Marshbank Construction 5/9/2016
>
Contracts
>
Capital Contract
>
Marshbank Construction 5/9/2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2018 9:23:23 AM
Creation date
5/20/2016 10:28:35 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Marshbank Construction
Approval Date
5/9/2016
Council Approval Date
4/16/2016
Department
Public Works
Department Project Manager
Ryan Sass
Subject / Project Title
41st St to W Marine View Dr Corridor Imprvts
Public Works WO Number
PW 3472
Tracking Number
0000049
Total Compensation
$2,758,753.00
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Marshbank Construction 1/25/2017 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
MARSHBANK CONSTRUCTION 3/26/2018 Change Order 3
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Marshbank Construction 6/26/2017 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> 1 recommended by the admixture manufacturer. To ensure uniform color, <br /> 2 texture, and quality, all mortar mix components shall be obtained from one <br /> I <br /> 3 manufacturer for each component, and from one source and producer for each <br /> 4 aggregate. <br /> 5 <br /> I <br /> 6 Geosynthetic Soil Reinforcement <br /> 7 Geogrid reinforcement shall conform to Section 9-33.1, and shall be a product <br /> 8 listed in Appendix D of the current WSDOT Qualified Products List (QPL). The <br /> 9 values of Tar and To as listed in the QPL for the products used shall meet or <br /> 10 exceed the values required for the wall manufacturer's reinforcement design <br /> 11 as specified in the structural earth wall design calculation and working drawing <br /> 12 submittal. I 13 <br /> 14 The minimum ultimate tensile strength of the geogrid shall be a minimum <br /> 15 average roll value (the average test results for any sampled roll in a lot shall I 16 meet or exceed the values shown in Appendix D of the current WSDOT QPL). <br /> 17 The strength shall be determined in accordance with ASTM D 6637, for multi- <br /> 18 rib specimens. I 19 <br /> 20 The ultraviolet (UV) radiation stability, in accordance with ASTM D 4355, shall <br /> 21 be a minimum of 70 percent strength retained after 500 hours in the <br /> 22 weatherometer. <br /> 23 <br /> 24 The longitudinal (i.e., in the direction of loading) and transverse (i.e., parallel to <br /> 25 the wall or slope face) ribs that make up the geogrid shall be perpendicular to <br /> I <br /> 26 one another. The maximum deviation of the cross-rib from being <br /> 27 perpendicular to the longitudinal rib (skew) shall be no more than 1 inch in 5 <br /> 28 feet of geogrid width. The maximum deviation of the cross-rib at any point I 29 from a line perpendicular to the longitudinal ribs located at the cross-rib (bow) <br /> 30 shall be 0.5 inches. <br /> 31 <br /> 32 The gap between the connector and the bearing surface of the connector tab <br /> 33 cross-rib shall not exceed 0.5 inches. A maximum of 10 percent of connector <br /> 34 tabs may have a gap between 0.3 inches and 0.5 inches. Gaps in the <br /> I <br /> 35 remaining connector tabs shall not exceed 0.3 inches. <br /> 36 <br /> 37 The Engineer will take random samples of the geogrid materials at the job site. <br /> 38 Approval of the geogrid materials will be based on testing of samples from <br /> I <br /> 39 each lot. A "lot" shall be defined as all geogrid rolls sent to the project site <br /> 40 produced by the same manufacturer during a continuous period of production <br /> 41 at the same manufacturing plant having the same product name. The I 42 Contracting Agency will require 14 calendar days maximum for testing the <br /> 43 samples after their arrival at the WSDOT Materials Laboratory in Tumwater, <br /> 44 WA. I 45 <br /> 46 The geogrid samples will be tested for conformance to the specified material <br /> 47 properties. If the test results indicate that the geogrid lot does not meet the <br /> I <br /> 48 specified properties, the roll or rolls which were sampled will be rejected. Two <br /> 49 additional rolls for each roll tested which failed from the lot previously tested <br /> 50 will then be selected at random by the Engineer for sampling and retesting. If <br /> 51 the retesting shows that any of the additional rolls tested do not meet the <br /> I <br /> 4151 STREET TO WMVD FREIGHT I CORRIDOR IMPROVEMENTS <br /> FED AID#STPUL-9931(012);PW#3472 SP-90 February 10,2016 <br />