DESIGN CRITERIA: <br />1. THE STRUCTURAL DES!GN OF THiS PROJECT IS iN ACCORDANCE WITH <br />THE INTERNATIONAL BUILDING CODE 2012 WITH WASHINGTON STATE <br />6UIL�ING CODE AMENDMENTS (2012J <br />2. DESIGN LOADS: <br />DESIGN DATA FOR MARYSVILLE, WASHINGiON <br />-ROOF SM1OW LOAD N/A (NO' A ROOFiOP SOLUTION) <br />-BASIC wiND 5?EED 85 MPH <br />-WIN� E%POSURE C <br />-SEISMIC ZONE D <br />CONCRETE NOTES: <br />1. ALL CONCRE7E CONSTRUC'ION SHALL BE iN ACCORDANCE WITH <br />ACI-316. <br />2. CONCRETE SNALL BE MI%ED. PROPORTIONED, CONVEYED AND PL4CED IN <br />ACCORDANCE wITH CHAPTER 19 OF THE 2009 IBC wITH WASHWGTON <br />AMENDMENTS. SiRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE <br />AS FOLLOWS UNLE55 JiHERWISE NOT�D. <br />2B DAY STRENGIHS W�C RATIO MINIMUM CEMENT COMENT <br />(('c) PER CUBIC �ARD <br />2,SOJ P51 G.45 5 1/2 SACKS <br />CEMEN7 SI,ALL 9E ASiM C1J0, PORTLAND CEMENT TVP� II U.N.O. <br />3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE <br />FOR THE METHODS AND PROCE�URES OF CONCRETE PLACEMENi. <br />4. ALL CONCRETE WITH SURFACES EXPOSED i0 WEATHER SHALL BE <br />AIR-ENTRAINED WITH AN AIR-ENTRAINING AGENi CONFORMING TO ASTM <br />C260, C�94, C618, C989 AND C;017. CONCREiE ExPOSEC TO <br />FREEZING AND iHAW!NG WN.'�.L[ MO�ST SHA�� 9E AIR ENTRAIN�D IN <br />ACCORDANCE WITH ACI 318, SECIION 4.4.1. <br />5. REINFDRCING S1'_"EL SHALL CONFORN TO ASTM A615 (INCLUDING <br />SUPPLEMENi 51), GRADE 60, fy=60,0�� PSI. E%CEPilONS: ANY BARS <br />SPECIPICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, <br />ly=40,000 PSI. GRADE 60 REWFORCING BARS INDICATED ON DRAWINGS <br />TO 9E WEL�ED SHA�L CONFORM TO ASiAA A7�6 REINFORCING <br />COMPLYING WITH ASTM A675(57) MAY BE WELDED ONL� IF NATERIAL <br />PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING <br />PROCEDURES SPECIF!ED IN A.W.S. D14 ARE SUBMITTED. <br />6. REiNFORCING SiEEL SHALL BE DETAiLED (i�+ICLUDiNG HODKS nND <br />BENDS) IN ACCORDANCE WITH ACt 315 AND 318. LAP ALL <br />CONiINU0U5 REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A <br />MINIMUM OF 2'-0". PROVIDE CORNER BARS AT ALL WALL AND FOOIING <br />INTERSECTIONS. LAP CORNER BARS A1 LEAST 30 BAR �IAMETERS OR <br />A MINIMUM OF 2'-0". LAP ADJACENT MATS OF WE�DED WIRE FABRIC A <br />MINIMUM OF 8" AT SIDES AND E�CS. <br />7. WELDED WIRE FABRIC SHALL CONFORM TO ASiM A-�85. <br />8. SPIRAL REiNFORCEM_N1 SHALL BE PLAIN WIRE CONFORMING TO ASTM <br />A675, GRADE 60, (y=60,000 PSI <br />9. REINFORCING PARTIALLY EMBEDDED IN CONCRETE SNALL NOT BE FIELD <br />BENT UNLE55 SPEGFIC/LL� SO DETAILED OR APPROVED Bv THE <br />CONSULTANT. <br />10. CONCRETE PROTECTION (CDVER) FOR REINFORCING STEEL SHALL BE AS <br />FOLLOWS: <br />-FOOTINGS AND OTHER UNFORMED <br />SURFACES, EARTH FACE 3'� <br />-FORMED SURFACES EXPOSED (f{6 BARS OR LARGER) 2" <br />TO EARTH OR WEAIHER ((/5 BARS OR SMALLER) 1-1/2" <br />-SLABS AND WALLS (IMERIOR FACE) 3/4" <br />11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. <br />72. ANCHOR BOLTS TO CON�ORM 0 ASTM A307. <br />13. NON-SHRINK GROUT Sr;ALL BE FURN!SHED BY AN APPROVED <br />MANUFACTURER AND SHALL BE MIXED AND ?LACE� IN STRICI <br />ACCORDANCE WITH THE MANJFACTURER'S PUBLISHED RECOMMENDATIONS. <br />GR011i STRENGTH SHALL BE AT LEAST EOUAL Tp THE MA'�.ERIAL ON <br />WHICH IT IS PIy,CED (3,000 PS! MINIMUM). <br />14. ALL EXPA�S!ON ANCHORS �0 BE HILTI BRAND. ADHESNE ANCHORS <br />REOUIRE TESTING ?0 CONFIRM CAPACITv UNLFSS WAIVED 3Y ENGWEER <br />AND LOCAL JURISDICTION. <br />STRUCTURALSTEELNOTES: <br />1. SHOP DRAWINGS FOR STRl1CTURAL STcEL SHALL BE Sl18MITTEO TO AT&T AND THE <br />CONSULTqN� FOR REVIEW PRIOR 10 FABRICATiON. <br />2. SiRUCTURAL STEEL DESIGN, FABRICATION ANC EREC"IpN (IN��UD,�':G FIE! D WE�DING, <br />HIGH STRENGTH FlELD BOLTING. E%PANSION BOLTS, ANC THREADED EXPANSION <br />ANCHORS) SHALL 3E BAScD ON THE A.',.S.C. "SPE�IFiCAT10N �OR THE DESiGN, <br />FABRICATION, AND ERECTION OF SiRUCT',inA�_ SiE='�� FOR 3UILD.NGS�' LATEST ED�1iON. <br />SUPERVISION SHALL BE IN ACCORDANCE WITH 2O03 IBC CHAPiER 22, BY A OUALIFIED <br />7ESTING AGENCv DESIGNATED BY THE CONSULTAVT. iHE CONSULTANT SNALL BE <br />FURNISHED WITH A COPY OF ALL '�VSPECTION RFpORTS AND 1E5T RESULTS. <br />3. STRUCTURAL S7EEL SHALL CONFORM TO 1HE FOLLOWING REOWREMENTS: <br />4. iYPE OF uEMBER <br />A. WIDE FLANGE SHAPES ASTM A992, GRADE 50 <br />A. OTHER SHAPES, P�ATES. ANGLES, AND RODS ASTM A36, Fy 36 KSI <br />B. SPECIAL SHA?ES AND PLA'ES ASTM A572, Fy 50 KSI <br />C. PIPE COLUMNS /+SiM A53, Fy 35 K51 <br />D. SIRUCTURAL TUBING ASTM A504 Fy 46 KSI <br />E. ANCHOR BOLTS ASTM A307 <br />F. CONkEC'ION BOLTS ASiM A325 ?W:57-OFF-TVPE <br />5. HOT DIP GALVANIZE AFTER FABRICATION PER A123/A123M-00 ALL SiEEL E%POSED TO <br />WEATHER AND W:�=RE NOT"tD. <br />6. ALL WELDING SHALL BE IN CONFORIJ.ANC_ WI?F-. A.�..S.C. AND AWS 5'ANDARDS AND SHALL <br />BE PERFORMED BY ANSI/AWS D1.�. CERiiFIED WELDERS USiNG E70 %% ELECTRODES. <br />ONLY PREQUA'JFIED WELDS (AS DEFiN.D Bv AWS) Sh'ALL BE USED. WE�DWG OF GRADE <br />60 REINFORC�NG BARS (IF REOUIRED) 5'nALL B� �ERFORMED 1:51NG LOW HYDROGEN <br />ELECTRODES. WELDING OF GRADE 40 REINFORQNG BARS (IF RE�IIIRED) SHALL BE <br />PERFORMED 115ING E70 %% ELECTRODES. WELDiNG WITHIN 4" OF COLD BENDS IN <br />REINFORCING STEEL IS NOT PERMITiED. SEE