2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 <br />Project Address Bray International Date 9/12/2014 <br />Lighting Alterations, Renovations & Building Additions For Building Department Use <br />� Less than 60% � 60% or more 0 Stand alone � Addition <br />Notes: <br />a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be <br />combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br />b. For retrofits and building additions, provide Space Types and gross interior areas in the <br />Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall <br />existing builidng, include all applicable existing Space Types and gross interior areas. <br />c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br />d. If less than 60% of existing fixtures will be replaced, provide tota/ existing lighting wattage <br />(prior to retrofit) in the space provided in the Maximum Allowed Lighting table. <br />Maximum Allowed Lighting Wattage <br />Location (plan #, owe ross n erior a s owe <br />room #) Space Type' Watts per ftz Area in ft2 (watts/ft2 x area) <br />#121 Office - Enclosed 1. 11 129 143 <br />Atrium** Enter Height: <br />Existing Lighting Enter Exist. Watts: <br />Retail Display Allowance from LTG-INT-DISPLAY <br />' Select Tab/e C405.5.2(2) category from drop down menu. <br />'" For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht., <br />above 40 feet is 0.02 W/ft. ht. <br />Pronosed Li�hting W <br />.i..� �r.�..�� � <br />room #) <br />21 <br />Fixture Description"" <br />2x4' lay in fluorescent fixtures (2) T-8, electronic ballast <br />Retail Display Lighting from LTG-INT-DISPLAY <br />Area Allowed Watts <br />Total 129 143 <br />Number of <br />Fixtures <br />Total Proposed Watts may not exceed Total Al/owed Watts for Interior Lighting <br />�" Include existing to remain lighting fixtures and exempt lighting equipment per notes be/ow. <br />Watts/ <br />Fixture <br />64 <br />Total Proposed <br />Proposed <br />64 <br />64 <br />Notes: <br />1. Include ALL proposed lighting fixtures. <br />2. For proposed Fixture Description, indicate fixture type, /amp type (e. g. T-8), number of /amps in the fixture, and bal/ast type (if included). For <br />track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. <br />3. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria <br />as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, <br />or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. <br />4. For lighting equipment eligible for exemption per C405. 5.1, note exception number and leave Watts/Fixture blank. <br />5. Document existing to remain fixtures in Proposed Lrghting table in the same manner as new fixtures. Identify as existing in fixture description. <br />6. If #NA appears in Retail Display cells, information on LTG-INT-DISPLAY is incomplete. <br />Interior Lighting Power Allowance COMPLIES <br />C� <br />