Laserfiche WebLink
• • • � e f - ' - � � <br />2012 Washington S1ate Energy Code Compliance Forms forCommercial Buildfngs Including R2 & R3 over 3 stones and all R1 Revised Jan 2014 <br />Project Address rue 21 -Everett Mail Date 4/1/2016 <br />The following information is necessary to check a permit application for compliance with ihe lighting, motor, and transformer requirements in the <br />Washington State Energy Code, Commercial Pravisions. <br />Applicability Location in Building Department <br />(yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br />L1GH71NG CONTROLS (Section C405.2) ' <br />r Indicate on plans the manual cantrol type 8� focations served; <br />Yes C40�.2.1.1 Manual interior _ <br />C4052.1.2 lighting controls Indicate of plans the 50% lighting load reduction method <br />provided or identify exception taken <br />Indicaie lighting system automatic shut-off capability- identify <br />lighting zone areas served on plans; <br />Automatic time <br />Yes C405.2.2.1 switch controls and �ndicate locations ot override switches on plans and the areas <br />override switching served, include area sq. ft.; _ <br />Indicate locations where autom atic shutoff is provided by other <br />methods (occupancy sensor, daylight controls, etc) <br />Yes C405,2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors <br />Daylighl zones - Indicate vertical fenestration primary and secondary daylight <br />xA C405.2,2.3 Vertical fenestratlon zone areas on plans, include sq. ft.; <br />and skylights Indicate skylight daylight zone areas on plans, include sq. ft. <br />Daylight zone �ndicate on plans the Iocatiorts served by daylight zone controls; <br />xn C405.2.2.3.2 controls <br />Indicate in plans the lighting Ioad reduction (dimming) method - <br />stepped or continuous dimming <br />Specific application Indicate on lans the locations served b s ecific a Ilcation <br />Yes C4Q5.2.3 lighting controls - lighting contols y p �p <br />General <br />Indicate lighting controi method for display and accent lighting, <br />and display case lighting; <br />Yes C405.2.3 - Display and accent <br />Items 1&2 lighting Indicate these fixtures are controlled independentlyfrom both <br />generet area li9hting and other I ighting applications within the <br />same space <br />C405.2.3 - Hotellmotel guest P�Ovide a Ifghting control device ai each guest room entryfor all <br />x7' permanently installed fixtures in guest room; <br />Item 3 rooms <br />fndicated whether lighting control is manual or automatic <br />xA C405.2.3 - Supplemental task Provide automatic shut-off vacancy controls for supptemental <br />Item 4 lighting task lighting, including under-shelf or under-cabinei lighting <br />Identify eligiblo non-visual applications and method of ligMing <br />control; <br />� C405.2.3 - Lighting iar non- ----- <br />Item 5 visual applications Indicate these fixtures are controlled independentl y from both <br />general area lighting and other I ighting appl ications within Ute <br />same space <br />Indicate lighting control method for lighting equipment for sale <br />C405.2.3- Lightingequipment ordemonsVation; <br />NA Item 6 for sale or Indicate these fixtures are controlied independentl y Trom bath � <br />demonstration general area lighting and other lighting applicaUons withln ihe <br />same space <br />If egress Ilghting power density Is greater than O.DSW /ftZ, <br />C405.2.3 - Means of egress indicate method pf autom atic shut-ofl during unoccupied <br />xA periods; <br />ltem 7 lighting <br />Identify on plans the egress fixtures that functian as both normaf <br />and emergency means of egress illumination <br />C405.10 Cooler and freezer Provide vacancy device or frmer to tum off fixtures within 15 <br />NA minutes of unoccupancy for cooler and ireezer lighting fxtures <br />C405.11 lighting with lamp effcacy less than 40 lumens per watt <br />NA C405.2A Extenor lighting fndicate on exterior lighting plans the automatic IighUng control <br />controls method and locations served <br />E�erior building Provide motion sensor controls for building grounds fixtures <br />NA C405.6.1 grounds lighting rated at greater than 100 w atts with lamp efficacy less ihan 60 <br />controls lumens, or identify exceplion taken <br />Identi(y applicable commissioning documentation requirements <br />per Section C408 or eligibility for exception; <br />Yes C408.3 Lighting system Provide wnrien procedures for functional testing of all automatic <br />functional testing controls and descnbe lhe expected system response; <br />Identify in construction documents the party responsible for <br />functional tosiing of automatic lighting controis <br />WTERIOR LIGHTING POWER & EFFICACY Sections C405.5, C405.10, C405.11} <br />