Laserfiche WebLink
I <br /> I <br /> 1 shall be wired in series. The loop detector lead-in cable shall be pulled into <br /> I 2 the controller cabinet and connected to the detector channel terminals as <br /> 3 indicated in the loop detector schedule in the plans. <br /> 4 <br /> I <br /> 5 <br /> 6 Loop Detector Lead-In Cable (2 or 3 pair) <br /> Two or three pair loop detector lead-in cable shall be installed where shown in <br /> 7 the wiring schedule in the plans. Belden 1037A and 1055A cables are a pre- <br /> 8 approved source. Other cables may be submitted for approval consistent with <br /> 111 9 the following specifications: Multi pair loop detector lead-in cable shall consist <br /> 10 of two or three individually twisted and shielded pairs of #16 AWG stranded <br /> 11 copper wire, surrounded by an outer jacket of polyvinyl chloride (PVC). Each <br /> 12 pair shall also contain a stranded copper drain wire and shall be individually <br /> 13 shielded with an aluminum polyester foil shield. <br /> 14 <br /> I 15 <br /> 16 diffi iri 9 29 Rijrr ETE ETE CTOR LOUP WIRE RTF <br /> 17 Detector Loop Wire <br /> I18 Section 9-29.3(2)F is revised to read as follows: <br /> 19 <br /> 20 Detector loop wire shall use 14 AWG stranded copper conductors, and shall <br /> I 21 conform to IMSA Specification 51-7, with cross-linked polyethylene (XLPE) <br /> 22 insulation encased in a polyethylene outer jacket (PE tube). <br /> 23 <br /> I 24 <br /> +� a+z-•g.a. .� t n^-�r•-•m c,iN�rT^a�m"+t v^a. ,�m�.�«cR�..a finw-2m �m+:�,a <br /> 25 CNH 8 2® 2(9s�293( ))VIDEO�DETEC,T�IONCABLE RTF <br /> 26 Electrical Conductors and Cable <br /> I 27 Section 9-29.3(2) is supplemented with the following: <br /> 28 <br /> 29 Video Detection Cable <br /> I 30 Coaxial cable or combination (composite/Siamese) cable for video detection shall <br /> 31 be RG59/U with a manufacturer's rating of 600 Volts (Non UL - manufacturer's <br /> 32 voltage rating of the insulation is acceptable). Combination cable shall be in <br /> I 33 accordance with the video detection system manufacturer's recommendations for <br /> 34 the length of cable required. <br /> 35 <br /> 36 <br /> I 37 8` 202296; CR8 <br /> 38 Light And Signal Standards <br /> 39 Section 9-29.6 is supplemented with the following: <br /> I40 <br /> 41 $rO. (9 29Tard#01: R8_, <br /> I 42 (April 6, 2015) <br /> 43 Light Standards with Type 1 Luminaire Arms <br /> 44 Lighting standards shall be fabricated in conformance with the methods and <br /> 45 materials specified on the pre-approved Plans listed below, provided the following <br /> I 46 requirements have been satisfied: <br /> 47 <br /> I <br /> I 4151 STREET TO WMVD FREIGHT <br /> CORRIDOR IMPROVEMENTS <br /> FED AID#STPUL-9931(012); PW#3472 SP-111 February 10,2016 <br />