My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ariston Pacific, Inc. 5/9/2016
>
Contracts
>
Capital Contract
>
Ariston Pacific, Inc. 5/9/2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2017 10:38:43 AM
Creation date
5/20/2016 11:08:02 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Ariston Pacific, Inc.
Approval Date
5/9/2016
Council Approval Date
2/24/2016
Department
Public Works
Department Project Manager
Ryan Sass
Subject / Project Title
Pacific & Broadway/Citywide Safety Impvts
Public Works WO Number
PW3523 & PW3524
Tracking Number
0000050
Total Compensation
$1,062,314.79
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Ariston Pacific, Inc. 4/17/2017 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Public Works 10/18/2016 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
457
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 Precast Structures with an overall span length greater than 20-feet (measured <br /> I <br /> 2 along the centerline of Roadway from inside face to inside face of hydraulic , <br /> 3 opening) shall be designed for seismic loads in accordance with FHWA-NHI- <br /> 4 10-034, Technical Manual for Design and Construction of Road Tunnels—Civil <br /> 5 Elements, Chapter 13. The AASHTO LRFD Bridge Design Specifications <br /> 6 Section 12.6.1 exemption from seismic loading does not apply. The design <br /> I <br /> 7 shall evaluate the seismic effects of transient racking deformations. <br /> 8 <br /> 9 Wingwalls, cutoff walls, and headwalls associated with the precast Structures <br /> 10 shall be designed in accordance with the WSDOT Geotechnical Design <br /> 11 Manual (M46-03) and Chapter 11 of AASHTO LRFD Bridge Design <br /> 12 Specifications, latest edition and current interims in effect on the Bid <br /> 13 advertising date, including seismic loads. <br /> 14 <br /> 15 The Contractor shall use the geotechnical report prepared for this project and <br /> 16 available through the source(s) specified in the Special Provisions under <br /> 17 Section 1-02.4(2). <br /> 18 <br /> 19 Whenever the minimum finished backfill or surfacing depth above the top of <br /> 20 the Structure is less than 1'-0" (except when the top of the Structure is directly <br /> 21 exposed to vehicular traffic), either all steel reinforcing bars in the span unit <br /> 22 shall be epoxy-coated with 1-1/2" minimum concrete cover from the face of <br /> 23 concrete to the face of the top mat of steel reinforcing bars, or the minimum <br /> 24 concrete cover shall be 2-1/2". Whenever the top of the Structure is directly <br /> 25 exposed to vehicular traffic, all steel reinforcing bars in the span unit shall be <br /> 26 epoxy-coated and the minimum concrete cover dimension from face of <br /> 27 concrete to the face of the top mat of steel reinforcing bars shall be 2-1/2". <br /> 28 Concrete cover from the face of any concrete surface to the face of any steel <br /> 29 reinforcement shall be 1-inch minimum at all other locations. <br /> 30 <br /> 31 7-02.3(6)A2 Submittals <br /> 32 The Contractor shall submit Type 2E Working Drawings consisting of shop <br /> 33 drawings of the precast Structures with supporting design calculations. <br /> 34 <br /> 35 In addition to items 1 through 6 under shop drawing content requirements in <br /> 36 Section 6-02.3(28)A, the following shop drawing details shall be submitted: <br /> 37 <br /> 38 1. Footing and slab base details for PRCTSS. 1 <br /> 39 <br /> 40 2. Wingwall, headwall, and cutoff wall details. <br /> 41 <br /> 42 3. Erection and backfill procedure. <br /> 43 <br /> 44 4. Complete, site specific, itemized bar list for all steel reinforcement. <br /> 45 <br /> 46 If water is expected to be present in the excavation, or is found to be present <br /> 47 once excavation begins, the Contractor shall submit a Type 2 Working <br /> 48 Drawing consisting of a dewatering plan. <br /> 49 <br /> 50 For precast Structures with a span length greater than 20-feet (as defined in <br /> 51 Section 7-02.3(6)A1), the Working Drawing submittal shall include a load rating <br /> 52 prepared in accordance with the AASHTO Manual for Bridge Evaluation and <br /> I <br /> AMENDMENTS TO THE 2014 STANDARD SPECIFICATIONS BOOK <br /> Revised: 8/3/15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.