REINFORCING NOTE FOR MATERIAL <br />REOUIREMEnlTS OF WELDED BA3S. <br />7. COLC-FORME� SiEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE <br />SHOW�� ON THE PLANS. ?ROVIDE MiNIMUM SECTION PROPERTIES INDICAiED. ALL <br />COL�-FORMED STEEL FRAMING SHALL CON=ORN 70 iHE q,LS.S. "SPECIFICAiION FOR <br />THE DESIGN OF COLD-FORAAED SiEEL SiRUCTURAL MEMBERS," <br />B. BOLiED CONNECTIONS SHALL USE BEARING TYPE ASTIA AJ25 BOLTS (3/4" DIA.) AND <br />SHALL HAVE A MINIMUM OF TV✓0 BOLTS UNLESS NOTcD OTHERWISE. <br />9. NON-STRIiCTURAL CONNECIIONS FOR STEEL GRATING MAv USE 5/8" DIA. ASTM A307 <br />BOLTS UNLESS NOTED OTHERWiSE. <br />7D. (UNLESS NDTED OTHERWISE). PREPARATION AND PAINTING SHALL BE IN ACCORDANCE <br />WITH 1HE SP�CIFICA'ION ANJ IN ACCORDANCE WITH THE PAINT MANUFACTURERS WRITTEN <br />INSTRUCTIONS. <br />1t ALL WELDS 10 BE 1/4" FILLEI UNLE55 NCTED OiHERW6E. <br />12. TOUCH UP ALL FIEL� DRILLING ,WELDING AND CL� SIiRfACES WiTI-'� 2 COATS OF <br />GALVACON (ZINC RICH PAINT� OR AP°ROVED EQLJAL. <br />TOWER/POLE NOTES: <br />1. VERIFICATION THAT iHE E%ISTING TOWER/POL� CAV S',1PPORT THE PRO?OSED ANTENNA <br />LOA�ING IS TO BE DONE BY OTHERS. <br />2 PROVIDE SUPPORTS FOR iHE ANTENNA COAx CAB�ES iA THE ELEVAT10N OF ALL INITIAL <br />AND iUiURE AN7"cNNAS. AN"ENNA COA% �ABLES ARE i0 BE SUPPpRTED AND <br />RESiRAINED AT THE CENiERS SU!TABLE TO THE MANU'ACTURER'S REOIJIREMENTS. <br />NOTE, <br />STRUCTURAL DRAWINGS AND NOTES SHALL TAK[ PREC[DENCE <br />OVER ALL DRAWINGS AND NO1E5. <br />SPECIAL INSPECTIONS: <br />1 <br />2 <br />3 <br />CONTRACTOR SHALL PROV'�DE �EOUIRE7 SPECIA�. INSP�CTIpNS PERFORMED B� AN <br />INDEPENDENT MSPECTOR, APPROVE� BY AT&i AND SriE LOCAL JURISDICTION, AS <br />REOUIRED B� THE 2009 19C SEC�iON �7G4 Wi=H WASHING�CN AMENDMENiS FOR THE <br />FOLLOWING: <br />A. CONCREiE' P30VIpE SPEC'�A��_ INSP=C ��.vn PE3 '�70<.a <br />�. TAKE CONCRETE 'EST SPECiM�NS DJRI�'v'G Tr� PL,4C!NG OF STRUCTURAL <br />REMFORCING AND SIRUCTURAL CONC3E7E. ExTERIOR AND WTERIOR SLABS ON <br />GRADE ARE NOT STaUCTURAL ELEM�N"S. <br />I�. vERiFv REINFORCiNG SIZE, PLACEMCNT, AND GRAD"c. <br />B. BOLTS AND ANCHORS IN CC4CR�E: <br />�. HOLDDOWN ANCNORS BOLiS' INSPECT SIZE, LENG�H, HOOK AND TIE TO <br />REINFORCING. <br />��. ADHESIVE ANCHORS: I�SPFCT HOLE SIZE, DEPTH, CLEANLINESS, AND <br />INSTALLATION PER MANUFACTURES RECOMIMENDATIONS. <br />C. WEL�ING: <br />�. VISUALLV INSPECT AL: Si3JC'�.URAL FIELD AND SHOP WELDING. <br />��. THE SPECIAL iNSPECTOR NEE� NOT TO BE CONTiNUOUSLY PRESENT DURING <br />WELD�.NG, �ROV�JED "HE MATERIALS, OUALIFICATIONS OF WELDING PROCE�URES <br />AND WELJERS ARE VER�FiED PRiOR TO T�.