Laserfiche WebLink
i <br />w <br />J <br />J <br />Q <br />� <br />24'-0" <br />� � -r � <br />I II -� :i'nxr,'a �I <br />P <br />r--- �, <br />i I <br />� � PROPOSED GARAGE I <br />I � FOOTPRINT:576sf � I <br />� I � INCLUDING EAVES: 729sf � I <br />� I � SEE A2 FOR BASEMENT AND � II <br />� I 2nd FLOOR PLAN i I <br />� � <br />� � I <br />� � I <br />I II i I I <br />�I � � � <br />I I � <br />I I � <br />�------- ---------� � <br />I SEWER AND ABOVEGROUND <br />� POWER CONNECT FROM THE <br />ALLEY - LOCATE AND PROTECT <br />ALL SERVICES DURING <br />CONSTRUCTION <br />� <br />� �`�� ��� � ���.. �o• i�l• ilo <br />� — — � ___�� <br />CODE SUMMARY <br />ZONE R2-H <br />LOT SIZE 120'x50' = 6000sf <br />TAX ID #: 00437854402500 <br />LEGAL DESCRIPTION: <br />EVERETT DIV 1 PLAT OF BLOCK 544 <br />D-00 LOTS 24+25 <br />ELIZABETH <br />MAHER <br />ARCHITECT <br />0 <br />� <br />N <br />0 <br />N <br />28'-6" <br />EXISTING 12'x18' GARAGE <br />AND Al�fACHED CARPORT <br />TO BE DEMOLISHED <br />(SHOWN DASHED) <br />0 <br />� <br />10'-0' <br />33'-0" <br />— — — — — — — - � <br />;:�(,jJ�uvCU u� l�, �,ornpli,�nc.c witi� <br />�oning, SEPA and discretionar�,- ;��,�r,�� <br />�equirements. <br />/ <br />�:,v �� �Gf�—�nA� Date��Z��V� <br />'!�nning Dept. <br />_ _ _ _ PROPERTY LINE <br />PROJECT DESCRIPTION: <br />DEMOLITION OF EXISTING 1 CAR GARAGE AND CARPORT AND <br />CONSTRUCTION OF 24'x24' 2 CAR GARAGE WITH BONUS ROOM <br />ABOVE AND BASEMENT BELOW <br />SETBACKS: <br />SIDE: 5'-0" REQUIRED, 5'-0" MINIMUM PROVIDED <br />EAVES ALLOWED TO PROJECT 18" INTO SETBACK <br />REAR @ ALLEY: 0'-0" REQUIRED, 2'-0" PROVIDED <br />EIDEN GARAGE <br />Tom and Diana Eiden <br />2414 Baker Avenue, Everett WA 98201 <br />/'�NY CF?�;il�.a :� T� F..=�=�,C�L't� <br />PLANS F�R E3UILpfNG EXTERIOFt <br />REQUIRE P! h�dRf�i�a :�t�PT. APPROVA�. <br />Contact: -.l ►�1_��.��ti <br />������;�,'�_'[l d .. . !�..' _—'�_ u �1 '_—:�-_T_...��R <br /><. <br />BUILDING AREA AS PERCENTAGE OF LOT: <br />1031 sf + 576sf = 1607sf = 27% OF 6000sf LOT <br />BUILDING AREA: <br />ALLOWED: LESSER OF 15% OF LOT SIZE (900sfl, 75% <br />OF GROSS FLOOR AREA OF DWELLING (773sfl <br />OR 1000sf <br />PROPOSED: 576sf <br />SITE PLAN N <br />SCALE: 1/8" =1'-Q" <br />22'-6" <br />EXISTING FRONT YARD <br />0 <br />in <br />� <br />� <br />N <br />� <br />� <br />� <br />� <br />I <br />w <br />� <br />Z <br />L1J <br />Q <br />� � <br />IY <br />� m <br />WATER AND GAS � <br />CONNECT FROM BAKER � <br />AVE - LOCATE AND <br />PROTECT ALL SERVICES <br />DURING CONSTRUCTION <br />BUILDING HEIGHT: <br />ALLOWED: 15'-0", 20'-0" PER REVIEW PROCESS II <br />PROPOSED: 19'-10" <br />ROOF SLOPE: 6:12 REQUIRED AND PROVIDED <br />��,� � ^ � <br />� � ���-'wz.�, <br />:/ <br />March 30 <br />2°�° A1 <br />PERMIT <br />DRAWINGS <br />