Laserfiche WebLink
I <br /> 1 compound. Bolts shall be installed snug tight. The bearing seat and lid perimeter shall <br /> 2 be machined to allow a minimum of 75 percent of the bearing areas to be seated with a <br /> 3 tolerance of 0.0 to 0.005 inches measured with a feeler gage. The bearing area <br /> 4 percentage will be measured for each side of the lid as it bears on the frame. <br /> 5 <br /> 6 9-29.2(2) Standard Duty and Heavy-Duty Cable Vaults and Pull Boxes <br /> 7 This section's title is revised to read: <br /> 8 <br /> 9 Small Cable Vaults, Standard Duty Cable Vaults, Heavy-Duty Cable Vaults, <br /> 10 Standard Duty Pull Boxes, and Heavy-Duty Pull Boxes <br /> 11 <br /> 12 In the first paragraph, the first sentence is revised to read: <br /> 13 <br /> 14 Small, Standard Duty and Heavy-Duty Cable Vaults and Standard Duty and Heavy-Duty <br /> 15 Pull Boxes shall be constructed as a concrete box and as a concrete lid. <br /> 16 <br /> 17 9-29.2(2)A Standard Duty Cable Vaults and Pull Boxes <br /> 18 This section's title is revised to read: <br /> 19 <br /> 20 Small Cable Vaults, Standard Duty Cable Vaults, and Standard Duty Pull Boxes <br /> 21 <br /> 22 The first paragraph is revised to read: <br /> 23 <br /> 24 Small and Standard Duty Cable Vaults and Standard Duty Pull boxes shall be concrete <br /> 25 and have a minimum load rating of 22,500 pounds and be tested in accordance with <br /> 26 Section 9-29.2(1)C for concrete Standard Duty Junction Boxes. <br /> 27 <br /> 28 In the second paragraph, the first sentence is revised to read: <br /> 29 <br /> 30 Concrete for Small and Standard Duty Cable Vaults and Standard Duty Pull Boxes shall <br /> 31 have a minimum compressive strength of 4,000 psi. <br /> 32 <br /> 33 In the third paragraph, the first sentence is revised to read: <br /> 34 <br /> 35 All Small and Standard Duty Cable Vaults and Standard Duty Pull Boxes placed in <br /> 36 sidewalks, walkways, and shared-use paths shall have slip-resistant surfaces. <br /> 37 <br /> 38 The fourth paragraph (up until the colon) is revised to read: <br /> 39 <br /> 40 Materials for Small and Standard Duty Cable Vaults and Standard Duty Pull Boxes shall <br /> 41 conform to the following: I <br /> 42 <br /> 43 9-29.3 Fiber Optic Cable, Electrical Conductors, and Cable <br /> 44 This section is supplemented with the following new subsection: <br /> 45 <br /> 46 9-29.3(3) Wire Marking Sleeves <br /> 47 Wire marking sleeves shall be full-circle in design, non-adhesive, printable using an <br /> 48 indelible ink and shall fit snugly on the wire or cable. Marking sleeves shall be made <br /> 49 from a PVC or polyolefin, and provide permanent identification for wires and cables. <br /> 50 <br /> 51 9-29.3(2)A4 Location Wire <br /> 52 This section is revised to read: <br /> 1 <br /> AMENDMENTS TO THE 2014 STANDARD SPECIFICATIONS BOOK <br /> Revised: 8/3/15 <br />