My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6305 36TH AVE W B 2016-10-31
>
Address Records
>
36TH AVE W
>
6305
>
6305 36TH AVE W B 2016-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2021 3:57:30 PM
Creation date
10/31/2016 4:06:57 PM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6305
Unit
B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Component Performance Path, pg. 1 Zones 4c/5b EN <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address Powder Mill - Bldg B Date 06/18/2014 <br /> Occupancy Group Q Commercial Q Group R For Building Department Use <br /> Change in occupancy or space conditioning O <br /> Note-Proposed UA may exceed Target UA by 10%per C101.4.4 and C101.4.5 <br /> Fenestration Area as%gross above-grade wall area 8.4% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 1.1% Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:U-factors shall come from Appendix A, Chapter C303,or calculated per approved method as specified in C402.1.2. <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor,page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> _777 -Y R=30 ID:Min.rigid above roof 0.032 117865 3771.7 0,034 117865 4007.4 <br /> a R= ID: Above Deck Insulation U-0.034 <br /> 0 <br /> R= ID: <br /> a R= ID: 0.031 <br /> o co R= ID: Metal Building U-0.031 <br /> R= ID: <br /> R= ID: 0.021 <br /> R= ID: Single raft,attic,other U-0.021 <br /> O R= ID: <br /> R= ID: 0.055 <br /> R= ID: Steel/metal frame U-0.055 <br /> R= ID: <br /> o a R= ID: 0.052 <br /> R= ID: Metal Building U-0.052 <br /> N R= ID: <br /> R= ID: 0.054 <br /> o R= ID: Wood Frame,other U-0.054 <br /> a o <br /> n 3: R= ID: <br /> O <br /> R=21 ID:6"metal,24"oc,air gap 0.090 43483 3913.5 0.104 I 43483 4522.2 <br /> CU <br /> R= ID:or R-11 stickpins Mass Wall U-0.104 <br /> :5 R= ID: <br /> 0 R= ID: 0.104 <br /> m <br /> o R= ID: Assumed to be Mass Wall U-0.104 <br /> a�a <br /> m � R= ID: <br /> (7 R= ID: <br /> m R= ID: 0.031 <br /> U) R= ID: Mass Floor U-0.031 <br /> o 2i R= ID: <br /> FLs <br /> LL R=21 ID:Metal studs 0.110 245 27.0 0.029 245 7.1 <br /> E R= ID: Joist/Framing U-0.029 <br /> ii R= ID: <br /> F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R= ID:No insulation 0.730 1778 1297.9 0-540 1778 960.1 <br /> a L Slab-On-Grade U-0.54 <br /> R= ID: <br /> m <br /> R= ID: <br /> R= ID: 0.550 <br /> Fn R= ID: Heated Slab-On-Grade U-0.55 <br /> = R= ID: <br /> *Proposed non-residential CMU walls meeting Table C402.1.2 Area UA Area UA <br /> Footnote D requirements can use the target U-value of 0.104 rather Page 1 <br /> than Appendix A values.Show footnote requirements in plans. SubtotalF1633-71 9010 163371 9497 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Franklin Engineering 1 625 4th Ave Ste 202 1 Kirkland, WA 98033 <br />
The URL can be used to link to this page
Your browser does not support the video tag.