My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6305 36TH AVE W B 2016-10-31
>
Address Records
>
36TH AVE W
>
6305
>
6305 36TH AVE W B 2016-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2021 3:57:30 PM
Creation date
10/31/2016 4:06:57 PM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6305
Unit
B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Summary Zones • <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R' Revised Oct 2013 <br /> Project Info Project Address Powder Mill - Bldg B Date 6/18/2014 <br /> Compliance forms 36th Ave W For Building Department Use <br /> do not require a Everett, WA <br /> password to use. <br /> Instructional and Applicant Name: <br /> calculating cells are Applicant Address: <br /> write-protected. <br /> Applicant Phone: <br /> Project Description New Building ❑Addition ❑Alteration ❑ Change of Occupancy/Conditioning <br /> Compliance Path <br /> Q Prescriptive Component Performance Q Total Building Performance <br /> Selection required to enable forms. <br /> Occupancy Group Q Commercial O Group R-R2&R3 over 3 stories and all R1 <br /> Selection required to enable forms. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration <br /> enter values for vertical fenestration, 42920 — 51054 . 0 X 100 — 8.4% <br /> skylights,gross walls and roof on this . <br /> ENV-SUM worksheet. Ifcomplying via Gross Exterior <br /> the Component Performance path, enter <br /> these values in the ENV-UA worksheet. Total Skylight divided by Roof Area times 100 equals %Skylight <br /> These values auto-fill from ENV-UA and <br /> are write-protected on ENV-SUM. 1280.0 — 119145.0 X 100 = 1.1% <br /> Vertical VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Fenestration Area <br /> Compliance <br /> Skylight Area SKYLIGHT AREA COMPLIES <br /> Vertical Fenestration Q 50%or more of the floor area is within a daylight zone per C402.3.1.1 <br /> Alternates O High Performance Fenestration U-factors and SHGC per C402.3.1.3 <br /> Compliance Method <br /> ❑Skylight area 3%or greater,VT-0.40 or greater <br /> Single Story Spaces Skylight effective aperture 1%or greater,provide calculation <br /> Requiring Skylights ❑Space eligible for exception <br /> Requires a minimum of 50%of floor area to be within a skylight daylight zone for specific <br /> space types.Refer to C402.3.2 for requirements. <br /> ❑ Project has semi-heated spaces as defined per C402.1.4 <br /> ❑Applying wall exception to semi-heated spaces <br /> 1.Semi-heated spaces may comply under Prescriptive or Component Performance compliance <br /> Semi-Heated Spaces path. <br /> 2.Semi-heated spaces shall be documented separately from other conditioned spaces—provide <br /> separate compliance forms for each conditioned space type. <br /> 3.Envelope elements separating semi-heated from other conditioned spaces shall comply with <br /> exterior thermal envelope requirements. <br /> ❑Walk-in Cooler ❑ Walk-in Freezer <br /> [—] Refrigerated Warehouse Cooler E] Refrigerated Warehouse Freezer <br /> Refrigerated Spaces <br /> Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for <br /> these areas may be combined with non-refrigerated areas in the ENV-PRESCRIPTIVE form. Refer <br /> to C402.5 and C402.6 for requirements. <br /> Project includes more than one occupancy type and/or level of space conditioning.Multiple <br /> Mixed Occupancy and/or compliance forms may be required. Select all that apply to scope of project: <br /> Space Conditioning ❑ Commercial ❑ R2&R3 over 3 stories and all R1 ❑ Refrigerated Space <br /> ❑ Fully Conditioned ❑ Semi-Heated ❑ Low Energy' <br /> ❑ R2&R3-3 stories or less <br /> 'Low energy areas are exempt from all thermal envelope provisions and compliance forms for <br /> these areas are not required. Refer to C101.5.2 for exemption. <br /> 3 � <br /> Franklin Engineering 1 625 4th Ave Ste 202 1 Kirkland, WA 98033 <br />
The URL can be used to link to this page
Your browser does not support the video tag.