Laserfiche WebLink
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R' Revised Oct 2013 <br /> Project Info Project Address Powder Mill - Bldg A Date 6/18/2014 <br /> Compliance forms 36th Ave w For Building Department Use <br /> do not require a Everett, WA <br /> password to use. Applicant Name: <br /> Instructional and <br /> calculating cells are Applicant Address: <br /> write-protected. <br /> Applicant Phone: <br /> Project Description ❑✓ New Building ❑Addition ❑Alteration ❑ Change of Occupancy/Conditioning <br /> Compliance Path <br /> Q Prescriptive Q Component Performance 0 Total Building Performance <br /> Selection required to enable forms. <br /> Occupancy Group QQ Commercial O Group R-R2&R3 over 3 stories and all R1 <br /> Selection required to enable forms. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %vertical <br /> If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration <br /> enter values for vertical fenestration6216.0 — 51054.0 X 00 — 12.2$ <br /> skylights,gross walls and roof on this <br /> ENV-SUM worksheet. Ifcomplying via Gross Exterior <br /> the Component Performance path, enter <br /> these values in the ENV-UA worksheet. Total Skylight divided by Roof Area times 100 equals %Skylight <br /> These values auto-fill from ENV-UA and <br /> are write-protected on ENV-SUM. 1216.0 _ 108660. 0 X 100 = 1.1% <br /> Vertical VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Fenestration Area <br /> Compliance <br /> Skylight Area SKYLIGHT AREA COMPLIES <br /> Vertical Fenestration Q 50%or more of the floor area is within a daylight zone per C402.3.1.1 <br /> Alternates Q High Performance Fenestration U-factors and SHGC per C402.3.1.3 <br /> Compliance Method <br /> ❑Skylight area 3%or greater,VT-0.40 or greater <br /> Single Story Spaces Q Skylight effective aperture 1%or greater,provide calculation <br /> Requiring Skylights ❑Space eligible for exception <br /> Requires a minimum of 50%of floor area to be within a skylight daylight zone for specific <br /> space types.Refer to C402.3.2 for requirements. <br /> ❑ Project has semi-heated spaces as defined per C402.1.4 <br /> ❑Applying wall exception to semi-heated spaces <br /> 1. Semi-heated spaces may comply under Prescriptive or Component Performance compliance <br /> Semi-Heated Spaces path. <br /> 2.Semi-heated spaces shall be documented separately from other conditioned spaces—provide <br /> separate compliance forms for each conditioned space type. <br /> 3.Envelope elements separating semi-heated from other conditioned spaces shall comply with <br /> exterior thermal envelope requirements. <br /> ❑Walk-in Cooler ❑ Walk-in Freezer <br /> 1:1Refrigerated Warehouse Cooler EJRefrigerated Warehouse Freezer <br /> Refrigerated Spaces <br /> Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for <br /> these areas may be combined with non-refrigerated areas in the ENV-PRESCRIPTIVE form. Refer <br /> to C402.5 and C402.6 for requirements. <br /> Project includes more than one occupancy type and/or level of space conditioning.Multiple <br /> Mixed Occupancy and/or compliance forms may be required. Select all that apply to scope of project: <br /> Space Conditioning ❑ Commercial ❑ R2&R3 over 3 stories and all R1 ❑ Refrigerated Space <br /> ❑ Fully Conditioned ❑ Semi-Heated ❑ Low Energy* <br /> ❑ R2&R3-3 stories or less <br /> *Low energy areas are exempt from all thermal envelope provisions and compliance forms for <br /> these areas are not required. Refer to CIO 1.5.2 for exemption. <br /> 3�1 b <br /> Franklin Engineering 1 625 4th Ave Ste 202 1 Kirkland, WA 98033 <br />