My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1007 SE EVERETT MALL WAY 2017-05-15
>
Address Records
>
SE EVERETT MALL WAY
>
1007
>
1007 SE EVERETT MALL WAY 2017-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2017 11:36:40 AM
Creation date
12/5/2016 1:04:33 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1007
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
September 2, 2014 <br />• <br />PUBL/� L�YO/�/CS <br />Mr. Chris Boyer <br />C & L Drafting Services <br />7425 High Point Lane <br />Sacramento, CA 95842 <br />Owner: <br />Project: <br />Job Address: <br />Plan Check No: <br />Baldwin Brothers LLC <br />Tenant Improvement Arby's <br />1007 SE Everett Mall Way <br />B1408-050 <br />RE: Corrections Letter <br />Dear Mr. Boyer, <br />w <br />j ��►�t ���� �-r���a <br />� <br />�� � s/r� <br />�._.. _. � __�.�.��.� m� � <br />In response to the application for a building permit, the plans have been examined and you are <br />advised that revisions may be necessary before a permit can be issued. Please review and <br />respond to the comments below. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two complete new sets of construction <br />documents reflecting the corrections requested. Please include a response letter <br />which indicates how the corrections were resolved. <br />General <br />✓1. Please include the reference standard ICC Ai17.1-2009 in the list of code references. <br />�. The 2014 NEC was adopted by the department on March 1, 2013, to replace the current <br />2008 NEC standards and will become effective on July 1, 2014. <br />�3. CABO is not applicable in Washington State (general note 13 sheet 1). <br />��,y�� � Q 4. Please include a required plumbing fixture count in the code analysis. <br />�� ���- <br />R�,� � �" Egress <br />,/1. Raised character and Braille exit signs should be shown on the drawings, per IBC <br />section 1011.4. <br />Construction <br />' 1. Please clarify the scope of work on the reflected ceiling plan. All new? Lighting <br />replaced? <br />�qad �� bu�k �s� <br />���� �(2�The urinal wa�removed but not noted on the demolition drawings. A urinal is required <br />�����a �--�Jfor the men s facility per IC 2902.1.1.2, as amended by the State of Washington. Please <br />��p�✓ note that privacy screens are required per IBC1210.3. <br />�12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.