September 24, 2015 <br />'UBL/C L�YO/�/�C.S <br />Joshua Scott <br />josh@I<ozdevelopment.com <br />RE: Owner: KOZ 1004 Broadway LLC <br />Job Address: 1004 Broadway <br />Plan Check No: B1509-OZ5 <br />Dear Mr. Scott, <br />In response to your application for a construction permit, your plans have been ex�mined and you are <br />advised that revisions may be necessary before a permit can be issued. Please review and respond to the <br />comments below. These comments address building issues only. Additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the 2012 <br />International Building Code (IBC), the Z012 International Fire Code (IFC), the 2012 International <br />Mechanical Code (IMC), and the 2012 International Energy Conservation (IECC), as amended by the <br />State of Washington and adopted by the city of Everett. The current IBC referenced standard for <br />accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal <br />ADA, FHA, and HUD regulations and standards, including the Fair Housing Accessibility Guidelines may be <br />more restrictive. <br />In order for the processing of your application to continue, it will be necessary to provide the <br />Building Division with two complete new sets of construction documents reflecting the <br />corrections requested. <br />Life Safetv <br />The south interior exit stairway includes a one-hour wall with window openings and a door <br />on the exterior side. IBC 1022.7 requires the windows within 10 feet of the exit stairway <br />openings to have a fire protection rating of not less than 3/4 hour. <br />Please provide stairway cross sections and detailing which include; <br />• Stair rise and run <br />• Landing configuration <br />• Structural support of 100 PSF. <br />• Materials and verification of one-hour rating (IBC 1009.9). <br />• Handrail dimensions <br />• Continuiry of the fire barrier enclosure through the floor assembly per IBC 707.5. <br />The south wall is required to be one-hour rated for exposure to fire from both sides. IBC <br />705.5. All other exterior walls are required to be one-hour rated for exposure to fire from the <br />inside. The wall assembly table should include this. <br />Please address and detail the parapet requirements of IBC 705.11 for the south wall. <br />Please provide detailing of the roof drains, in accordance with IBC 1503.4. <br />Please verify that the roof assembly will be class B in accordance with IBC 1505 and <br />2603.3.3. <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8882 <br />