� STAR'. OF WORK; P�RIODiC <br />INSPECTIONS ARE AAADE 0� WORK IN aROGRE55; AND A VISUAL INSPECTION <br />OF ALL WELDS IS MADE AF"'ER C0�1P�ETION OR PRIOR TO SHIPMENT OF SHOP <br />WELDING. <br />PROVIDE SPECIAL INSPECTIONS FOR DiHER ITEMS NOTcD ON DRAWINGS TO CONFIRM <br />COMPLIANCE WITH CONTRACT DOCUMENTS. <br />TH�� SPECIAL INSPECTOR SHALL PROVIDE A �OPV O� THE REPORI TO 'HE OWNER, <br />ARCHIiECT, STRUCTURAL ENGiNEER, CONTRACTOR, AND BUiLDING OfFICIA�. <br />ABBREVIATED ROOF TOP SAFETY PROCEDURES <br />(WHEN APPLICABLE: <br />FALL PROTECiION MEINODS :1ND -0U'.PMt�7 ROOF TOP '�.NS�ALLATIO\'S. <br />1, FALL PROIECTION MEIHODS TO BE PER �EDERAL. STAiE, LOCAL, OSHA, AT&T AND <br />OWNER REOUIREMEkTS. <br />2 FOR WORK IS BEING PERFORA�ED WITHM 25' OF AN UNPROiECTED ROOF EDGE, THE <br />CONSTRUC110N SUPERVISOR SHALL DESIGn�A?E A TRAINED SAFETY MONITOR TD OBSERVE <br />1HE MOVENENTS Ar:D AC�IVITIES 0� TnE CONSTRUCTION WORKERS. <br />3. SAFEN MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I.E., BACKING UP <br />TOWARD A ROOF EDGE, EiC.) OR U�SAFE ACTIVITIES. iHE SAFEN MONITOR MU51 BE ON <br />THE SAME ROOF AND W'�THIN V��SUA� AND VERBAL D!STANCE OF THE CONSTRUC:ION <br />WORKERS. <br />4. CONS'RUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LE55 OF AN <br />UNPROTEC7ED ROOF EDGE, REOUIRES WORKERS TO USE SAFETY LWE. <br />5. SAFEIY LINE SHALL BE IAIivIMU�1 1/2" DIAMETER NYLON, WITH A NOMINAL TENSILE <br />STRENGTH OF 5400 LBS. <br />6. SAFETI' LINE SHALL BE A'ACHED TO A SUBSTANTIAL MEMBER OF THE STRUCTURE. <br />7. SAFETY LINE LENGTH SHALL BE SE1 ALLOWING CONSTRUCTION WORKER TO REACH EDGE <br />OF ROOF, BUT NOT BE1'OND. <br />B. SAFETI' BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS- <br />- �p �r F TH FA PR T CTION EOUIPMENT <br />9. N.ONTHLY SAFEiY INSPECiION AND NAMTEM1 M1..E 0 E LL 0 E <br />SHALL OCCUR B7 THE SAPE71' COMMITTEE REPRESENTATIVES, INCLUDING: <br />INSPECTION OF CONSTRUCTION AREA FOR HAZARDS <br />USE OF AN INSPECTION CHECKLIST <br />INTERVIEWING COWORKERS REGAR�ING SAFEiv �ONCERNS <br />REPORTING AND DOCUMENTiNG ANY HAZARDS <br />REPORTI�G HAZAR�S 70 THE SAFE1' COMM117EE FOR CONSIDERATION <br />POSTING RESULTS OF INSPECTION AND ANv AC�ION TAKEN <br />RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER <br />COWORKER 54FEiY REPR�SEN�AiNE <br />REFER 10 ROOFTOP WORK AREA SAFET' PROiOCOL NAiIONAL ASSOCIATION OF TOWER <br />ERECTORs z000 Pueucar;oN <br />REFERENCED OSHA REGULATION/STANDARDS SHALL BE REVIEWED BY ?OWER ERECTORS, <br />EOUIPMENT INSTALLERS, AND 'OWER/RDOF TOP CO�TRACi0R5/SUBCONTRACTORS <br />29 CFR 7926.500 - SCOPE, APPLICAiION, AND DEFINIilONS <br />29 CFR 1926.501 - DU1Y TO HAVE FALL PROTECiION <br />19 CFR 1926.502 - FALL �ROTECTION Sv5TEM5 CRITERIA AND PRACTICES <br />SYMBOLS AND ABBREVIATIONS <br />A/C AIR CONDITIONING HORZ HORIZOhiA� <br />AGL ABOVE FINISH GRA�E HR HOUR <br />APPROX APPRO%IN.ATEL" Hi HEIGHT <br />HVAC HEATING <br />BLDG BUILDING vENTILAiION <br />BLK BLOCKING AIR CONDITIONING <br />CLG CEI�ING ID INSIDE DIAMETER <br />CLR CLEAR IN WCH <br />CONC CONCRE"fE NFO INFORMATION <br />CONST CONSTRUC110N INSl1L INSULATION <br />CONT CONTINUOUS iNT INTERIOR <br />I�C INTERNATIONAL <br />DBL DOUBLE BUILDING CODE <br />DiA DiAu�E1ER <br />�IAG DIAGONAL LBS POUNDS <br />DN DOWN <br />DEi DETAIL MAX MAXIMUM <br />DWG DRAWING MECH MECHANICAL <br />MTL METAL <br />EA EACH MFR MANUFACIURE <br />ELEv ELEVA710N MGR �AANAGER <br />ELEC ELECTRICAL MIN MINIMUM <br />EO tOUAL MISC MISCELLANEOUS <br />EOUIP EOUIPMEN7 <br />E%T EXT[RIOR NA NOT APPLICABLE <br />NIC NOT IN CONTRAC7 <br />FIN FINISH NTS NOT TO SCALE <br />FLUOR FLOURESCENT <br />FLR FLOOR OC ON CENTER <br />FT FOOT OD OUTSIDE DIAMETER <br />GA GAUGE <br />GALV GALVAN2ED <br />GC GENERAI_ CONTRACIOR <br />GRN� GROUND <br />GYP BD GYPSUM WALL BOARD <br />- T- TELEPHONE <br />- P - POWER <br />- G GROUND wiRE <br />-COA% COAXIAL CABLE <br />� ANTENNA <br />� CENTERLINE <br />�E� E%ISIING <br />�N� NEW <br />� DETAIL Nl1M8ER <br />SHEET NUMBER <br />PLYWD PLVW00D <br />PROJ PROJECT <br />PROP PROP[RTY <br />PT PRESSURE iREATED <br />REQ REQUIRED <br />RM ROOM <br />RO ROUGN OPENING <br />SHT SHEET <br />SIM SIMILAR <br />SPEC SPECIFICATION <br />SF SQUARE F00T <br />SS STAINLESS STEEL <br />STL STEEL <br />STRUCT STRUCTl1RAL <br />STD STUD <br />SUSP SUSPENDED <br />THRu 1HROUGH <br />TNNG TINNED <br />iYP NPICAL <br />UNO UNLESS NOTED <br />OiHERWISE <br />VER7 VERTICAL <br />VIF VERIFv W FIELD <br />vy� WITH <br />�y�p WITHOUi <br />yyp WATER PROOF <br />� <br />U <br />L <br />Q <br />Z <br />O <br />� <br />J °' <br />QU <br />> <br />LL � <br />Cn <br />W � <br />�� <br />OJ <br />W °' <br />V � <br />1960� 40TH AVE. W., SUITE 304 <br />LVNNWOOD. WA 98036 <br />PHONE: (425) 740-6392 <br />FAX: (425) 224�6�4 <br />W W W -CAMPASSOG.COM <br />�ATE: '�2���.� �.. � <br />DRAWN BY: �A <br />CHECKED 8Y: _'\ <br />REVISIONS <br />z%,s is'Ico.;Kr�:i.v.� ;c. <br />.2��b��yl SSUE^ FOk <br />3= - - <br />2/69r�t6:�.�.�.,�< ;� �G> <br />REGISTERED <br />) ARCHI ECT <br />�UL NI <br />OF ASHINGTON <br />02I09R016 <br />WA6�9� <br />PORT GARD�EF <br />`'. 3�' . .?" 4N_ . ' <br />_� �- _ . J�T. ..��� <br />.J�=F- �-_� <br />GENERALNOTES <br />_, _� A.,'J�_ � <br />G-2.0 <br />JOB No. WA6299 <br />