My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 8TH FLOOR 2021-01-25
>
Address Records
>
COLBY AVE
>
1321
>
8TH FLOOR
>
1321 COLBY AVE 8TH FLOOR 2021-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2021 2:17:50 PM
Creation date
12/1/2016 1:21:20 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
8TH FLOOR
Notes
HOSPICE CARE CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 <br />Project Info ProjectAddress A-Wing -8th Floor Date 3/27/2015 <br />Compliance 1321 Colby Avenue For Building Department Use <br />forms do not <br />require a Everett, WA 98201 <br />password to Applicant Name: P�ovidence Re ional Medical Center - Everett <br />use. 9 <br />Instructional and Applicant Address: <br />calculating cells <br />are write- Applicant Phone: <br />Project Description New Building Addition Alteration Plans <br />Lighting Compliance Path • Lighting Power Density Calculations Total Building Performance <br />(If Total Building Performance then only LGT-CHK is required.) <br />Lighting Power Allowance � guilding Area Method Space-By-Space Method <br />Method Selection required to <br />enable LPA forms <br />Interior Lighting System Existing floorspace is being repurposed and renovated to create a Hospice wing on the 8th <br />DeSCTiption floor. Existing flourescent fixtures and local lighting controls will be replaced with new LED <br />fixtures and new local/automatic controls. <br />Briefly describe lighting <br />system type and features. <br />Additions and Change of Space Use (C101.4.3 & C101.4.4) <br />Addition area or Change of Space Use area complies with all applicable provisions as stand alone project <br />Addition area is combined with existing buiiding lighting systems to demonstrate compliance with all applicable <br />provisions per C101.4.3 <br />Provide Building Area Method (LTG-INT-BLD) or Space-By-Space Method (LTG-INT-SPACE) Compliance Form. Document maximum <br />allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting <br />controls per C405.2 and commissioning of lighting controls per C405.13. <br />Alterations, Renovations and Repairs (C101.4.3.1) <br />00% or more of luminaires in space replaced <br />Provide Building Area Method (LTG-INT-BLD) or Space-By-Space Method (LTG-INT-SPACE) Compliance Form. Document maximum <br />allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in <br />Proposed Wattage table. Retrofit and non-retrofit spaces shall be documented separately using multiple forms. <br />Less than 60% of luminaires in space replaced <br />Provide a separate Space-By-Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage <br />within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting <br />wattage in the Proposed Wattage table. <br />Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased <br />New wiring installed to serve added fixtures and/or fixtures relocated to new circuit <br />Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific <br />application controls (C405.2.3), and commissioning of lighting controls per C405.13 <br />New or moved lighting panel <br />Provide all applicable lighting controls as noted for New Winng, automatic time switch controls (C405.2.2.1), and commissioning of lighting <br />controls per C405.13. <br />Space is reconfigured - luminaires unchanged or moved only <br />Provide all app/icable lighting controls as noted for New Winng and commissioning of lighting controls per C405.13. <br />�lo changes are being made to the interior lighting and space use not changed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.