Laserfiche WebLink
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 8 R3 over 3 stories and all R1 Revised Jan 2014 <br />ProjectAddress A-Wing-8thFloor Date 3/27/2015 <br />Lighting Alterations, Renovations & Building Additions For Building Department Use <br />Less than 60% • 60% or more Stand alone Addition <br />Notes: <br />a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be <br />combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br />b. For retrofits and building additions, provide Building Area types and gross interior areas in the <br />Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall <br />existing builidng, include all applicable existing Building Area types and gross interior areas. <br />c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br />d. If /ess than 60% of existing fixtures will be replaced, use LTG-INT-SPACE form. <br />Maximum Allowed Lighting Wattage <br />Location (plan #, owe ross n ern <br />Building Area` room #, or ALL) Area Description Watts per ft2 Area in ftz <br />Hosoital ALL 8TH FLOOR HOSPICE SPACE 1. 20 14250 <br />* Select Table C405.5.2(1) Building Area from drop down menu. <br />Total I 14250 <br />(watts/ftZ x area) <br />17100 <br />Proposed Lighting Wattage <br />Location (plan #, Number of Watts/ Watts <br />Building Area* room #) Fixture Description'* Fixtures Fixture Proposed <br />Hospital L1 - RECESSED LED DOWNLIGHT 108 27 2916 <br />Hospital L2 - RECESSED LED DOWNLIGHT 17 39 663 <br />Hos ital L3 - RECESSED LED DOWNLIGHT - WALL 39 <br />p WA H <br />Hospital L4 - LED NIGHT LIGHT 16 4 64 <br />Hospital L5 - LED WALL MOUNTED TASK LIGHT 16 8 128 <br />Hospital L6 - WALL MOUNTED SINK LIGHT 8 30 240 <br />Hospital L7 - 4 FOOT LED LINEAR FIXTURE 32 21 666 <br />Hospital L8 - LED WALL SCONSE 15 18 270 <br />Hospital L9 - 24" LED UNDERCABINET FIXTURE 6 9 54 <br />Hospital L10 - 48" LED UNDERCABINET FIXTURE 6 30 180 <br />Hospital L11 - 2X2 RECESSED LED FIXTURE 21 <br />Hospital L12 - 2X4 RECESSED LED FIXTURE 32 43 1376 <br />Hospital L13 - 24" ROUND SURFACE MOUNTED LED 19 <br />FIXT RE <br />HospiWl L14 -8" ROUND PENDANT FIXTURE 11 27 297 <br />Hospital L15 - 8 FOOT LED LINEAR FIXTURE 32 42 1331 <br />Hospital T01 - TRACK LIGHTING (2 HEAD - 4 LF) 40 16 640 <br />Hospital T02 - TRACK LIGHTING (3 HEAD - 6 LF) 6 24 144 <br />Hospital T03- TRACK LIGHTING (4 HEAD - 8 LF) 4 32 128 <br />Hospital T04 - TRACK LIGHTING (5 HEAD - 10LF) 1 40 40 <br />Hospital TOS - TRACK LIGHTING (6 HEAD -12LF) 2 4 B 96 <br />' Se/ect Table C405.5.2(1) Building Area from drop down menu. <br />" Include existing to remain lighting and exempt lighting equipment per notes below. <br />Compliance by Building Area <br />Building Area <br />Confirtn a <br />Hospital __,_�;,,,, �„ <br />are <br />Total Allowed Total Proposed Interior Lighting Power <br />Watts Watts Allowance <br />Wa� 17100 9233 COMPLIES <br />Total 17100 9233 <br />