Laserfiche WebLink
2.00-Year <br />3.33-Year <br />5-Year <br />10-Year <br />25-Year <br />50-Year <br />100-Year <br />101.529 <br />101.823 <br />102.009 <br />102.263 <br />102.502 <br />102.634 <br />102.673 <br />***********Groundwater Recharge Summary **'"*'"****�`*** <br />Recharge is computed as input to Perind Groundwater Plus Infiltration in Structures <br />Total Predeveloped Recharge During Simulation <br />Model Element Recharge Amount (ac-ft) <br />Subbasin: Big J <br />Total: <br />102.983 <br />102.983 <br />Total Post Developed Recharge During Simulation <br />Model Element Recharge Amount (ac-ft) <br />Subbasin: Subbasin 1 26.059 <br />Link: Detention Pond 0.000 <br />Total: <br />26.059 <br />Total Predevelopment Recharge is Greater than Post Developed <br />Average Recharge Per Year, (Number of Years= 158) <br />Predeveloped: 0.652 ac-ft/year, Post Developed: 0.165 ac-ft/year <br />*'"*"`*******Water Quality Facility Data *********"*** <br />----------------------SCENARIO: PREDEVELOPED <br />Number of Links: 0 <br />----------------------SCENARIO: POSTDEVELOPEQ <br />Number of Links: 1 <br />******�**� Link: Detention Pond <br />Basic Wet Pond Volume (91 % Exceedance): 2455. cu-ft <br />Computed Large Wet Pond Volume, 1.5*Basic Volume: 3682. cu-ft <br />Infiltration/Filtration Statistics-------------------- <br />Total Runoff Volume (ac-ft): 267.18 <br />Total Runoff Infiltrated (ac-ft): 0.00, 0.00% <br />Total Runoff Fiitered (ac-ft): 0.00, 0.00% <br />Percent Treated (Infiltrated+Filtered)/Total Volume: 0.00% <br />����*��**� <br />