Laserfiche WebLink
I <br /> 1 WSDOT Bridge Design Manual LRFD (M23-50) Section 13. Soil pressures <br /> I 2 used shall include effects from the backfill material and compaction methods, <br /> 3 and shall be in accordance with the WSDOT Geotechnical Design Manual <br /> 4 (M46-03) and the geotechnical report prepared for the project. <br /> 5 <br /> I6 7-02.3(6)A3 Casting <br /> 7 Concrete shall conform to Section 6-02.3(28)B, with a 28-day compressive <br /> 8 strength as specified in the Working Drawings submittal. <br /> I9 <br /> 10 7-02.3(6)A4 Excavation and Bedding Preparation <br /> 11 All excavated material shall be disposed of in accordance with Section 2- <br /> I <br /> 12 09.3(1)D. <br /> 13 <br /> 14 If water is present within the excavation, the Contractor shall dewater the <br /> 1 15 excavated area in accordance with the dewatering plan Working Drawing <br /> 16 submittal before placing the bedding material. <br /> 17 <br /> I 18 The bedding for the precast Structure, consisting of the backfill elements <br /> 19 shown in the Plans, shall be placed and compacted in accordance with Section <br /> 20 7-08.3(1)C. <br /> 21 <br /> 1 22 7-02.3(6)B Precast Reinf. Conc. Three Sided Structures (PRCTSS) <br /> 23 7-02.3(6)B1 Design Criteria <br /> 24 In addition to the design criteria specified in Section 7-02.3(6)A1, the following <br /> I 25 shall apply. <br /> 26 <br /> 27 PRCTSS shall be precast rigid frames with monolithic upper corners internally <br /> I 28 reinforced for moment and shear resistance, except as otherwise noted. <br /> 29 Connecting separate and individually precast concrete panels together to form <br /> 30 the specified three sided frame geometry is acceptable provided the Structure <br /> I31 system provides moment and shear resistance from the lateral load from <br /> 32 backfill placed full width and full height at one side only of the PRCTSS. <br /> 33 <br /> I 34 7-02.3(6)62 Finishing <br /> 35 The Contractor shall mark the following information, using waterproof paint, on <br /> 36 the inside of a vertical leg of each precast section of the Structure: <br /> 37 <br /> I 38 1. PRCTSS span and rise dimensions, minimum and maximum design <br /> 39 earth cover dimensions, and vehicular live load for design (HL-93). <br /> 40 <br /> I 41 2. WSDOT Contract Number and date of fabrication. <br /> 42 <br /> 43 3. Name or trademark of the fabricator. <br /> I 44 <br /> 45 7-02.3(6)63 Erection <br /> 46 PRCTSS shall be erected and backfilled in accordance with the erection <br /> I 47 sequence specified in the processed Working Drawings, and the construction <br /> 48 equipment restrictions specified in Section 6-02.3(25)0. <br /> 49 <br /> 50 Adjacent precast sections shall be connected by welding the weld-tie anchors <br /> 51 in accordance with Section 6-02.3(25)0. After connecting the weld-tie anchors, <br /> 52 the Contractor shall paint the exposed metal surfaces with one coat of field <br /> I <br /> I AMENDMENTS TO THE 2014 STANDARD SPECIFICATIONS BOOK <br /> Revised: 8/3/15 <br />