Laserfiche WebLink
�� SN�FlQ�IIS�I <br />HEALTH DISTRICT <br />WWW.SNOHD.ORG <br />July 1, 2015 <br />Aleisha Loring <br />� 4045 26th �;ve N E <br />Seattle, WA 98125 <br />Environmental Health Division <br />Subject: Proposed, Lazy Boy Brewing Co., 715 100th St SE #A1, Everett <br />Dear Ms. Loring: <br />_ ; �=---� �� � U �, ,�-" ( � � <br />U <br />1 1, <br />; ,,� ,gA�+� � $ 20i5 <br />i.� � � k p •. �. � �� � <br />�._, <br />� ._ "a;�, ,, <br />Your plans have been reviewed with the Rules and Requlations of the State Board of Health, and with <br />the policies of the Snohomish Health District. With the addition of the following conditions, the plans <br />are apF� cved. <br />1. The conditional approval o� the plans for Lazy Boy Brewing Co was based upon �he revised <br />plans subr�i$ted J�ne i9, 20i5, and �he menu ar,ci FEACCP submitted Jane�ary 2, 20'i5. A�y <br />cranges �o iii@S� i�@i'iiS WiiiiOUi j3i'ea�i��OYa{ fraen �hE Heai�r �is�rict v�ill uoid fihis approval. <br />2. The Health District operating permit application process must be completed prior to opening for <br />business. This facil�t}� �i[I be cl�ss�fie� as a!a� risk, foed estab[ishment �a�:th seats. <br />3. An indirect waste drain (an air gap) is required for the three-compartment sink, beer tap, <br />mechanical dishwashers, ice machine, pop dispenser, �+valk-in refrigeration, and any equipment in <br />which food or food contact equipment is placed. <br />4. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required <br />between the handwash sink (item #6) and the prep table (item #7), and between the handwash sink <br />(item #9) and the 3-compartment sink (item #8). <br />5. If splashguards (equipment, partitions and/or walls) are provided on both sides of a handwash sink <br />the distance between the splashguards must be at least 18 inches apart (shoulder width) to allow <br />proper access to the handwash sink. <br />6. Water heaters must be of sufficient size to completely fill two compartmenfs of the 3-compartment <br />sink with hot water and still be capable of providing at least 100°F water at the handwash sinks. <br />7. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br />must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br />inspection. This is required so that proper testing of the 15-second time requirement for hot water <br />availability can be completed. <br />8. All food service equipment, both new and used, must be listed by the National Sanitation <br />Foundation (NSF) or equivalent for its intended use, Used and new refrigeration must be capable of <br />holding food at temperature of 41 °F or below, <br />9. No mop sink is indicated on the floor plan. The installation of a mop sink is required. Disposal of <br />mop water via floor drains is not allowed. Prior to request for preoperational inspection, identify <br />the location of the mop sink. <br />10. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br />be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br />cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and <br />sealed so as to provide a smooth and cleanable surface. <br />� i. � ��e ceiling above the food preparation af�aS i71USi b2 i10(1-p2isGfat2Cl, nonabsorbent, smooth and <br />easily cleanable. <br />3020 Rucker Avenue, Suite 104 ■ Everett, WA 98201-3900 ■ tel: 425.339.5250 ■ fax: 425.339.5254 <br />