My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ariston Pacific, Inc. 5/9/2016
>
Contracts
>
Capital Contract
>
Ariston Pacific, Inc. 5/9/2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2017 10:38:43 AM
Creation date
5/20/2016 11:08:02 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Ariston Pacific, Inc.
Approval Date
5/9/2016
Council Approval Date
2/24/2016
Department
Public Works
Department Project Manager
Ryan Sass
Subject / Project Title
Pacific & Broadway/Citywide Safety Impvts
Public Works WO Number
PW3523 & PW3524
Tracking Number
0000050
Total Compensation
$1,062,314.79
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Ariston Pacific, Inc. 4/17/2017 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Public Works 10/18/2016 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
457
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> 1 <br /> ' 2 6-13.3(2) Submittals <br /> 3 In the first paragraph, the first sentence is revised to read: <br /> 4 <br /> 5 The Contractor, or the supplier as the Contractor's agent, shall furnish a Manufacturer's <br /> 6 Certificate of Compliance certifying that the structural earth wall materials conform to <br /> 7 the specified material requirements. <br /> 8 <br /> 9 The second paragraph is revised to read: <br /> 10 <br /> 11 A Type 1 Working Drawing of all test results, performed by the Contractor or the <br /> ' 12 Contractor's supplier, which are necessary to assure compliance with the specifications, <br /> 13 shall submitted along with each Manufacturer's Certificate of Compliance. <br /> 14 <br /> 15 In the third paragraph, the first sentence is revised to read: <br /> 16 <br /> 17 Before fabrication, the Contractor shall submit a Type 1 Working Drawing consisting of <br /> ' 18 <br /> 19 the field construction manual for the structural earth walls, prepared by the wall <br /> manufacturer. <br /> 20 <br /> 21 In the fourth paragraph, the first sentence is revised to read: <br /> 22 <br /> 23 The Contractor, through the license/patent holder for the structural earth wall system, <br /> 24 shall submit Type 2E Working Drawings consisting of detailed design calculations and <br /> ' 25 details. <br /> 26 <br /> 27 The last paragraph is deleted. <br /> ' 28 <br /> 29 6-13.3(3) Excavation and Foundation Preparation <br /> 30 In the first paragraph, the last two sentences are revised to read: <br /> ' 31 <br /> 32 The foundation for the structure shall be graded level for a width equal to or exceeding <br /> 33 the length of reinforcing as shown in the structural earth wall working drawings and, for <br /> 34 walls with geogrid reinforcing, in accordance with Section 2-12.3. Prior to wall <br /> 35 construction, the foundation, if not in rock, shall be compacted as accepted by the <br /> 36 Engineer. <br /> 37 <br /> 38 6-13.3(6) Welded Wire Faced Structural Earth Wall Erection <br /> 39 The first two sentences are revised to read: <br /> ' 40 <br /> 41 The Contractor shall erect the welded wire wall reinforcement in accordance with the <br /> 42 wall manufacturer's field construction manual. Construction geotextile for wall facing <br /> 43 shall be placed between the backfill material within the reinforced zone and the coarse <br /> 44 granular material immediately behind the welded wire wall facing, as shown in the Plans <br /> 45 and the structural earth wall working drawings. <br /> 46 <br /> ' 47 6-13.3(7) Backfill <br /> 48 The third paragraph is revised to read: <br /> 49 <br /> 50 Misalignment or distortion of the precast concrete facing panels or concrete blocks due <br /> 51 to placement of backfill outside the limits of this specification shall be corrected in a <br /> 52 manner acceptable to the Engineer. <br /> AMENDMENTS TO THE 2014 STANDARD SPECIFICATIONS BOOK <br /> Revised: 8/3/15 <br />
The URL can be used to link to this page