Laserfiche WebLink
I <br /> i <br /> 1 <br /> I 2 Fiber Management Tray <br /> 3 The Contractor shall provide and install one fiber management tray for each <br /> 4 preterminated patch panel installed. <br /> II 5 <br /> 6 Fiber Optic Connector <br /> 7 Unless otherwise noted in the Plans, all fiber optic connectors shall meet the <br /> 8 following: <br /> I 9 All fiber optic connectors shall be LC/UPC (55dB) in accordance with Telcordia 6R- <br /> 10 326. All shall be factory connectorized. <br /> 11 <br /> I 12 Ethernet Switch <br /> 13 Ethernet communication equipment will be supplied by the Contracting Agency It <br /> 14 will be manufactured by GarretCom, Inc., and installed at locations shown in the <br /> I 15 Plans. All connectors will be LC/UPC (55dB) in accordance with Telcordia 6R-326. <br /> 16 All patch cords shall be Contractor provided and shall be factory connectorized. <br /> 17 Four factory connectorized 6' Ethernet cables and 4 6' fiber patch cords shall be <br /> I18 provided with each switch <br /> 19 <br /> 20 Equipment Model Numbers: <br /> I Description Part Numbers (both Parts are <br /> required) <br /> 8-Port Ruggedized Switch 6KQE-AC with five RJ-45 <br /> connectors and two gigabit LX-10 <br /> I SFPs with LC/UPC fiber <br /> connectors <br /> 21 <br /> I 22 Fiber Optic Connector <br /> 23 Unless otherwise noted in the Plans, all fiber optic connectors used on this project <br /> 24 shall meet the following: <br /> I 25 <br /> 26 All shall be LC/UPC (55dB) in accordance with Telcordia 6R-326 <br /> 27 All shall be factory-connectorized <br /> 28 <br /> I 29 Fiber Optic Cable Lubricant <br /> 30 Fiber optic cable lubricant shall be as follows: <br /> 31 <br /> I 32 Compatible with the cable jacket <br /> 33 Non-combustible <br /> 34 Water-based leaving little or no residue <br /> I 35 <br /> 36 Fiber Optic Splice Closure <br /> 37 All fiber optic splice closures shall be re-enterable and reusable and be designed <br /> I 38 for use on fiber optic cables in an underground, submerged environment. All splice <br /> 39 closures shall be rated for 1310 and 1550 nanometer wavelengths. Splice <br /> 40 closures shall contain a valve to allow pressurization of the housing. <br /> I 41 <br /> 42 All below ground splices shall be contained in waterproof splice closures. Splices <br /> 43 shall utilize two half shells bolted together with stainless steel bolts and be fitted <br /> 44 with a neoprene gasket. Selected splices shall not require a re-entry kit. Upon <br /> I <br /> I 4151 STREET TO WMVD FREIGHT <br /> CORRIDOR IMPROVEMENTS <br /> FED AID#STPUL-9931(012);PW#3472 SP-103 February 10,2016 <br />