM-BAR SPLICES: The lap splices or mechanical couplers for longitudinal beam reinforcing shall <br />noC be located within le/4 of the joints and shall not be located within the vicinity of potential plastic <br />hinge locations. (Tier 2: Sec. 4.4.1.4.10) <br />NC COLUMN-TIE SPACING: Frame columns shall have ties spaced at or less than d/4 for Life Safety and <br />Immediate Occupancy throughout their length and at or less than 8 dn for Life Safety and Immediate <br />Occupancy at all potential plastic hinge locations. (Tier 2: Sec. 4.4.1.4.11) <br />Cirr.i�lar coli�mns meet this requirement {�ut rectangular columns do nnt meet this requiremerit. <br />ASCE 31-03 Seismic Evaluation of Existing Buildings Supplemental Structural Checklist Cl <br />
The URL can be used to link to this page
Your browser does not support the video tag.